North Star M165938N Gas Hook-up Installation for Natural Gas or LPG if needed, Propane LPG

Page 14

Installation / Initial Set-Up

3. Gas Hook-up Installation for Natural Gas or LPG (if needed)

You can power this generator with gasoline, natural gas (NG), or propane (LP) gas. The generator is designed so that it is easy to switch between fuel sources. However, there are special initial hook-up requirements for natural gas and propane:

WARNING:

If you choose to operate the generator on NG or LPG, you must have the fuel line system installed by a certified gas technician.

Specific requirements for each type of hook-up are given below:

Natural Gas (NG)

Contact your gas utility company for installation of a natural gas hook-

Hook-up

up for the generator.

 

WARNING:

 

Natural gas is a highly explosive gas. All natural gas hook-ups must

 

be completed by trained personnel from your natural gas utility

 

company and inspected as required by your local building code.

This product is designed to operate on NG at a gas pressure range of 4 to 6 ounces per square inch (7”-11” of water column) and requires a minimum NG flow rate of 3.25 CFM.

The standard gas pressure normally delivered to your building by your utility company may be higher or lower than the required 4-6 ounces per square inch (7”-11” of water column):

 

o If your standard delivery pressure exceeds 4-6 ounces per square

 

inch (7”-11” water column), you will need a pressure-reducing

 

regulator installed. Excessive gas pressure will permanently

 

damage this product and void the warranty if the generator is not

 

installed correctly with a pressure-reducing regulator as needed.

 

Note: The regulator supplied with this product is NOT a

 

pressure-reducing regulator, but one can be supplied

 

and installed by your gas utility technician at the time

 

of fuel system hook-up.

 

o If your standard delivery pressure is lower than 4-6 ounces per

 

square inch (7”-11” water column), you will need changes to your

 

natural gas service to provide elevated delivery pressure. In

 

addition you will need to have a pressure-reducing devices installed

Propane (LPG)

for your other natural gas appliances.

Contact your local propane supplier to install a propane fuel system for

Hook-up

the generator.

 

WARNING:

 

LPG is a highly explosive gas. A qualified propane technician must

 

make the valve and hose connection between the propane tank and

 

generator in accordance with all local regulations and electrical codes.

 

All LPG hook-ups should be completed by trained personnel from

 

propane supplier and inspected as required by your local building

 

code.

14

Image 14
Contents Any Questions, Comments, Problems, or Parts Orders Watt Continuous 8,000 Watt Surge CapacityHazard Signal Word Definitions Table of Contents About Your Generator About Your GeneratorAbout Your Generator cont’d Read this ManualSpecifications Specifications Item #165938NSafety Label Locations Item #165938N Part numbers DescriptionMachine Component Identification Item #165938N DescriptionReference Guide Reference 9 Vibration Power Load Planning & Management Example conversion to wattsPower Load Planning & Management cont’d ExampleUnpacking & Delivery Inspection Installation / Initial Set-UpPlanning the Power Load Hook-up Generator Gas Hook-up Installation for Natural Gas or LPG if neededPropane LPG Installation / Initial Set-Up Set-up either as a Building BACK-UP or Portable Power Source Nema Current/Power Maximum Extension Cord Length Monoxide exhaust Select a Suitable SiteOutdoors only Away from all air intakesStructure allow at least a 7’ clearance Grounding the generator Battery Installation General safety rules for operation OperationOperation cont’d Operation cont’d Check the oil level using the dipstick and add oil as needed Preparing for OperationGenerator on gasoline Start LPG/NG supply If using Natural GasOperation cont’d Using LP/NG To start engine using LP or Natural Gas Starting the EngineTo start engine using gasoline Checking Generator Output Connecting Loads Stopping Switching Fuels during operationStop the engine using the following steps When you are finished using the generator, you must Storage & ExerciseOperation cont’d Maintenance & Repair Maintenance & RepairMaintenance & Repair cont’d Troubleshooting TroubleshootingBattery Safety Summary of Important Safety Information for OperationSafety Installation & Set-up GeneralKnow how to operate Safety Before UseInstallation / Initial Set-up Safety Propane & Natural Gas Safety Safety During UseGasoline Safety Personal protective equipmentSummary of Important Safety Information for Operation cont’d Safety After use Safety Inspection/MaintenanceGenerator Exploded View Rev- N Diag # Description Qty Wiring Diagram Rev- N Generator Head Exploded View Rev- N Item # Description Qty