Propane Cylinder Installation: Set cylinder into hole in bottom shelf. Tighten strap over cylinder to secure it in place.

Loop Strapping through slots in bottom shelf and secure over top of propane tank as illustrated

Cylinder Connection: Ensure the gas regulator hose is kink free. Remove the cap from the cylinder fuel valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise. Do not use tools. Leak test all joints prior to using the patio torch. A leak test must be performed annually and each time a cylinder is hooked up or if a part of the gas system is replaced.

If this torch is to be connected directly to a house propane gas supply line, follow the instructions for the natural gas hook-up. Ensure that the supply pressure is 11 inches water column.

Natural Gas Hook-Up: These connections must be made by a licensed gas fitter. This natural gas patio torch is supplied with a gas supply hose (complete with a quick disconnect) designed for natural gas and certified for outdoor use. The patio torch is designed to operate at an inlet pressure of 7 inches water column. Piping and valves upstream of the quick disconnect are not supplied. The installation must comply with CAN B149.1 Natural Gas and Propane installation code in Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be sufficient to supply this 31,000 BTU/hr patio torch.

The quick disconnect must not be installed in an upward direction and a readily accessible manual shut-off valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The flared end of the hose must be connected to the fitting on the end of the control valve as illustrated in the Natural Gas Hose Attachment diagram. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints prior to using the gas torch.

WARNING!

The installation must be performed by a licensed gas fitter, and all connections must be leak tested before operating the patio torch.

Ensure all hose connections are tightened using two wrenches. Do not use Teflon tape or pipe dope on any hose connection.

Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a fire.

Leak test all the connections using a soap and water solution as per the leak testing instructions found in the manual.

The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 0.5 psi (3.5 kPa).

The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

www.napoleongrills.com

Image 5
Contents Bellagio Commercial GAS Patio Torch PTH31GT Conditions And Limitations Napoleon Patio Torch Presidents WarrantySafe Operating Practices Gas Hook-Up Instructions Propane Cylinder SpecificationsGeneral Information Page Leak Testing Instructions Lighting Holes Lighting InstructionsOperating The Patio Torch Maintenance / Cleaning Instructions Problem Possible Causes Solution TroubleshootingPour Commencer Getting StartedFront 16 X M5 X M5 X Silicone ring must be in place prior to operating the torch 12 X M5 X Rubber Bushing Anneau DE Protection EN Caoutchouc Leak Testing Instructions Item # Description Qty Picture Comments Parts ListParts List Warranty Information Ordering Replacement PartsAccessories & Parts Order Form