Outdoor Installation

Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes.

The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation and will result in short circuits and grounding.

Foreign materials such as dust, sand, lint and abrasive materials have a tendency to cause excessive wear to engine and alternator parts.

CAUTION - EXHAUST HAZARD

Pay close attention to ventilation when operating the generator inside tunnels and caves. The engine exhaust contains noxious elements. Engine exhaust must be routed to a ventilated area.

Indoor Installation

Exhaust gases from diesel engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside.The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure which will cause the engine to heat excessively and possibly burn the valves.

Mounting

The generator must be mounted on a solid foundation (such as concrete) and set firmly on the foundation to isolate vibration of the generator when it is running. The generator must set at least 6 inches above the floor or grade level (in accordance to NFPA 110, Chapter 5-4.1). DO NOT remove the metal skids on the bottom of the generator. They are to resist damage to the bottom of the generator and to maintain alignment.

TLG-12SPX4 — INSTALLATION

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

NEC articles 250-64(b) and 250-66 set the following grounding requirements:

1.Use one of the following wire types to connect the generator to earth ground.

a.Copper - 10 AWG (5.3 mm2) or larger.

b.Aluminum - 8 AWG (8.4 mm2) or larger.

2.When grounding the generator (Figure 2) connect the ground cable between the lock washer and the nut on the generator and tighten the nut fully. Connect the other end of the ground cable to earth ground.

3.NEC article 250-52(c) specifies that the earth ground rod should be buried aminimum of 8 ft. into the ground.

When connecting the generator

NOTEto any buildings electrical system ALWAYS consult with a licensed electrician.

PAGE 16 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV. #1 (12/17/09)

Image 16
Contents Model TLG-12SPX4 Diesel engine exhaust and some TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 Table of Contents Parts Ordering Procedures Ordering parts has never been easierTLG-12SPX4 Specifications Dimensions Dimension ft. mmTLG-12SPX4 Safety Message Alert Symbols Hazard SymbolsTLG-12SPX4 Safety Message Alert Symbols General Safety TLG-12SPX4 Rules for Safe OperationInjury People Carbon monoxide gasTLG-12SPX4 Rules for Safe Operation Battery Safety TLG-12SPX4 Rules for Safe OperationDeath Towing and Transporting Safety Guidelines section in this manualTLG-12SPX4 Installation TLG-12SPX4 Installation Outdoor InstallationIndoor Installation MountingTLG-12SPX4 General Information TLG-12SPX4 Major Components TLG-12SPX4 Generator Control Panel TLG-12SPX4 Generator Control Panel TLG-12SPX4 Output Terminal Panel Familiarization Output Terminal Familiarization120VAC Gfci Receptacle TLG-12SPX4 Output Terminal Panel FamiliarizationL5-30RTwist Lock 120VAC Receptacle Option Connecting Loads TLG-12SPX4 Output Terminal Panel FamiliarizationSingle Phase Load TLG-12SPX4 Load APPLICATION/MAXIMUM AmperageGenerator Amperage Rated Voltage Maximum AmpsTLG-12SPX4 Setup Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure RefuelingCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Battery Cable InstallationWiring AlternatorBefore Starting Engines exhaust contains harmful emissionsDirect exhaust away from nearby personnel Close all engine enclosure doors FigureTLG-12SPX4 Generator START-UP Procedure Manual Emergency Shutdown Procedure Normal Shutdown ProcedurePlace both the main circuit breaker to the OFF position TLG-12SPX4 Maintenance Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterBrake Adjustment BrakesCheck the wheel and drum for free rotation Hydraulic Surge BrakesTLG-12SPX4 -TRAILER Maintenance Tires/Wheels/Lug NutsTireWear/Inflation SuspensionLug Nut Torque Requirements TLG-12SPX4 -TRAILER MaintenanceStart all wheel lug nuts by hand TLG-12SPX4 Generatorwiring Diagram Generator Wiring DiagramTLG-12SPX4 Enginewiring Diagram TLG-12SPX4 -TROUBLESHOOTING Engine Engine TroubleshootingTLG-12SPX4 -TROUBLESHOOTING Engine TLG-12SPX4 -TROUBLESHOOTING Generator Sample Parts List TLG 12SPX4 Explanation of Code in Remarks ColumnTLG 12SPX4 Suggested Spare Parts Part number on this Suggested Spare Parts listDescription TLG 12SPX4 Generator Assy D4110000203 0601820037S10VB60 0601822638TLG 12SPX4 Control Panel Assy DB0223001503 00218060300601800408 Frequency METER, 45~65 Hz 0601805745 060180028148 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 B0354400003 303214300444A 0207004000 0601815109TLG 12SPX4 Engine and Radiator Assy B0924200144 17472970111585332435 B030320200452 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 0016906025 01936008000314900350 0314900430TLG 12SPX4 Battery Assy 0165105524 87222510047552253004 7872251004TLG 12SPX4 Muffler Assy B0331000503 B03330023031526312371 D9304000004TLG 12SPX4 Fueltank Assy B0363000103 A9924800024E2924300214 E1924300184TLG 12SPX4 Enclosure Assy B0413001302 B0493000703B0414300103 B049700000462 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 0021806016 34A 00300060000845047204 35A 0845045004TLG 12SPX4 Rubber Seals Assy 0314900690 03149005600314900920 0229400590TLG 12SPX4 Name Plate Assy 7440611013 1742B6390671104 237768 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 B0560100004 B0560100604B0560100204 B0560100304Terms and Conditions of Sale Parts Freight PolicyTLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 HERE’S HOW to GET Help

TLG-12SPX4 specifications

The Multiquip TLG-12SPX4 is a premier choice in the realm of portable generators, designed to deliver reliable power for a variety of applications. As the demand for efficient and mobile power sources continues to rise, the TLG-12SPX4 stands out with a host of innovative features and advanced technologies that cater to both professional and recreational uses.

One of the main features of the TLG-12SPX4 is its robust power output. The generator is equipped with a powerful engine capable of producing up to 12,000 watts of peak power. This makes it suitable for construction sites, outdoor events, and emergency situations, where dependable electricity is crucial. The generator’s impressive output ensures that multiple tools and appliances can operate simultaneously without any drops in performance.

In terms of design, the Multiquip TLG-12SPX4 boasts a durable and heavy-duty frame that is built to withstand the rigors of job sites and harsh weather conditions. The unit is also equipped with a weather-resistant cover to protect its components from the elements, ensuring longevity and reliability. Its compact size and wheel kit allow for easy transport, making it a favored choice for contractors and outdoor enthusiasts alike.

The technology embedded in the TLG-12SPX4 enhances its user-friendliness and efficiency. It features a digital display that provides real-time information such as voltage output, power consumption, and runtime. This allows users to monitor their power usage closely. Additionally, the electric start system simplifies operation, eliminating the need for tedious manual starting procedures.

Safety is another paramount aspect of the TLG-12SPX4 design. The unit comes equipped with automatic low-oil shutdown technology, which protects the engine from damage by automatically shutting off when oil levels are critically low. Circuit breakers are also integrated to prevent overloads, ensuring safe operation for users.

In conclusion, the Multiquip TLG-12SPX4 is a powerful, durable, and user-friendly generator that exemplifies what modern portable power solutions should provide. With its impressive output, robust construction, advanced technologies, and thoughtful safety features, it stands ready to meet the diverse power needs of its users, whether on a job site or in a home emergency situation. Its combination of efficiency and reliability makes it a top choice among generators in its class.