Multiquip TLG-12SPX4 Air Removal, Check Oil Level, Replacing Oil Filter, Replacing Fuel Filter

Page 33

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure. See the KUBOTA Engine Manual for details.

To restart after running out of fuel, turn the switch to the “ON” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 12.

Replacing Oil Filter

Remove the old oil filter.

Apply a film of oil to the gasket on the new oil filter.

Install the new oil filter.

After the oil cartridge has been replaced, the engine oil will drop slightly. Run the engine for a while and check for leaks before adding more oil if needed. Clean excessive oil from engine.

Cleaning the Fuel Strainer

Clean the fuel strainer if it contains dust or water. Remove dust or water in the strainer cap and wash it in gasoline. Securely fasten the fuel strainer cap so that fuel will not leak. Check the fuel strainer every 200 hours of operation or once a month.

Replacing Fuel Filter

Replace the fuel filter cartridge with new one every 500 hours or so.

Loosen the drain plug at the lower top of the fuel filter. Drain the fuel in the fuel body together with the mixed water. DO NOT spill the fuel during disassembly.

Vent any air.

TLG-12SPX4 — MAINTENANCE

Flushing Out Radiator and Replacing Coolant

Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant.Open the radiator cap while draining. Remove the overflow tank and drain.

Check hoses for softening and kinks. Check clamps for signs of leakage.

Flush the radiator by running clean tap water through radiator until signs of rust and dirt are removed. DO NOT clean radiator core with any objects, such as a screwdriver.

Tighten both cocks and replace the overflow tank.

Replace with coolant as recommended by the engine manufaturer.

Close radiator cap tightly.

WARNING - BURN HAZARDS

Allow engine to cool when flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam.

Generator Storage

For longe term storage of the generator the following is recommended:

Fill the fuel tank completely. Treat with a fuel stabilizer if necessary.

Completely drain the oil from the crankcase and refill if necessary with fresh oil.

Clean the entire generator, internal and external.

Cover the generating set and store in a clean, dry place.

Disconnect the battery.

Make sure engine coolant is at proper level.

If generator is mounted on a trailer, jack trailer up and place on blocks so tires do not touch the ground or block and completely remove the tires.

TLG-12SPX4— OPERATION AND PARTS MANUAL — REV. #1 (12/17/09) — PAGE 33

Image 33
Contents Model TLG-12SPX4 Diesel engine exhaust and some TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresTLG-12SPX4 Specifications Dimension ft. mm DimensionsHazard Symbols TLG-12SPX4 Safety Message Alert SymbolsTLG-12SPX4 Safety Message Alert Symbols TLG-12SPX4 Rules for Safe Operation General SafetyInjury People Carbon monoxide gasTLG-12SPX4 Rules for Safe Operation TLG-12SPX4 Rules for Safe Operation Battery SafetyDeath Guidelines section in this manual Towing and Transporting SafetyTLG-12SPX4 Installation Outdoor Installation TLG-12SPX4 InstallationIndoor Installation MountingTLG-12SPX4 General Information TLG-12SPX4 Major Components TLG-12SPX4 Generator Control Panel TLG-12SPX4 Generator Control Panel Output Terminal Familiarization TLG-12SPX4 Output Terminal Panel FamiliarizationTLG-12SPX4 Output Terminal Panel Familiarization 120VAC Gfci ReceptacleL5-30RTwist Lock 120VAC Receptacle Option TLG-12SPX4 Output Terminal Panel Familiarization Connecting LoadsTLG-12SPX4 Load APPLICATION/MAXIMUM Amperage Single Phase LoadGenerator Amperage Rated Voltage Maximum AmpsCircuit Breakers TLG-12SPX4 SetupLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorEngines exhaust contains harmful emissions Before StartingDirect exhaust away from nearby personnel Close all engine enclosure doors FigureTLG-12SPX4 Generator START-UP Procedure Manual Normal Shutdown Procedure Emergency Shutdown ProcedurePlace both the main circuit breaker to the OFF position TLG-12SPX4 Maintenance Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterBrakes Brake AdjustmentCheck the wheel and drum for free rotation Hydraulic Surge BrakesTires/Wheels/Lug Nuts TLG-12SPX4 -TRAILER MaintenanceTireWear/Inflation SuspensionTLG-12SPX4 -TRAILER Maintenance Lug Nut Torque RequirementsStart all wheel lug nuts by hand Generator Wiring Diagram TLG-12SPX4 Generatorwiring DiagramTLG-12SPX4 Enginewiring Diagram Engine Troubleshooting TLG-12SPX4 -TROUBLESHOOTING EngineTLG-12SPX4 -TROUBLESHOOTING Engine TLG-12SPX4 -TROUBLESHOOTING Generator TLG 12SPX4 Explanation of Code in Remarks Column Sample Parts ListPart number on this Suggested Spare Parts list TLG 12SPX4 Suggested Spare PartsDescription TLG 12SPX4 Generator Assy 0601820037 D4110000203S10VB60 0601822638TLG 12SPX4 Control Panel Assy 0021806030 DB02230015030601800408 Frequency METER, 45~65 Hz 0601805745 060180028148 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 3032143004 B035440000344A 0207004000 0601815109TLG 12SPX4 Engine and Radiator Assy 1747297011 B09242001441585332435 B030320200452 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 0193600800 00169060250314900350 0314900430TLG 12SPX4 Battery Assy 8722251004 01651055247552253004 7872251004TLG 12SPX4 Muffler Assy B0333002303 B03310005031526312371 D9304000004TLG 12SPX4 Fueltank Assy A9924800024 B0363000103E2924300214 E1924300184TLG 12SPX4 Enclosure Assy B0493000703 B0413001302B0414300103 B049700000462 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 34A 0030006000 00218060160845047204 35A 0845045004TLG 12SPX4 Rubber Seals Assy 0314900560 03149006900314900920 0229400590TLG 12SPX4 Name Plate Assy 1742B 74406110136390671104 237768 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 B0560100604 B0560100004B0560100204 B0560100304Freight Policy Terms and Conditions of Sale PartsTLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 HERE’S HOW to GET Help

TLG-12SPX4 specifications

The Multiquip TLG-12SPX4 is a premier choice in the realm of portable generators, designed to deliver reliable power for a variety of applications. As the demand for efficient and mobile power sources continues to rise, the TLG-12SPX4 stands out with a host of innovative features and advanced technologies that cater to both professional and recreational uses.

One of the main features of the TLG-12SPX4 is its robust power output. The generator is equipped with a powerful engine capable of producing up to 12,000 watts of peak power. This makes it suitable for construction sites, outdoor events, and emergency situations, where dependable electricity is crucial. The generator’s impressive output ensures that multiple tools and appliances can operate simultaneously without any drops in performance.

In terms of design, the Multiquip TLG-12SPX4 boasts a durable and heavy-duty frame that is built to withstand the rigors of job sites and harsh weather conditions. The unit is also equipped with a weather-resistant cover to protect its components from the elements, ensuring longevity and reliability. Its compact size and wheel kit allow for easy transport, making it a favored choice for contractors and outdoor enthusiasts alike.

The technology embedded in the TLG-12SPX4 enhances its user-friendliness and efficiency. It features a digital display that provides real-time information such as voltage output, power consumption, and runtime. This allows users to monitor their power usage closely. Additionally, the electric start system simplifies operation, eliminating the need for tedious manual starting procedures.

Safety is another paramount aspect of the TLG-12SPX4 design. The unit comes equipped with automatic low-oil shutdown technology, which protects the engine from damage by automatically shutting off when oil levels are critically low. Circuit breakers are also integrated to prevent overloads, ensuring safe operation for users.

In conclusion, the Multiquip TLG-12SPX4 is a powerful, durable, and user-friendly generator that exemplifies what modern portable power solutions should provide. With its impressive output, robust construction, advanced technologies, and thoughtful safety features, it stands ready to meet the diverse power needs of its users, whether on a job site or in a home emergency situation. Its combination of efficiency and reliability makes it a top choice among generators in its class.