Multiquip operation manual TLG-12SPX4 -TRAILER Maintenance, Lug Nut Torque Requirements

Page 36

TLG-12SPX4 —TRAILER MAINTENANCE

Lug Nut Torque Requirements

It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows:

1.Start all wheel lug nuts by hand.

2.Torque all lug nuts in sequence (see Figure 34). DO NOT torque the wheel lug nuts all the way down.Tighten each lug nut in 3 separate passes as defined by Table 15.

3.After first road use, retorque all lug nuts in sequence. Check all wheel lug nuts periodically.

Table 15. Tire Torque Requirements

Wheel Size

First Pass

Second Pass

Third Pass

 

FT-LBS

FT-LBS

FT-LBS

 

 

 

 

12"

20-25

35-40

50-65

 

 

 

 

13"

20-25

35-40

50-65

 

 

 

 

14"

20-25

50-60

90-120

 

 

 

 

15"

20-25

50-60

90-120

 

 

 

 

16"

20-25

50-60

90-120

 

 

 

 

Figure 34. Wheel Lug Nuts

Tightening Sequence

NOTE

NEVER use an pneumatic air

 

gun to tighten wheel lug nuts.

PAGE 36 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV. #1 (12/17/09)

Image 36
Contents Model TLG-12SPX4 Diesel engine exhaust and some TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 Table of Contents Parts Ordering Procedures Ordering parts has never been easierTLG-12SPX4 Specifications Dimensions Dimension ft. mmTLG-12SPX4 Safety Message Alert Symbols Hazard SymbolsTLG-12SPX4 Safety Message Alert Symbols General Safety TLG-12SPX4 Rules for Safe OperationInjury People Carbon monoxide gasTLG-12SPX4 Rules for Safe Operation Battery Safety TLG-12SPX4 Rules for Safe OperationDeath Towing and Transporting Safety Guidelines section in this manualTLG-12SPX4 Installation TLG-12SPX4 Installation Outdoor InstallationIndoor Installation MountingTLG-12SPX4 General Information TLG-12SPX4 Major Components TLG-12SPX4 Generator Control Panel TLG-12SPX4 Generator Control Panel TLG-12SPX4 Output Terminal Panel Familiarization Output Terminal FamiliarizationTLG-12SPX4 Output Terminal Panel Familiarization 120VAC Gfci ReceptacleL5-30RTwist Lock 120VAC Receptacle Option Connecting Loads TLG-12SPX4 Output Terminal Panel FamiliarizationSingle Phase Load TLG-12SPX4 Load APPLICATION/MAXIMUM AmperageGenerator Amperage Rated Voltage Maximum AmpsTLG-12SPX4 Setup Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure RefuelingCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Battery Cable InstallationWiring AlternatorBefore Starting Engines exhaust contains harmful emissionsDirect exhaust away from nearby personnel Close all engine enclosure doors FigureTLG-12SPX4 Generator START-UP Procedure Manual Normal Shutdown Procedure Emergency Shutdown ProcedurePlace both the main circuit breaker to the OFF position TLG-12SPX4 Maintenance Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterBrake Adjustment BrakesCheck the wheel and drum for free rotation Hydraulic Surge BrakesTLG-12SPX4 -TRAILER Maintenance Tires/Wheels/Lug NutsTireWear/Inflation SuspensionTLG-12SPX4 -TRAILER Maintenance Lug Nut Torque RequirementsStart all wheel lug nuts by hand TLG-12SPX4 Generatorwiring Diagram Generator Wiring DiagramTLG-12SPX4 Enginewiring Diagram TLG-12SPX4 -TROUBLESHOOTING Engine Engine TroubleshootingTLG-12SPX4 -TROUBLESHOOTING Engine TLG-12SPX4 -TROUBLESHOOTING Generator Sample Parts List TLG 12SPX4 Explanation of Code in Remarks ColumnPart number on this Suggested Spare Parts list TLG 12SPX4 Suggested Spare PartsDescription TLG 12SPX4 Generator Assy D4110000203 0601820037S10VB60 0601822638TLG 12SPX4 Control Panel Assy DB0223001503 00218060300601800408 Frequency METER, 45~65 Hz 0601805745 060180028148 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 B0354400003 303214300444A 0207004000 0601815109TLG 12SPX4 Engine and Radiator Assy B0924200144 17472970111585332435 B030320200452 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 0016906025 01936008000314900350 0314900430TLG 12SPX4 Battery Assy 0165105524 87222510047552253004 7872251004TLG 12SPX4 Muffler Assy B0331000503 B03330023031526312371 D9304000004TLG 12SPX4 Fueltank Assy B0363000103 A9924800024E2924300214 E1924300184TLG 12SPX4 Enclosure Assy B0413001302 B0493000703B0414300103 B049700000462 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 0021806016 34A 00300060000845047204 35A 0845045004TLG 12SPX4 Rubber Seals Assy 0314900690 03149005600314900920 0229400590TLG 12SPX4 Name Plate Assy 7440611013 1742B6390671104 237768 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 B0560100004 B0560100604B0560100204 B0560100304Terms and Conditions of Sale Parts Freight PolicyTLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 HERE’S HOW to GET Help

TLG-12SPX4 specifications

The Multiquip TLG-12SPX4 is a premier choice in the realm of portable generators, designed to deliver reliable power for a variety of applications. As the demand for efficient and mobile power sources continues to rise, the TLG-12SPX4 stands out with a host of innovative features and advanced technologies that cater to both professional and recreational uses.

One of the main features of the TLG-12SPX4 is its robust power output. The generator is equipped with a powerful engine capable of producing up to 12,000 watts of peak power. This makes it suitable for construction sites, outdoor events, and emergency situations, where dependable electricity is crucial. The generator’s impressive output ensures that multiple tools and appliances can operate simultaneously without any drops in performance.

In terms of design, the Multiquip TLG-12SPX4 boasts a durable and heavy-duty frame that is built to withstand the rigors of job sites and harsh weather conditions. The unit is also equipped with a weather-resistant cover to protect its components from the elements, ensuring longevity and reliability. Its compact size and wheel kit allow for easy transport, making it a favored choice for contractors and outdoor enthusiasts alike.

The technology embedded in the TLG-12SPX4 enhances its user-friendliness and efficiency. It features a digital display that provides real-time information such as voltage output, power consumption, and runtime. This allows users to monitor their power usage closely. Additionally, the electric start system simplifies operation, eliminating the need for tedious manual starting procedures.

Safety is another paramount aspect of the TLG-12SPX4 design. The unit comes equipped with automatic low-oil shutdown technology, which protects the engine from damage by automatically shutting off when oil levels are critically low. Circuit breakers are also integrated to prevent overloads, ensuring safe operation for users.

In conclusion, the Multiquip TLG-12SPX4 is a powerful, durable, and user-friendly generator that exemplifies what modern portable power solutions should provide. With its impressive output, robust construction, advanced technologies, and thoughtful safety features, it stands ready to meet the diverse power needs of its users, whether on a job site or in a home emergency situation. Its combination of efficiency and reliability makes it a top choice among generators in its class.