Multiquip TLG-12SPX4 operation manual Battery Cable Installation, Alternator, Wiring

Page 28

Battery

This unit is of negative ground DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not properly maintained. Add only distilled water when replenishment is necessary.

DO NOT over fill. Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions. Always keep the terminals firmly tightened. Coating the terminals with an approved battery terminal treatment compound. Replace battery with only recommended type battery.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Before charging the battery with an external electric source, be sure to disconnect the battery cables.

Battery Cable Installation

ALWAYS be sure the battery cables (Figure 19) are properly connected to the battery terminals as shown below.The Red Cable is connected to the positive terminal of the battery, and the Black Cable is connected to the negative terminal of the battery.

CAUTION - BATTERY SERVICING SAFETY

ALWAYS disconnect the negative terminal FIRST and reconnect negative terminal LAST.

TLG-12SPX4 — SETUP

When connecting battery do the following:

1.NEVER connect the battery cables to the battery terminals when the ignition switch is in the ON position

2.Place a small amount of battery terminal treatment compound around both battery terminals.This will ensure a good connection and will help prevent corrosion around the battery terminals.

If the battery cable is connected

NOTE incorrectly, electrical damage to the generator will occur. Pay close attention to the polarity of the battery when connecting the battery.

CAUTION - BATTERY SERVICING SAFETY

Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.

Alternator

The polarity of the alternator is negative grounding type. When an inverted circuit connection takes place, the circuit will be in short circuit instantaneously resulting the alternator failure.

DO NOT put water directly on the alternator. Entry of water into the alternator can cause corrision and damage the alternator.

Wiring

Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.

Piping and Hose Connection

Inspect all piping, oil hose, and fuel hose connections for wear and tightness.Tighten all hose clamps and check hoses for leaks.

If any hose (fuel or oil) lines are defective replace them immediately.

Figure 19. Battery Connections

PAGE 28 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV. #1 (12/17/09)

Image 28
Contents Model TLG-12SPX4 Diesel engine exhaust and some TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 Table of Contents Parts Ordering Procedures Ordering parts has never been easierTLG-12SPX4 Specifications Dimensions Dimension ft. mmTLG-12SPX4 Safety Message Alert Symbols Hazard SymbolsTLG-12SPX4 Safety Message Alert Symbols General Safety TLG-12SPX4 Rules for Safe OperationInjury People Carbon monoxide gasTLG-12SPX4 Rules for Safe Operation Battery Safety TLG-12SPX4 Rules for Safe OperationDeath Towing and Transporting Safety Guidelines section in this manualTLG-12SPX4 Installation TLG-12SPX4 Installation Outdoor InstallationIndoor Installation MountingTLG-12SPX4 General Information TLG-12SPX4 Major Components TLG-12SPX4 Generator Control Panel TLG-12SPX4 Generator Control Panel TLG-12SPX4 Output Terminal Panel Familiarization Output Terminal Familiarization120VAC Gfci Receptacle TLG-12SPX4 Output Terminal Panel FamiliarizationL5-30RTwist Lock 120VAC Receptacle Option Connecting Loads TLG-12SPX4 Output Terminal Panel FamiliarizationSingle Phase Load TLG-12SPX4 Load APPLICATION/MAXIMUM AmperageGenerator Amperage Rated Voltage Maximum AmpsTLG-12SPX4 Setup Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure RefuelingCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Battery Cable InstallationWiring AlternatorBefore Starting Engines exhaust contains harmful emissionsDirect exhaust away from nearby personnel Close all engine enclosure doors FigureTLG-12SPX4 Generator START-UP Procedure Manual Emergency Shutdown Procedure Normal Shutdown ProcedurePlace both the main circuit breaker to the OFF position TLG-12SPX4 Maintenance Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterBrake Adjustment BrakesCheck the wheel and drum for free rotation Hydraulic Surge BrakesTLG-12SPX4 -TRAILER Maintenance Tires/Wheels/Lug NutsTireWear/Inflation SuspensionLug Nut Torque Requirements TLG-12SPX4 -TRAILER MaintenanceStart all wheel lug nuts by hand TLG-12SPX4 Generatorwiring Diagram Generator Wiring DiagramTLG-12SPX4 Enginewiring Diagram TLG-12SPX4 -TROUBLESHOOTING Engine Engine TroubleshootingTLG-12SPX4 -TROUBLESHOOTING Engine TLG-12SPX4 -TROUBLESHOOTING Generator Sample Parts List TLG 12SPX4 Explanation of Code in Remarks ColumnTLG 12SPX4 Suggested Spare Parts Part number on this Suggested Spare Parts listDescription TLG 12SPX4 Generator Assy D4110000203 0601820037S10VB60 0601822638TLG 12SPX4 Control Panel Assy DB0223001503 00218060300601800408 Frequency METER, 45~65 Hz 0601805745 060180028148 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 B0354400003 303214300444A 0207004000 0601815109TLG 12SPX4 Engine and Radiator Assy B0924200144 17472970111585332435 B030320200452 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 0016906025 01936008000314900350 0314900430TLG 12SPX4 Battery Assy 0165105524 87222510047552253004 7872251004TLG 12SPX4 Muffler Assy B0331000503 B03330023031526312371 D9304000004TLG 12SPX4 Fueltank Assy B0363000103 A9924800024E2924300214 E1924300184TLG 12SPX4 Enclosure Assy B0413001302 B0493000703B0414300103 B049700000462 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 0021806016 34A 00300060000845047204 35A 0845045004TLG 12SPX4 Rubber Seals Assy 0314900690 03149005600314900920 0229400590TLG 12SPX4 Name Plate Assy 7440611013 1742B6390671104 237768 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 B0560100004 B0560100604B0560100204 B0560100304Terms and Conditions of Sale Parts Freight PolicyTLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 HERE’S HOW to GET Help

TLG-12SPX4 specifications

The Multiquip TLG-12SPX4 is a premier choice in the realm of portable generators, designed to deliver reliable power for a variety of applications. As the demand for efficient and mobile power sources continues to rise, the TLG-12SPX4 stands out with a host of innovative features and advanced technologies that cater to both professional and recreational uses.

One of the main features of the TLG-12SPX4 is its robust power output. The generator is equipped with a powerful engine capable of producing up to 12,000 watts of peak power. This makes it suitable for construction sites, outdoor events, and emergency situations, where dependable electricity is crucial. The generator’s impressive output ensures that multiple tools and appliances can operate simultaneously without any drops in performance.

In terms of design, the Multiquip TLG-12SPX4 boasts a durable and heavy-duty frame that is built to withstand the rigors of job sites and harsh weather conditions. The unit is also equipped with a weather-resistant cover to protect its components from the elements, ensuring longevity and reliability. Its compact size and wheel kit allow for easy transport, making it a favored choice for contractors and outdoor enthusiasts alike.

The technology embedded in the TLG-12SPX4 enhances its user-friendliness and efficiency. It features a digital display that provides real-time information such as voltage output, power consumption, and runtime. This allows users to monitor their power usage closely. Additionally, the electric start system simplifies operation, eliminating the need for tedious manual starting procedures.

Safety is another paramount aspect of the TLG-12SPX4 design. The unit comes equipped with automatic low-oil shutdown technology, which protects the engine from damage by automatically shutting off when oil levels are critically low. Circuit breakers are also integrated to prevent overloads, ensuring safe operation for users.

In conclusion, the Multiquip TLG-12SPX4 is a powerful, durable, and user-friendly generator that exemplifies what modern portable power solutions should provide. With its impressive output, robust construction, advanced technologies, and thoughtful safety features, it stands ready to meet the diverse power needs of its users, whether on a job site or in a home emergency situation. Its combination of efficiency and reliability makes it a top choice among generators in its class.