Circuit Breakers

To protect the generator from an overload, a 3-pole, 50 amp, main circuit breaker has been provided. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level. and verify that the oil level is maintained between the two notches (Figure 12) on the dipstick. See Table 8 for proper selection of engine oil.

Figure 12. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the KUBOTA Engine Owner's Manual.Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

API Service Classification CC/SC

API Service Classification CC/SD

API Service Classification CC/SE

API Service Classification CC/SF

 

Table 8. Recommended Motor Oil

 

 

F

C

 

 

 

OIL: SAE

 

 

 

 

 

 

 

 

 

 

 

 

 

122

50

 

 

 

 

 

 

 

 

 

104

40

10W40

30

OIL

5W30

10W/40

15W30

10W30

10W

20W40

86

30

 

 

 

 

 

 

 

 

 

68

20

 

 

 

 

 

 

 

 

 

50

10

 

 

 

 

 

 

 

 

 

32

0

 

 

 

 

 

 

 

 

 

-14

-10

 

 

 

 

 

 

 

 

 

-4

-20

 

 

ARCTIC

 

 

 

 

 

 

-40

-40

 

 

 

 

 

 

 

 

-22

-30

 

 

 

 

 

 

 

 

 

TLG-12SPX4 — SETUP

Fuel Check

DANGER - EXPLOSION/FIRE HAZARDS

Fuel spillage on a hot engine can cause a fire or explosion. If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER smoke around or near the generator.

Refilling the Fuel System

CAUTION - REFUELINGTHE GENERATOR

ONLY properly trained personel who have read and understand this section should refill the fuel tank system.

This generator has an internal fuel tank located inside the trailer frame and may also be equipped with an optional environmental fuel tank (Figure 13). ALWAYS fill the fuel tanks with clean fresh #2 diesel fuel. DO NOT fill the fuel tanks beyond their capacities.

Pay attention to the fuel tank capacity when replenishing fuel.The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Figure 13. Internal Fuel Tank System

TLG-12SPX4— OPERATION AND PARTS MANUAL — REV. #1 (12/17/09) — PAGE 25

Image 25
Contents Model TLG-12SPX4 Diesel engine exhaust and some TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresTLG-12SPX4 Specifications Dimension ft. mm DimensionsHazard Symbols TLG-12SPX4 Safety Message Alert SymbolsTLG-12SPX4 Safety Message Alert Symbols TLG-12SPX4 Rules for Safe Operation General SafetyInjury People Carbon monoxide gasTLG-12SPX4 Rules for Safe Operation TLG-12SPX4 Rules for Safe Operation Battery SafetyDeath Guidelines section in this manual Towing and Transporting SafetyTLG-12SPX4 Installation Outdoor Installation TLG-12SPX4 InstallationIndoor Installation MountingTLG-12SPX4 General Information TLG-12SPX4 Major Components TLG-12SPX4 Generator Control Panel TLG-12SPX4 Generator Control Panel Output Terminal Familiarization TLG-12SPX4 Output Terminal Panel Familiarization120VAC Gfci Receptacle TLG-12SPX4 Output Terminal Panel FamiliarizationL5-30RTwist Lock 120VAC Receptacle Option TLG-12SPX4 Output Terminal Panel Familiarization Connecting LoadsTLG-12SPX4 Load APPLICATION/MAXIMUM Amperage Single Phase LoadGenerator Amperage Rated Voltage Maximum AmpsCircuit Breakers TLG-12SPX4 SetupLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorEngines exhaust contains harmful emissions Before StartingDirect exhaust away from nearby personnel Close all engine enclosure doors FigureTLG-12SPX4 Generator START-UP Procedure Manual Emergency Shutdown Procedure Normal Shutdown ProcedurePlace both the main circuit breaker to the OFF position TLG-12SPX4 Maintenance Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterBrakes Brake AdjustmentCheck the wheel and drum for free rotation Hydraulic Surge BrakesTires/Wheels/Lug Nuts TLG-12SPX4 -TRAILER MaintenanceTireWear/Inflation SuspensionLug Nut Torque Requirements TLG-12SPX4 -TRAILER MaintenanceStart all wheel lug nuts by hand Generator Wiring Diagram TLG-12SPX4 Generatorwiring DiagramTLG-12SPX4 Enginewiring Diagram Engine Troubleshooting TLG-12SPX4 -TROUBLESHOOTING EngineTLG-12SPX4 -TROUBLESHOOTING Engine TLG-12SPX4 -TROUBLESHOOTING Generator TLG 12SPX4 Explanation of Code in Remarks Column Sample Parts ListTLG 12SPX4 Suggested Spare Parts Part number on this Suggested Spare Parts listDescription TLG 12SPX4 Generator Assy 0601820037 D4110000203S10VB60 0601822638TLG 12SPX4 Control Panel Assy 0021806030 DB02230015030601800408 Frequency METER, 45~65 Hz 0601805745 060180028148 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 3032143004 B035440000344A 0207004000 0601815109TLG 12SPX4 Engine and Radiator Assy 1747297011 B09242001441585332435 B030320200452 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 0193600800 00169060250314900350 0314900430TLG 12SPX4 Battery Assy 8722251004 01651055247552253004 7872251004TLG 12SPX4 Muffler Assy B0333002303 B03310005031526312371 D9304000004TLG 12SPX4 Fueltank Assy A9924800024 B0363000103E2924300214 E1924300184TLG 12SPX4 Enclosure Assy B0493000703 B0413001302B0414300103 B049700000462 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 34A 0030006000 00218060160845047204 35A 0845045004TLG 12SPX4 Rubber Seals Assy 0314900560 03149006900314900920 0229400590TLG 12SPX4 Name Plate Assy 1742B 74406110136390671104 237768 TLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 B0560100604 B0560100004B0560100204 B0560100304Freight Policy Terms and Conditions of Sale PartsTLG-12SPX4- Operation and Parts Manual REV. #1 12/17/09 HERE’S HOW to GET Help

TLG-12SPX4 specifications

The Multiquip TLG-12SPX4 is a premier choice in the realm of portable generators, designed to deliver reliable power for a variety of applications. As the demand for efficient and mobile power sources continues to rise, the TLG-12SPX4 stands out with a host of innovative features and advanced technologies that cater to both professional and recreational uses.

One of the main features of the TLG-12SPX4 is its robust power output. The generator is equipped with a powerful engine capable of producing up to 12,000 watts of peak power. This makes it suitable for construction sites, outdoor events, and emergency situations, where dependable electricity is crucial. The generator’s impressive output ensures that multiple tools and appliances can operate simultaneously without any drops in performance.

In terms of design, the Multiquip TLG-12SPX4 boasts a durable and heavy-duty frame that is built to withstand the rigors of job sites and harsh weather conditions. The unit is also equipped with a weather-resistant cover to protect its components from the elements, ensuring longevity and reliability. Its compact size and wheel kit allow for easy transport, making it a favored choice for contractors and outdoor enthusiasts alike.

The technology embedded in the TLG-12SPX4 enhances its user-friendliness and efficiency. It features a digital display that provides real-time information such as voltage output, power consumption, and runtime. This allows users to monitor their power usage closely. Additionally, the electric start system simplifies operation, eliminating the need for tedious manual starting procedures.

Safety is another paramount aspect of the TLG-12SPX4 design. The unit comes equipped with automatic low-oil shutdown technology, which protects the engine from damage by automatically shutting off when oil levels are critically low. Circuit breakers are also integrated to prevent overloads, ensuring safe operation for users.

In conclusion, the Multiquip TLG-12SPX4 is a powerful, durable, and user-friendly generator that exemplifies what modern portable power solutions should provide. With its impressive output, robust construction, advanced technologies, and thoughtful safety features, it stands ready to meet the diverse power needs of its users, whether on a job site or in a home emergency situation. Its combination of efficiency and reliability makes it a top choice among generators in its class.