Multiquip DCA250SSIU manual Suggested Spare Parts, To 3 units

Page 55

SUGGESTED SPARE PARTS

DCA250SSI/DCA250SSIUWHISPERWATT GENERATORS

WITH ISUZU BH6UZ1X DIESEL ENGINE

1 to 3 units

QTY.

P/N

DESCRIPTION

 

1

M5311500003

HOSE, RADIATOR UPPER

1

M5311500103

HOSE, RADIATOR LOWER

1

0602011059

RADIATOR CAP

1

0605505025

FUEL CAP (DCA250SSI)

1

0605505070

FUEL CAP (DCA250SSIU)

3

1136714730

V-BELT SET

1

0602122272

OIL PRESSURE UNIT

1

0602123267

WATER TEMPERATURE UNIT

1

813NLU0000T

SWITCH, COOLANT LEVEL

6

0605505105

FILTER, FUEL TANK (DCA250SSI ONLY)

6

8980758551

FILTER, FUEL PRIMARY

6

8980088400

ELEMENT, MAIN FUEL FILTER

6

1132402322

FILTER, OIL CARTRIDGE, MAIN

3

0602046618

ELEMENT AIR CLEANER INNER

3

0602046617

ELEMENT AIR CLEANER OUTER

1

0601808803

CIRCUIT BREAKER 1P 20A

1

0601808804

CIRCUIT BREAKER 2P 50A

2

LY2DUS24VDC ....

RELAY

NOTICE

Part number on this Suggested Spare Parts list may supersede/replace the P/N shown in the text pages of this book.

DCA250SSI/DCA250SSIU GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (01/12/11) — PAGE 55

Image 55
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA250SSI Model DCA250SSIUProposition 65 Warning Nhtsa Reporting Safety DefectsDCA250SSI/DCA250SSIU 60HZ Generators Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationGenerator Safety General Safety Always know the location of the nearest Before servicing equipment Engine SafetyFrom fuel vapors or if fuel is spilled on a hot engine Fuel SafetyTowing Safety  Never use fuel as a cleaning agentDevice. All installations should be Electrical SafetyGrounding Safety Power Cord/Cable SafetyEnvironmental Safety Battery SafetyDCA250SSI/DCA250SSIU SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Item no Major ComponentsPilot Lamp Indicates the system is running Generator Control PanelOwing from the U,V, and W Output Terminal Lugs to the load Engine Operating Panel Air Filter Alarm When the air fi lterPage Output Terminal Familiarization Output Terminal Panel FamiliarizationTerminal legs O and Ground are considered bonded grounds 240V Twist-Lock Auxiliary Receptacles VAC Gfci ReceptaclesOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadLoad Application Generator Amperage Maximum Amps Generator OutputsGenerator Output Voltages Voltage Change-Over BoardAC Ammeter Gauge Reading HOW to Read the AC Ammeter and AC Voltage GaugesGenerator OUTPUTS/GAUGE Reading AC Voltmeter Gauge Reading1Ø-240V Uvwo Terminal Output Voltages Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-240V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages 3Ø-480V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages Fuel Check INSPECTION/SETUPCircuit Breakers Lubrication OILOnly use #2 diesel fuel when refueling Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAIR Cleaner FAN Belt Tension Coolant ANTIFREEZE/SUMMER COOLANT/ WaterAlternator BatteryBattery Cable Installation WiringBefore Starting Generator START-UP Procedure ManualStarting Manual Frequency Meter Starting Auto Mode Generator START-UP Procedure Auto ModeNever stop the engine suddenly except in an emergency Generator SHUT-DOWN ProceduresNormal Shutdown Procedure Emergency Shutdown ProcedureGeneral Inspection AIR Cleaner MaintenanceAir Cleaner with Dust Indicator Fuel Tank Inspection Fuel AdditionAIR Removal Flushing OUT Radiator and Replacing Coolant Radiator CleaningCheck OIL Level Replacing Oil FilterBattery Charger and Jacket Water Heater Power Connections Trailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesTire Wear/Inflation TIRES/WHEELS/LUG NutsSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramTroubleshooting Generator Adjust governor controller Troubleshooting Engine ControllerClean/repair radiator grill Adjust governor actuatorMethod of Operation Troubleshooting Diagnostic LampPage Explanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy 0601823282 C1110100802Includes Items W/# 0601842334Generator Assy 20A 952404470 C1154400103C1132300114 0340406040Engine Operating Panel Assy 0176060030 C3351100603M5351100103 0019206015Control BOX Assy M7030041000Q M52140000020601809667 011808015Control BOX Assy 8980137900 89721777807538070 8980056310Control BOX Assy 0601802149 06018022040027103020 0601806671Engine and Radiator Assy 1132402322 M59242000041136714730 8980088400Engine and Radiator Assy 0605515170 01999003500199900650 0193602300Output Terminal Assy M9220100914 C2231700403M5230700003 C0277500004Output Terminal Assy C2237101204 00300120000845043704 M9210000204Battery ASSY. DCA250SSI 7612252004 0165511551C9109100604 3972250004Battery ASSY. DCA250SSU 0602220921 0602220196M9310500404 M9104000004Muffler Assy C1334200304 M5331100002M5334000003 1141451920Fuel Tank Assy 0605505070 C1364002103M5364000002 0605505025Fuel Tank Assy 25C 021112140 001011008025A 0040010000 25B 031110160Enclosure Assy M1413400004 M5414000002M5414000102 C3414100104Enclosure Assy M5443600004 M5444200003M5444200103 8225147004Enclosure Assy 52A M5494400404 51B 0401450080M5454100003 52A C1494407404Rubber Seals Assy Rubber Seal Nameplate and Decals ASSY. DCA250SSI Control BOX Group Nameplate and Decals ASSY. -DCA250SSI Battery Group Nameplate and Decals ASSY. DCA250SSIU M5550000303 Nameplate and Decals ASSY. -DCA250SSIU Decal Document BOX Located Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help
Related manuals
Manual 4 pages 50.99 Kb

DCA250SSIU, DCA250SSI specifications

The Multiquip DCA250SSI and DCA250SSIU are powerful diesel generators designed to meet the demanding energy needs of various industries. These models are specifically engineered for reliability, efficiency, and performance, making them suitable for commercial applications, construction sites, and emergency backup power.

One of the standout features of both the DCA250SSI and DCA250SSIU is their impressive power output. Each model is capable of delivering 250 kVA, allowing users to run multiple equipment and tools simultaneously without worrying about power shortages. This makes them ideal for large-scale operations where consistent power is critical.

Both generators are equipped with a robust industrial-grade engine, ensuring long-lasting performance and durability. The DCA250SSI features a Kohler 4038T, whereas the DCA250SSIU includes a Yanmar engine. These engines are designed to operate efficiently under heavy loads while minimizing fuel consumption. The advanced design helps reduce emissions, making these models environmentally friendly.

The DCA250SSI and DCA250SSIU come with a sound-attenuated enclosure, which significantly reduces noise levels during operation. This design makes them suitable for use in urban settings or noise-sensitive environments, allowing businesses to comply with regulations without compromising on power supply.

Furthermore, both models integrate advanced technologies to enhance user experience. The digital controller allows for easy monitoring and control of the generator's performance, providing crucial information such as voltage, frequency, and engine parameters in real-time. This feature helps operators stay informed of the system's status and facilitates timely maintenance when needed.

Safety is another critical consideration in the design of these generators. The DCA250SSI and DCA250SSIU include a comprehensive range of safety features, such as low oil pressure shutdown, high-temperature shutdown, and overcurrent protection, ensuring reliable operation while safeguarding against potential hazards.

Versatility is key with these models. They can be configured for both single-phase and three-phase output, catering to diverse energy requirements across different applications. Additionally, their compact design makes them easy to transport and install, further enhancing their appeal for rental companies and on-the-go operations.

In conclusion, the Multiquip DCA250SSI and DCA250SSIU stand out in the generator market with their blend of power output, fuel efficiency, noise reduction, and advanced technologies. Their robust design and safety features make them a reliable choice for a wide array of industries, offering peace of mind and consistent energy wherever it's needed.