Multiquip dca25ssiu3 manual Enclosure Assy

Page 64

ENCLOSURE ASSY. (continued)

page 64 — DCA25SSIU3 (with MLT25 series) • operation and parts manual — rev. #1 (01/24/13)

Image 64
Contents Parts List NO. M1870301004C Model dca25ssiu3Proposition 65 warning Reporting Safety Defects AdministratorTable of Contents DCA25SSIU3 GeneratorChoose from three easy options SaFeTY MeSSageS Safety InformationSaFeTY SYMBoLS GeneraL SaFeTY GeneraTor SaFeTYRestricted. If the air fl ow is EngIne SaFeTYIf operating in speed ranges above the maximum allowable FUeL SaFeTY TowIng SaFeTY„ never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineELeCTrICaL SaFeTY Grounding SafetyPower Cord/Cable Safety DeathBaTTerY SaFeTY EnvIronMenTaL SaFeTY240/120 SpecificationsModel Isuzu BV 4LE2 Tier Dimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Major Components Item noGenerator Control Panel Generator Control PanelEngine Operating Panel Terminal legs O and Ground are considered bonded grounds Output Terminal FamiliarizationOutput Terminal Panel is provided with the following Removing the Plastic Face Plate Hard Wire Hookup Panel VAC Gfci ReceptaclesConnecting Loads Over Current RelaySingle Phase Load Three Phase LoadLoad Application Type of LoadVoltage Selector Switch Voltage Selector Switch Locking ButtonGenerator Output Voltages Generator AmperageHow to Read the ac ammeter and ac voltage gauges Generator OUTPUTS/gauge readingAC Voltmeter Gauge Reading AC Ammeter Gauge Reading3Ø-240/139 Uvwo Terminal Output Voltages Uvwo Terminal Output Voltages3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesInspection/SETUP Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCoolant Antifreeze/Summer Coolant/ Water Remove fuel cap from filler neck and fill tank FigureCleaning the Radiator Air Cleaner Fan Belt TensionBattery Operation in Freezing WeatherBattery Cable Installation WiringWhen connecting battery do the following AlternatorBefore Starting StartingStarting Manual Engine’s exhaust contains harmful emissionsIgnition Switch Start Position Emergency Shutdown Procedure Light tower operation Normal Shutdown ProcedureAutomatic Shut-down System General Inspection Air Cleaner MaintenanceAir Cleaner with Dust Indicator Cleaning Inside the Fuel Tank Fuel AdditionRemoving Water from the Fuel Tank Fuel Tank InspectionRadiator Cleaning Check Oil LevelReplacing Oil Filter Flushing Out Radiator and Replacing CoolantGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Symptom Possible Problem SolutionPage Explanation of Code in Remarks Column To 3 units Suggested Spare PartsQty Description Generator Assy B1110200602 79610250040601822630 8001070003Control box Assy M1213001102 06018704300021004075 0601842384Control box Assy 0601807641 0601808985 AC AMMETER, 0~50A/100A5A 06018010400601806859 0601801041Engine and Radiator Assy M1923200104 89726064902944566410 M1303200304Engine and Radiator Assy M9200200004 01500000180016906020 0199900600Output Terminal Assy M1230700003 M9220000004M9220000104 0039308000Battery Assy 0602220185 B9310500014M9103000304 0602220920Muffler Assy M1330100803 M13330028038970420280 M1333200014Fuel Filter Assy 8943672922 14A 8980374810M1366700104 8970398340Enclosure Assy M1413003302 M1413400004M1423002302 M1493104903Enclosure Assy Part Name QTY Rubber Seals Assy REMArks Nameplate and Decals Assy M1550000104 M1550000204M1550003312 M1550003412Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

dca25ssiu3 specifications

The Multiquip DCA25SSIU3 is a powerful and reliable generator that exemplifies performance and efficiency in portable power solutions. As part of Multiquip’s DCA series, this generator is designed with a focus on providing optimal power for construction sites, events, emergency backup, and various industrial applications.

One of the key features of the DCA25SSIU3 is its robust 25 kVA output, which is capable of handling significant loads with ease. This makes it suitable for powering multiple tools and equipment simultaneously, ensuring that operators can complete their tasks without interruption. The generator is equipped with a durable and quiet-running engine, which contributes to its reputation for reliability and ease of use.

In terms of technological advancements, the DCA25SSIU3 incorporates advanced inverter technology. This feature ensures that the output power is stable and clean, making it ideal for sensitive electronic equipment. This technology not only enhances performance but also increases fuel efficiency, allowing for longer operational periods between refueling.

Another notable characteristic of the DCA25SSIU3 is its compact design, coupled with a user-friendly control panel. The generator is designed to be portable, with integrated lifting points that make it easy to transport across various job sites. The control panel features clear indicators for easy monitoring of power output, fuel level, and operational status, empowering users to operate the generator with confidence.

Moreover, the DCA25SSIU3 is built with durability in mind. It features a rugged enclosure that protects vital components from the elements, including rain, dust, and debris. This design ensures that the generator can withstand tough job site conditions while providing reliable power.

In terms of safety, the DCA25SSIU3 is engineered with multiple protective features, including low oil shutdown and overload protection, which helps to prevent damage to the generator and connected equipment.

Overall, the Multiquip DCA25SSIU3 stands out as a robust, efficient, and reliable choice for those seeking a dependable portable power solution that meets the demands of various environments and applications.