Multiquip operation manual DCA-400SPK TRAILER-SAFETY Guidelines, Explanation of Chart

Page 11

DCA-400SPKTRAILER-SAFETY GUIDELINES

CAUTION:

ALWAYS make sure the trailer is in good operating condition. Check the tires for proper inflation and wear. Also check the wheel lug nuts for proper tightness.

Explanation of Chart:

This section is intended to provide the user with trailer ser- vice and maintenance information. The service and mainte- nance guidelines referenced in this section apply a wide range of trailers. Remember periodic inspection of the trailer will ensure safe towing of the equipment and will prevent dam- age to the equipment and personal injury.

It is the purpose of this section to cover the major mainte- nance components of the trailer. The following trailer com- ponents will be discussed in this section:

„Brakes

„Tires

„Lug Nut Torquing

„Suspension

„Electrical

„Brake Troubleshooting Tables

Use the following definitions with reading Table 1.

1.Fuel Cell - Provides an adequate amount of fuel for the equipment in use. Fuel cells must be empty when trans- porting equipment.

2.Braking System - System employed in stopping the trailer. Typical braking systems are electric, surge, hy- draulic, hydraulic-surge and air.

3.GVWR- Gross Vehicle Weight Rating (GVWR), is the maximum number of pounds the trailer can carry, in- cluding the fuel cell (empty).

4.Frame Length - This measurement is from the ball hitch to the rear bumper (reflector).

5.Frame Width - This measurement is from fender to fender.

6.Jack Stand - Trailer support device with maximum pound requirement from the tongue of the trailer.

7.Coupler - Type of hitch used on the trailer for towing.

8.Tire Size - Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters (175,185,205, etc.). The tire diameter must match the diameter of the tire rim.

9.Tire Ply - The tire ply (layers) number is rated in letters; 2-ply,4-ply,6-ply, etc.

10.Wheel Hub - The wheel hub is connected to the

trailer’s axle.

11.Tire Rim - Tires mounted on a tire rim. The tire rim must match the size of the tire.

12.Lug Nuts - Used to secure the wheel to the wheel hub. Always use a torque wrench to tighten down the lug nuts. See Table 4 and Figure 5 or lug nut tightening and sequence.

13.Axle - Indicates the maximum weight the axle can sup- port in pounds, and the diameter of the axle expressed in inches (see Table 3). Please not that some trailers have a double axle. This will be shown as 2-6000 lbs., meaning two axles with a total weight capacity of 6000 pounds.

14.Suspension - Protects the trailer chassis from shocks transmitted through the wheels. Types of suspension used are leaf, Q-flex, and air ride.

15.Electrical - Electrical connectors (looms) are provided with the trailer so the brake lights and turn signals can be connected to the towing vehicle.

16.Application - Indicates which units can be employed on a particular trailer.

DCA-400SPK — PARTS AND OPERATION MANUAL — REV. #0 (06/19/01) — PAGE 11

Image 11
Contents MQ Power DCA-400SPK Whisperwatttm Generator Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures Earn Extra Discounts when You order by FAXRules for Safe Operation High Temperatures AllowRadiator Rules for Safe OperationLoading and Unloading Crane BatteryEmergencies Maintenance SafetyTransporting DCA-400SPK -TOWING Towing Safety PrecautionsExplanation of Chart DCA-400SPK TRAILER-SAFETY GuidelinesTRLR-100XF DCA-400SPK -TRAILER-SPECIFICATIONSElectrical DCA-400SPK -TRAILER-SPECIFICATIONSElectric Brakes Electric Brake AdjustmentBrakes Hydraulic/Air/Surge Brakes DCA-400SPK -TRAILER Safety GuidelinesSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Lug Nut Torque Requirements Torque Ft.-LbsDCA-400SPK -TRAILER-WIRING Diagram Electric Brake Troubleshooting DCA-400SPK -TRAILER-BRAKETROUBLESHOOTINGDCA-400SPK -TRAILER-BRAKETROUBLESHOOTING Machine Safety Decals DCA-400SPK Operation and Safety DecalsDCA-400SPK Operation and Safety Decals DCA-400SPK Specifications DCA-400SPK General Information JacketWater Heater Optional Battery ChargerEngine Mechanical Governor SystemMajor Components DCA-400SPK Major ComponentsPage Dimensions DCA-400SPK Dimensions TOP and SideDCA-400SPK Dimensions Front and Rear Control Panel DCA-400SPK Control PanelEngine Control Module Voltage Regulator Control AllowsMpec Microprocessor DCA-400SPK Engine Operating Panel DCA-400SPK Engine Operating Panel DCA-400SPK Outputterminal Panel Overview DCA-400SPK Outputterminal Panel Overview Maximum Amps Output Terminal Panel Available VoltagesOver Current Relay DCA-400SPK Outputterminal Panel Overview How to read the output terminal gaugesVoltage Change-over Board Single Phase, 240 VoltPhase, 240 Volt Single Phase, 139 VoltSingle Phase, 277 Volt Single Phase, 480 VoltPhase, 480 Volt Mounting DCA-400SPK InstallationOutdoor Installation Typical Generator Grounding Application DCA-400SPK InstallationExtension Cable DCA-400SPK PRE-SETUPGeneral Inspection Prior to Operation Type Oil Lubrication OilFuel CoolantFan Belt Tension Cleaning the RadiatorAir Cleaner Operation in Freezing WeatherPiping and Hose Connection Battery Cable InstallationWiring Three Phase Load Single Phase LoadBefore Starting Generator and Control Panel Before Starting EngineSet the battery ON/OFF switch to the on position Off/Manual/Auto Switch Manual DCA-400SPK Generator START-UP Procedure ManualMain and Gfci Circuit Breakers DCA-400SPK Generator START-UP Procedure Auto Emergency Stop DCA-400SPK Generator Shutdown ProcedureEngine Shutdown Page DCA-400SPK Maintenance Replacing fuel filter Check Electric Heater If equippedChanging Oil Generator Storage Cleaning breather elementGreasing Inspection / Maintenance DCA-400SPK Generator Wiring Diagram Page DCA-400SPK Engine Wiring Diagram DCA-400SPK Engine Wiring Diagram Mpec DCA-400SPK -TROUBLESHOOTING Engine DCA-400SPK -TROUBLESHOOTING Engine Generator Troubleshooting DCA-400SPK -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-400SPK -TROUBLESHOOTING MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-400SPK Suggested Spare PartsDCA-400SPK Generator Assy Part Name QTY Remarks DCA-400SPK Generator Assy Part Name QTY DCA-400SPK Control BOX Assy Part Name DCA-400SPK Control BOX Assy SL2AS DCA-400SPK Engine & Radiator Assy BRACKET, Radiator DCA-400SPK Engine & Radiator Assy CAP, Reserve Tank DCA-400SSKENGINE Operating Panel Assy DCA-400SPK Engine Operating Panel Assy DCA-400SSKENGINE Operating Panel Assy Terminal Plate DCA-400SPK Battery Assy Battery DCA-400SPK Muffler Assy Muffler DCA-400SPK Fuel Tank Assy Fuel Tank DCA-400SPK Enclosure Assy Base DCA-400SPK Enclosure Assy COVER, Rear Frame DCA-400SPK Enclosure Assy Filler Cover DCA-400SPK Enclosure Assy Duct DCA-400SPK Rubber Seal Assy Rubber Seal Assy DCA-400SPK OIL Piping Assy Pump DCA-400SPK Name Plate and Decals Control BOX Group Bonnet Group Battery Group Engine and Radiator Group Engine & Radiator Group Effective July 1 Page Mail mq@multiquip.com WWW multiquip.com

DCA-400SPK specifications

The Multiquip DCA-400SPK is a powerful and versatile diesel generator designed to meet the demands of both commercial and industrial applications. Known for its robust performance and reliable operation, this generator is engineered to provide consistent power in various environments, making it a go-to solution for contractors, events, and emergency backup needs.

One of the DCA-400SPK's standout features is its Cummins QSB6.7 engine, which provides 400 kVA (kilovolt-amps) of output. This engine is renowned for its fuel efficiency and durability, ensuring that users get the most out of their investment without frequent refueling. The generator is also equipped with a two-pole alternator that contributes to its ability to handle heavy loads without compromising performance.

Another notable characteristic of the DCA-400SPK is its advanced control panel. The generator comes with a fully digital control system that offers real-time monitoring and control of the generator’s functions. This includes features such as automatic voltage regulation (AVR), which ensures stable output voltage, and can be vital for protecting sensitive electronic equipment from power fluctuations.

In terms of sound attenuation, the DCA-400SPK is designed with a sound-attenuated canopy that significantly reduces noise levels during operation. This makes it suitable for use in residential areas or other noise-sensitive locations, allowing for operation without disturbing the surrounding community.

For ease of transport, the generator includes a sturdy frame and is equipped with forklift pockets and lifting hooks. This enhances its portability, making it easier to move from one job site to another. Additionally, the unit offers comprehensive connectivity options, allowing it to interface with remote monitoring systems, which can be essential for maintenance and operational oversight.

The Multiquip DCA-400SPK also features an environmentally friendly design, with a low oil shutdown feature and a robust fuel containment system to prevent spills. This not only ensures compliance with environmental regulations but also enhances the safety of operation.

Overall, the DCA-400SPK stands out as a reliable, efficient, and user-friendly generator that meets the stringent demands of the modern world, making it a preferred choice among professionals in various industries.