Multiquip DCA-400SPK operation manual Lubrication Oil, Fuel, Coolant, Type Oil

Page 43

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but do not overfill. Make sure the generator is level. With the dipstick inserted all the way, but without being screw into the filler hole, verify that the oil level is maintained between the two notches (Figure 28) on the dipstick. See Table 9 for proper selection of engine oil.

DCA-400SPKPRE-SETUP

Fuel

Fill the fuel tank with clean and fresh diesel fuel. DO NOT fill the tank beyond capacity.

Pay attention to the fuel tank capacity when replenishing fuel. Refer to the fuel tank capacity listed on page 23, Specification Table 7.

The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Figure 28. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean and viscous. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the Komatsu Engine Owner's Manual.

CAUTION:

Never fill the fuel tank while the engine is running or in the dark. Diesel spillage on a hot engine can cause a fire or explosion. If diesel spillage occurs, wipe up the spilled diesel completely to prevent fire hazards.

Coolant

Use only drinkable tap water. If hard water or water with many impurities is used, the inside of the engine and radiator may become coated with deposits and cooling efficiency will be reduced.

An anticorrosion additive added to the water will help prevent deposits and corrosion in the cooling system. See the engine manual for further details.

Table 11. Recommended Motor Oil

Temperature

Type Oil

Range

 

 

 

104° F ~ 23° F

SAE 30

(40° C ~ -5°C)

 

 

 

23° F ~ 5° F

SAE 20 or SAE 10W-30

(-5° C ~ -15°C)

 

Below 5° C (-15°)

SAE 10W or SAE 10W-30

DCA-400SPK — PARTS AND OPERATION MANUAL — REV. #0 (06/19/01) — PAGE 43

Image 43
Contents MQ Power DCA-400SPK Whisperwatttm Generator Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures Earn Extra Discounts when You order by FAXRules for Safe Operation High Temperatures AllowRadiator Rules for Safe OperationLoading and Unloading Crane BatteryTransporting Maintenance SafetyEmergencies DCA-400SPK -TOWING Towing Safety PrecautionsExplanation of Chart DCA-400SPK TRAILER-SAFETY GuidelinesTRLR-100XF DCA-400SPK -TRAILER-SPECIFICATIONSElectrical DCA-400SPK -TRAILER-SPECIFICATIONSBrakes Electric Brake AdjustmentElectric Brakes Hydraulic/Air/Surge Brakes DCA-400SPK -TRAILER Safety GuidelinesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements Torque Ft.-LbsDCA-400SPK -TRAILER-WIRING Diagram Electric Brake Troubleshooting DCA-400SPK -TRAILER-BRAKETROUBLESHOOTINGDCA-400SPK -TRAILER-BRAKETROUBLESHOOTING Machine Safety Decals DCA-400SPK Operation and Safety DecalsDCA-400SPK Operation and Safety Decals DCA-400SPK Specifications DCA-400SPK General Information JacketWater Heater Optional Battery ChargerEngine Mechanical Governor SystemMajor Components DCA-400SPK Major ComponentsPage Dimensions DCA-400SPK Dimensions TOP and SideDCA-400SPK Dimensions Front and Rear Control Panel DCA-400SPK Control PanelMpec Microprocessor Voltage Regulator Control AllowsEngine Control Module DCA-400SPK Engine Operating Panel DCA-400SPK Engine Operating Panel DCA-400SPK Outputterminal Panel Overview DCA-400SPK Outputterminal Panel Overview Over Current Relay Output Terminal Panel Available VoltagesMaximum Amps DCA-400SPK Outputterminal Panel Overview How to read the output terminal gaugesVoltage Change-over Board Single Phase, 240 VoltPhase, 240 Volt Single Phase, 139 VoltPhase, 480 Volt Single Phase, 480 VoltSingle Phase, 277 Volt Outdoor Installation DCA-400SPK InstallationMounting Typical Generator Grounding Application DCA-400SPK InstallationGeneral Inspection Prior to Operation DCA-400SPK PRE-SETUPExtension Cable Type Oil Lubrication OilFuel CoolantFan Belt Tension Cleaning the RadiatorAir Cleaner Operation in Freezing WeatherWiring Battery Cable InstallationPiping and Hose Connection Three Phase Load Single Phase LoadBefore Starting Generator and Control Panel Before Starting EngineSet the battery ON/OFF switch to the on position Off/Manual/Auto Switch Manual DCA-400SPK Generator START-UP Procedure ManualMain and Gfci Circuit Breakers DCA-400SPK Generator START-UP Procedure Auto Engine Shutdown DCA-400SPK Generator Shutdown ProcedureEmergency Stop Page DCA-400SPK Maintenance Changing Oil Check Electric Heater If equippedReplacing fuel filter Greasing Cleaning breather elementGenerator Storage Inspection / Maintenance DCA-400SPK Generator Wiring Diagram Page DCA-400SPK Engine Wiring Diagram DCA-400SPK Engine Wiring Diagram Mpec DCA-400SPK -TROUBLESHOOTING Engine DCA-400SPK -TROUBLESHOOTING Engine Generator Troubleshooting DCA-400SPK -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-400SPK -TROUBLESHOOTING MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-400SPK Suggested Spare PartsDCA-400SPK Generator Assy Part Name QTY Remarks DCA-400SPK Generator Assy Part Name QTY DCA-400SPK Control BOX Assy Part Name DCA-400SPK Control BOX Assy SL2AS DCA-400SPK Engine & Radiator Assy BRACKET, Radiator DCA-400SPK Engine & Radiator Assy CAP, Reserve Tank DCA-400SSKENGINE Operating Panel Assy DCA-400SPK Engine Operating Panel Assy DCA-400SSKENGINE Operating Panel Assy Terminal Plate DCA-400SPK Battery Assy Battery DCA-400SPK Muffler Assy Muffler DCA-400SPK Fuel Tank Assy Fuel Tank DCA-400SPK Enclosure Assy Base DCA-400SPK Enclosure Assy COVER, Rear Frame DCA-400SPK Enclosure Assy Filler Cover DCA-400SPK Enclosure Assy Duct DCA-400SPK Rubber Seal Assy Rubber Seal Assy DCA-400SPK OIL Piping Assy Pump DCA-400SPK Name Plate and Decals Control BOX Group Bonnet Group Battery Group Engine and Radiator Group Engine & Radiator Group Effective July 1 Page Mail mq@multiquip.com WWW multiquip.com

DCA-400SPK specifications

The Multiquip DCA-400SPK is a powerful and versatile diesel generator designed to meet the demands of both commercial and industrial applications. Known for its robust performance and reliable operation, this generator is engineered to provide consistent power in various environments, making it a go-to solution for contractors, events, and emergency backup needs.

One of the DCA-400SPK's standout features is its Cummins QSB6.7 engine, which provides 400 kVA (kilovolt-amps) of output. This engine is renowned for its fuel efficiency and durability, ensuring that users get the most out of their investment without frequent refueling. The generator is also equipped with a two-pole alternator that contributes to its ability to handle heavy loads without compromising performance.

Another notable characteristic of the DCA-400SPK is its advanced control panel. The generator comes with a fully digital control system that offers real-time monitoring and control of the generator’s functions. This includes features such as automatic voltage regulation (AVR), which ensures stable output voltage, and can be vital for protecting sensitive electronic equipment from power fluctuations.

In terms of sound attenuation, the DCA-400SPK is designed with a sound-attenuated canopy that significantly reduces noise levels during operation. This makes it suitable for use in residential areas or other noise-sensitive locations, allowing for operation without disturbing the surrounding community.

For ease of transport, the generator includes a sturdy frame and is equipped with forklift pockets and lifting hooks. This enhances its portability, making it easier to move from one job site to another. Additionally, the unit offers comprehensive connectivity options, allowing it to interface with remote monitoring systems, which can be essential for maintenance and operational oversight.

The Multiquip DCA-400SPK also features an environmentally friendly design, with a low oil shutdown feature and a robust fuel containment system to prevent spills. This not only ensures compliance with environmental regulations but also enhances the safety of operation.