DCA-20SPX — GENERATOR CONTROL PANEL

4

INCREASEDECREASE

HZ

1

5

V

2

U W

OFF

A

6

V

3

Figure 6. Generator Control Panel

The definitions below describe the controls and functions of the DCA-20SPX Generator Control Panel (Figure 6).

1.Frequency Meter – Indicates the output frequency in hertz (Hz). Normally 60 Hz.

2.AC Ammeter – Indicates the amount of current the load is drawing from the generator per leg selected by the ammeter phase-selector switch.

3.AC Voltmeter – Indicates the output voltage present at the U,O, and V Output Terminal Lugs.

4.Voltage Regulator Control – Allows ±15% manual adjustment of the generator’s output voltage.

5.Ammeter Change-Over Switch – This switch allows the AC ammeter to indicate the current flowing to the load connected to any phase of the output terminals, or to be switched off. This switch does not effect the generator output in any fashion, it is for current reading only.

6.Main Circuit Breaker – This three-pole, 90A main breaker is provided to protect the the U,O, andV Output Terminal Lugs from overload.

Located behind the generator control panel is the Generator Control Box. This box contains some of the necessary electronic components required to make the generator function.

The Control Box is equipped with the following major components:

Over-Current Relay

Voltage Rectifer (AVR)

Starter Relay

Current Transformer

Voltage Selector Switch

Single Phase Circuit Breaker

Remember the overcurrent

NOTErelay monitors the current flowing from the U,O and V Output Terminal Lugs to the load.

In the event of a short circuit or over current condition, it will automatically trip the 90 amp main breaker.

To restore power to the Output Terminal Panel, press the reset button on the overcurrent relay and place the main circuit breaker in the closed position (ON).

DCA-20SPX— OPERATION AND PARTS MANUAL — REV. #2 (04/14/10) — PAGE 23

Image 23
Contents Model DCA-20SPX Parts List NO. B1871302604Diesel engine exhaust and some Proposition 65WARNINGDCA-20SPX- Operation and Parts Manual REV. #2 04/14/10 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresDCA-20SPX Specifications Dimensions DCA-20SPX Dimensions TOP, Side and FrontHazard Symbols DCA-20SPX Safety Message Alert SymbolsDCA-20SPX Safety Message Alert Symbols Carbon monoxide gas General SafetyDCA-20SPX Rules for Safe Operation Injury PeopleDCA-20SPX Rules for Safe Operation Maintenance SafetyDCA-20SPX Rules for Safe Operation Battery SafetyDeath Guidelines section in this manual Towing and Transporting SafetyDCA-20SPX- Operation and Parts Manual REV. #2 04/14/10 Generator Decals DCA-20SPX Generator DecalsGenerator Decals Cont inued DCA-20SPX Generator DecalsTypical Generator Grounding Application DCA-20SPX InstallationMounting Outdoor InstallationIndoor Installation When connecting the generatorOutput Terminal Panel GeneratorEngine Operating Panel Generator Control PanelMajor Components DCA-20SPX Major Components22 DCA-20SPX- Operation and Parts Manual REV. #2 04/14/10 DCA-20SPX Generator Control Panel DCA-20SPX Engine Operating Panel Auto On/Off Engine Controller Mpec DCA-20SPX Engine Operating PanelOutput Terminal Familiarization DCA-20SPX Output Terminal Panel Familiarization120VAC Gfci Receptacles DCA-20SPX Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsGenerator Amperage Single Phase LoadDCA-20SPX Load APPLICATION/MAXIMUM Amperage Motors and motor-drivenDCA-20SPX Gauge READING/TERMINAL Panel Connections Fuel Check DCA-20SPX SetupCircuit Breakers Lubrication OilRefueling Refueling ProcedureOperation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/WaterAlternator BatteryBattery Cable Installation WiringDirect exhaust away from nearby personnel DCA-20SPX Generator START-UP Procedure ManualBefore Starting Engines exhaust contains harmful emissionsOn position Figure VoltmeterPlace the Mpec Control Switch in the Auto position Starting Auto ModeEmergency Shutdown Procedure DCA-20SPX Generator SHUT-DOWN ProceduresNormal Shutdown Procedure DCA-20SPX Maintenance Replacing Oil Filter Cleaning the Fuel StrainerAir Removal Check Oil LevelTo ensure adequate starting Battery Charger JacketWater Heater Power ConnectionsTrailer Maintenance DCA-20SPX -TRAILER MaintenanceCheck the wheel and drum for free rotation DCA-20SPX -TRAILER MaintenanceBrake Adjustment BrakesSuspension Tires/Wheels/Lug NutsTireWear/Inflation Start all wheel lug nuts by hand Lug Nut Torque RequirementsDCA-20SPX -TRAILERWIRING Diagram Generator Wiring Diagram DCA-20SPX Generatorwiring DiagramDCA-20SPX Enginewiring Diagram Engine Troubleshooting DCA-20SPX -TROUBLESHOOTING EngineDCA-20SPX -TROUBLESHOOTING Engine Generator Troubleshooting DCA-20SPX -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-20SPX -TROUBLESHOOTING Engine ControllerDCA-20SPX- Operation and Parts Manual REV. #2 04/14/10 QTY. Column DCA-20SPX Explanation of Code in Remarks ColumnDescription Part number on this Suggested Spare Parts listDCA-20SPX Suggested Spare Parts DCA-20SPX Generator Assy 8001070003 B01101001027961025004 0601822630DCA-20SPX- Engine Operating Panel Assy 0602121080 06021200950602122093 0602123090Control BOX ASSY. S/N 7800001~7800129 DCA-20SPX- Control BOX Assy0601842384 B12140031020601870433 0021004075DCA-20SPX- Engine and Radiator Assy M1303200304 M19232000448972249990 894456741164 DCA-20SPX- Operation and Parts Manual REV. #2 04/14/10 0016906020 1622014103M9200200004 0150000018Output Terminal Assy DCA-20SPX- Outputterminal Assy0039308000 B12317003030840312704 0801830604DCA-20SPX- Battery Assy 0602220920 0602220185B9310500004 M9103000304DCA-20SPX- Muffler Assy B1333200804 B1330101403M1333201703 0602320100DCA-20SPX- Fueltank Assy 0805003404 M13630002120605505070 M1363200004Enclosure Assy DCA-20SPX- Enclosure AssyM1493104903 M1413002802M1413400004 M1423001802Enclosure ASSY. DCA-20SPX- Enclosure ASSY.34A M1493405704 M1453003080333A M1493405604 M1453003903DCA-20SPX- Rubber Seals Assy B1491300004 02289011700228900695 0228900725DCA-20SPX- Nameplate and Decals Assy B15100330 B1551003203B15100320 B155100330382 DCA-20SPX- Operation and Parts Manual REV. #2 04/14/10 DCA-20SPX- Operation and Parts Manual REV. #2 04/14/10 HERE’S HOW to GET Help

DCA-20SPX specifications

The Multiquip DCA-20SPX is a versatile and robust portable generator designed to meet the power demands of various applications, from construction sites to outdoor events. Boasting a compact and lightweight design, this generator is engineered to offer exceptional performance in a multitude of environments.

One of the standout features of the DCA-20SPX is its reliable power output. Powered by a reliable diesel engine, the generator delivers a continuous output of 20 kVA, making it suitable for both small and medium-sized operations. This generator is particularly favored for its efficient fuel consumption, allowing users to operate for extended periods without frequent refueling.

Another key characteristic of the DCA-20SPX is its advanced inverter technology, ensuring stable and clean power suitable for sensitive electronic equipment. This technology effectively minimizes harmonic distortion, providing an output that is safe for powering computers, medical devices, and other electronics requiring a stable power supply.

The generator’s user-friendly control panel is designed for ease of operation. It features clear displays and intuitive controls, allowing operators to monitor key performance indicators like voltage, frequency, and hour meter with ease. Additionally, the panel includes multiple outlet options, accommodating various plug types, which enhances its versatility on job sites.

Durability is a hallmark of the Multiquip DCA-20SPX’s design. The generator is built with a sturdy steel frame and finished with weather-resistant coatings, enabling it to withstand the rigors of outdoor usage in challenging conditions. Its integrated handling features, such as fork pockets and lifting eyes, also facilitate easy transport and setup.

For user safety, the DCA-20SPX is equipped with essential protection features. It includes low oil shutdown, overload protection, and thermal shutdown, which collectively safeguard the generator from potential damage, ensuring long operational life and reliability.

Overall, the Multiquip DCA-20SPX excels in providing reliable energy solutions for various applications, adorned with advanced technologies, user-friendly features, and a robust build. Whether for construction, emergency power supply, or remote events, it stands as a trusted ally for those who require efficient and dependable power on demand.