24CHOOSING A DISCRIMINATION PATTERN
EDITING DISCRIMINATION PATTERNS 25
Pattern Discrimination
In Coin & Treasure
Mode use PATTERNS
to toggle between Pattern 1, Pattern 2 and Pattern 3.
All Metal Shortcut
The
In Coin & Treasure Mode,
press ALL METAL to toggle
between the selected
Pattern and All Metal.
The Preset Discrimination Patterns may be edited to create custom patterns.
Method 1 - to reject a specific Target ID using an actual target
When detecting a target, a discrimination segment will flash, indicating its position on the discrimination scale and the target’s ID number will appear on the LCD.
Press ACCEPT REJECT to reject that Target ID.
The discrimination segment and icon will appear to indicate that the detected ID is now rejected.
Check that the Target ID has been rejected by detecting again. There should be no audio response (blanking) from that target (Detector Audio, pg. 17).
Method 2 - to reject a specific Target ID using + –
Iron Mask
Discrimination | In Prospecting Mode, | |
press ALL METAL to | ||
In Prospecting Mode use | ||
toggle between Iron | ||
+ and – to adjust the | Mask and All Metal. | |
Iron Mask Discrimination |
| |
scale. |
|
Use + and – to scroll through and select the ID you want to modify. The flashing segment and the Target ID numbers will indicate the selected ID.
Press ACCEPT REJECT to either accept or reject that ID. The discriminated segment and the icon will appear if rejected. The segment and the icon will disappear if accepted.
When the Iron Mask Level is set to 0, |
|
the detector behaves the same as in |
|
All Metal Pattern. | ACCEPT REJECT toggles between |
The All Metal Pattern | |
cannot be edited. | accepting and rejecting targets. |