Kohler 12RES, 8.5RES manual Table of Contents

Page 3

Table of Contents

Product Identification Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inside front cover

Safety Precautions and Instructions

I

Introduction

. . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

i

Service Assistance . .

. . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ii

Section 1 Features . .

. . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1.1

Specifications

1

1.2

Generator

1

1.3

Engine .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1.4

Advanced Digital Control

1

1.5

Generator Set Components

2

Section 2 Operation .

. . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

2.1

Prestart Checklist

3

2.2

Exercising Generator Set

3

2.3

Generator Set Operation

3

 

2.3.1

Controls and Indicators

4

 

2.3.2

Starting Generator Set

4

 

2.3.3

Stopping Generator Set

4

2.4

Fault Shutdowns

5

 

2.4.1

Resetting Controller after a Fault Shutdown

6

2.5

Continuous Power Mode

6

2.6

Battery Charger

7

 

2.6.1

Battery Charger Operation

7

Section 3 Scheduled Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3.1 Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3.2 Service Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

3.3 Lubrication System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.3.1 Low Oil Pressure Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.3.2 Oil Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.3.3 Engine Oil Recommendation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.3.4 Oil Change Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.4 Spark Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3.5 Air Cleaner Element and Precleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3.5.1 Precleaner Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3.5.2 Paper Element Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3.6 Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

3.7 Exhaust System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

3.8 Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

3.9 Battery Charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3.10 Circuit Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3.10.1 Line Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3.10.2 Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3.11 Storage Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3.11.1 Lubricating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3.11.2 Fuel System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3.11.3 Cylinder Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

3.11.4 Exterior Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

3.11.5 Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

TP-6331 5/04

Table of Contents

Image 3
Contents Models Controller Advanced Digital Control ADCTP-6331 5/04 Engine Identification Product Identification InformationController Identification Generator Set Identification NumbersTable of Contents Table of Contents TP-6331 5/04 Safety Precautions and Instructions BatteryAccidental Starting Exhaust System Engine Backfire/Flash FireHazardous Voltage/ Electrical Shock Fuel System Hazardous NoiseHeavy Equipment Hot PartsMoving Parts 246242 VI Safety Precautions and Instructions TPTPS-6331 5/04 Introduction NameplateEPA and California Emission Certification Service Assistance Advanced Digital Control FeaturesSpecifications Generator EngineGenerator Set Components Generator Set ComponentsGenerator Set Operation Prestart ChecklistOperation Exercising Generator SetControls and Indicators Starting Generator SetStopping Generator Set Code Fault Description Check Fault ShutdownsResetting Controller after a Fault Shutdown Continuous Power ModeBattery Charger Operation Battery ChargerOperation TP-6331 5/04 Routine Maintenance Scheduled MaintenanceLubrication Service ScheduleOil Check Oil Change ProcedureLubrication System Low Oil Pressure ShutdownAir Cleaner Element and Precleaner Precleaner ServiceSpark Plugs Air Cleaner Components Paper Element ServiceCooling Air Intake and Exhaust Cooling SystemEZ-273000-J Circuit Protection Storage ProcedureBattery Cylinder LubricationExterior Preparation Scheduled Maintenance TP-6331 5/04 Troubleshooting Generator Set TroubleshootingIntroduction Fault Codes Battery Charger TroubleshootingTroubleshooting Ansi Appendix a AbbreviationsISO Page By Kohler Co. All rights reserved

12RES, 8.5RES specifications

The Kohler 8.5RES and 12RES generators are known for their robust reliability and efficiency, making them ideal solutions for both residential and light commercial applications. These generators are equipped with advanced technologies that ensure seamless power delivery during outages, giving users peace of mind.

The Kohler 8.5RES, with its 8.5 kW output, is perfect for homeowners who require backup power for essential appliances and systems. It efficiently powers refrigerators, lights, and heating or cooling systems, providing convenience when the grid is down. The 12RES, delivering 12 kW, caters to larger homes or small businesses, accommodating additional loads such as sump pumps and electric dryers.

One of the standout features of these generators is the Kohler Command PRO engine, designed for maximum performance and longevity. This engine operates with low noise levels, ensuring that any power interruption goes unnoticed. Both models come with an innovative digital control panel that simplifies operation and monitoring, allowing users to access critical information at a glance.

The Kohler 8.5RES and 12RES are equipped with the patented Automatic Voltage Regulation (AVR) technology. This feature maintains a steady voltage output to protect sensitive electronics from damage caused by power surges. The modular design of these units facilitates easy maintenance, with service intervals and replacement parts readily available.

For eco-conscious consumers, the Kohler generators meet EPA emission regulations, ensuring a cleaner energy solution. The units also offer a comprehensive sound-attenuated enclosure, resulting in quieter operation, making them suitable for use in suburban environments.

Installation is straightforward, with various connection options for natural gas and propane fueling. Both models come with a fully automatic transfer switch, providing seamless transition from grid to generator power. This ensures that critical systems are always operational during outages.

In summary, the Kohler 8.5RES and 12RES generators stand out for their reliability, advanced technology, and user-friendly features. Their powerful engines, efficient performance, and low emissions make them an excellent choice for anyone looking to invest in a dependable backup power solution. Whether for home use or light commercial needs, these generators provide the essential peace of mind that comes with knowing you have power when you need it most.