Kohler 12RES, 8.5RES manual Appendix a Abbreviations, Ansi

Page 33

Appendix A Abbreviations

The following list contains abbreviations that may appear in this publication.

A, amp

ampere

ABDC

after bottom dead center

AC

alternating current

A/D

analog to digital

ADC

analog to digital converter

adj.

adjust, adjustment

ADV

advertising dimensional

 

drawing

AHWT

anticipatory high water

 

temperature

AISI

American Iron and Steel

 

Institute

ALOP

anticipatory low oil pressure

alt.

alternator

Al

aluminum

ANSI

American National Standards

 

Institute

 

(formerly American Standards

 

Association, ASA)

AO

anticipatory only

API

American Petroleum Institute

approx.

approximate, approximately

AR

as required, as requested

AS

as supplied, as stated, as

 

suggested

ASE

American Society of Engineers

ASME

American Society of

 

Mechanical Engineers

assy.

assembly

ASTM

American Society for Testing

 

Materials

ATDC

after top dead center

ATS

automatic transfer switch

auto.

automatic

aux.

auxiliary

A/V

audiovisual

avg.

average

AVR

automatic voltage regulator

AWG

American Wire Gauge

AWM

appliance wiring material

bat.

battery

BBDC

before bottom dead center

BC

battery charger, battery

 

charging

BCA

battery charging alternator

BCI

Battery Council International

BDC

before dead center

BHP

brake horsepower

blk.

black (paint color), block

 

(engine)

blk. htr.

block heater

BMEP

brake mean effective pressure

bps

bits per second

br.

brass

BTDC

before top dead center

Btu

British thermal unit

Btu/min.

British thermal units per minute

CCelsius, centigrade

cal. calorie

CARB

California Air Resources Board

CB

circuit breaker

cc

cubic centimeter

CCA

cold cranking amps

ccw.

counterclockwise

CEC

Canadian Electrical Code

cert.

certificate, certification, certified

cfh

cubic feet per hour

cfm

cubic feet per minute

CG

center of gravity

CID

cubic inch displacement

CL

centerline

cm

centimeter

CMOS

complementary metal oxide

 

substrate (semiconductor)

cogen.

cogeneration

com

communications (port)

coml

commercial

Coml/Rec

Commercial/Recreational

conn.

connection

cont.

continued

CPVC

chlorinated polyvinyl chloride

crit.

critical

CRT

cathode ray tube

CSA

Canadian Standards

 

Association

CT

current transformer

Cu

copper

cu. in.

cubic inch

cw.

clockwise

CWC

city water-cooled

cyl.

cylinder

D/A

digital to analog

DAC

digital to analog converter

dB

decibel

dBA

decibel (A weighted)

DC

direct current

DCR

direct current resistance

deg., °

degree

dept.

department

dia.

diameter

DI/EO

dual inlet/end outlet

DIN

Deutsches Institut fur Normung

 

e. V.

 

(also Deutsche Industrie

 

Normenausschuss)

DIP

dual inline package

DPDT

double-pole, double-throw

DPST

double-pole, single-throw

DS

disconnect switch

DSAM

digital spark-advance module

DVR

digital voltage regulator

E, emer.

emergency (power source)

EDI

electronic data interchange

EFR

emergency frequency relay

e.g.

for example (exempli gratia)

EG

electronic governor

EGSA

Electrical Generating Systems

 

Association

EIA

Electronic Industries

 

Association

EI/EO

end inlet/end outlet

EMI

electromagnetic interference

emiss.

emission

eng.

engine

EPA

Environmental Protection

 

Agency

EPS

emergency power system

ER

emergency relay

ES

engineering special,

 

engineered special

ESD

electrostatic discharge

est.

estimated

E-Stop

emergency stop

etc.

et cetera (and so forth)

exh.

exhaust

ext.

external

FFahrenheit, female

fglass. fiberglass

FHM

flat head machine (screw)

fl. oz.

fluid ounce

flex.

flexible

freq.

frequency

FS

full scale

ft.

foot, feet

ft. lbs.

foot pounds (torque)

ft./min.

feet per minute

g

gram

ga.

gauge (meters, wire size)

gal.

gallon

gen.

generator

genset

generator set

GFI

ground fault interrupter

GND,

ground

gov.

governor

gph

gallons per hour

gpm

gallons per minute

gr.

grade, gross

GRD

equipment ground

gr. wt.

gross weight

H x W x D height by width by depth

HC

hex cap

HCHT

high cylinder head temperature

HD

heavy duty

HET

high exhaust temperature,

 

high engine temperature

hex

hexagon

Hg

mercury (element)

HH

hex head

HHC

hex head cap

HP

horsepower

hr.

hour

HS

heat shrink

hsg.

housing

HVAC

heating, ventilation, and air

 

conditioning

HWT

high water temperature

Hz

hertz (cycles per second)

IC

integrated circuit

ID

inside diameter, identification

IEC

International Electrotechnical

 

Commission

IEEE

Institute of Electrical and

 

Electronics Engineers

IMS

improved motor starting

in.

inch

in. H2O

inches of water

in. Hg

inches of mercury

in. lbs.

inch pounds

Inc.

incorporated

ind.

industrial

int.

internal

int./ext.

internal/external

I/O

input/output

IP

iron pipe

TP-6331 5/04

Appendix A-1

Image 33
Contents Models Controller Advanced Digital Control ADCTP-6331 5/04 Controller Identification Product Identification InformationGenerator Set Identification Numbers Engine IdentificationTable of Contents Table of Contents TP-6331 5/04 Safety Precautions and Instructions BatteryAccidental Starting Exhaust System Engine Backfire/Flash FireHazardous Voltage/ Electrical Shock Fuel System Hazardous NoiseHeavy Equipment Hot PartsMoving Parts 246242 VI Safety Precautions and Instructions TPTPS-6331 5/04 Introduction NameplateEPA and California Emission Certification Service Assistance Specifications Generator FeaturesEngine Advanced Digital ControlGenerator Set Components Generator Set ComponentsOperation Prestart ChecklistExercising Generator Set Generator Set OperationControls and Indicators Starting Generator SetStopping Generator Set Code Fault Description Check Fault ShutdownsResetting Controller after a Fault Shutdown Continuous Power ModeBattery Charger Operation Battery ChargerOperation TP-6331 5/04 Routine Maintenance Scheduled MaintenanceLubrication Service ScheduleLubrication System Oil Change ProcedureLow Oil Pressure Shutdown Oil CheckAir Cleaner Element and Precleaner Precleaner ServiceSpark Plugs Air Cleaner Components Paper Element ServiceCooling Air Intake and Exhaust Cooling SystemEZ-273000-J Circuit Protection Storage ProcedureBattery Cylinder LubricationExterior Preparation Scheduled Maintenance TP-6331 5/04 Troubleshooting Generator Set TroubleshootingIntroduction Fault Codes Battery Charger TroubleshootingTroubleshooting Ansi Appendix a AbbreviationsISO Page By Kohler Co. All rights reserved

12RES, 8.5RES specifications

The Kohler 8.5RES and 12RES generators are known for their robust reliability and efficiency, making them ideal solutions for both residential and light commercial applications. These generators are equipped with advanced technologies that ensure seamless power delivery during outages, giving users peace of mind.

The Kohler 8.5RES, with its 8.5 kW output, is perfect for homeowners who require backup power for essential appliances and systems. It efficiently powers refrigerators, lights, and heating or cooling systems, providing convenience when the grid is down. The 12RES, delivering 12 kW, caters to larger homes or small businesses, accommodating additional loads such as sump pumps and electric dryers.

One of the standout features of these generators is the Kohler Command PRO engine, designed for maximum performance and longevity. This engine operates with low noise levels, ensuring that any power interruption goes unnoticed. Both models come with an innovative digital control panel that simplifies operation and monitoring, allowing users to access critical information at a glance.

The Kohler 8.5RES and 12RES are equipped with the patented Automatic Voltage Regulation (AVR) technology. This feature maintains a steady voltage output to protect sensitive electronics from damage caused by power surges. The modular design of these units facilitates easy maintenance, with service intervals and replacement parts readily available.

For eco-conscious consumers, the Kohler generators meet EPA emission regulations, ensuring a cleaner energy solution. The units also offer a comprehensive sound-attenuated enclosure, resulting in quieter operation, making them suitable for use in suburban environments.

Installation is straightforward, with various connection options for natural gas and propane fueling. Both models come with a fully automatic transfer switch, providing seamless transition from grid to generator power. This ensures that critical systems are always operational during outages.

In summary, the Kohler 8.5RES and 12RES generators stand out for their reliability, advanced technology, and user-friendly features. Their powerful engines, efficient performance, and low emissions make them an excellent choice for anyone looking to invest in a dependable backup power solution. Whether for home use or light commercial needs, these generators provide the essential peace of mind that comes with knowing you have power when you need it most.