SECTION 3—OPERATION

DETAIL “A”

DETAIL “B”

DETAIL “C”

Drain

Jets

Drain Plug

Flow Water

Thermometer

Water Temperature Valve

FIGURE 3.4 Filling Tub

Hydromassage

CAUTION

Before starting hydromassage, water level MUST be completely above whirlpool jets otherwise damage to the motor/pump will result.

NOTE: For this procedure, refer to FIGURE 3.5.

1.Close the aerator by rotating the aerator valve two turns clockwise.

2.Open the whirlpool inlet by pushing the inlet plug in.

3.Open all whirlpool jets by pulling the center of the whirlpool jet out or rotating the center counterclockwise.

4.Fill the tub. Refer to Filling Tub on page 26.

5.After water level covers whirlpool jets (Detail “A”) and after bathing the resident, add ICCG Defoamer to bath water. Refer to Defoamer bottle for directions.

6.Push whirlpool On/Off button (Detail “B”) to start whirlpool jets.

7.Adjust the whirlpool aerator for desired water agitation by rotating the whirlpool aerator (Detail “C”).

8.After use, push whirlpool On/Off button to stop whirlpool jets (Detail “B”).

9.Drain tub (Detail “A”).

Part No 1150695

27

Recessed Side Entry Bath Tubs

Image 27
Contents Recessed Side Entry Bath Tubs Accessories Warning Table of Contents Troubleshooting Limited Warranty Special Notes Label Location These labels are located inside the service door3750 3800 Typical Product Parameters3750 Features3800 Important Safety Instructions InstallationGeneral Guidelines Plumbing ElectricalDisinfecting Maintenance and InspectionOperation Parts Installation About InstallationParts Information Stud Wall Pocket Installing the TubShower Wand Plumbing Model 3750 Only AB C Electrical and Plumbing Hook-up Locations on the TubElectrical Installation Electrical Installation Plumbing Installation Plumbing Installation Post Installation ChecklistOverview OperationEquipped Disinfecting the Tub Using the Closed Loop SystemClosing the Tub Door Opening/Closing the Tub DoorTub Operation Opening the Tub DoorWater Temperature Setting Water Temperature SettingFilling Tub Operating Shower/Massage WandFilling Tub HydromassageHydromassage Safety Inspection Checklists MaintenanceRemoving Soap Film and Hard Water Deposits Maintenance OverviewCleaning the Door Seal Gasket Cleaning Your TubRequired OZ Heavy Duty Cleaning ProcedureCalibrating the Disinfectant Flow Meter Calibrating the Disinfectant Flow Meter Maintenance Record Symptoms Faults Solution TroubleshootingUSA Limited Warranty