Dynasty Spas D-3000, D-2000 R i n g D i a g r a m, Factory Recommended G.F.C.I Load Center Wiring

Page 10

W i r i n g D i a g r a m

Factory Recommended G.F.C.I Load Center Wiring

House Breaker Box

 

RED (HOT)

 

BLK (HOT)

GRN

WHT

G.F.C.I. Breaker Box

Front View of G.F.C.I. (Square D)

GRN (GROUND)

WHT (NEUTRAL)

RED (HOT)

BLK (HOT)

WHT

GRN (GROUND)

BLK (HOT)

RED (HOT)

WHT

GRN (GROUND)

Note: The white neutral wire from the back of the G.F.C.I MUST be connected to an incoming line neutral. The internal mechanism of the G.F.C.I. requires this neutral connection. The G.F.C.I. will not work without it.

Bottom View of .GC.FI.

(Square D)

RED (HOT)

BLK (HOT)

WHT

WHT

Spa System Box

TB1

1

WHITE (NEUTRAL) 2

BLK (HOT)

3

RED (HOT)

4

GREEN (GROUND) 5

10

Image 10
Contents Page Installer DealerDyynnaassttyy SSppaass Ownneerrss Maannuuaall Dear Dynasty Spa Owner P o r t a n t S a f e t y I n s t r u c t i o n s SPA & Pool Institute S i c I n t r o d u c t o r y I n f o r m a t i o n T u p & D e l i v e r y G u i d e l i n e s T u p & D e l i v e r y G u i d e l i n e s Factory Recommended G.F.C.I Load Center Wiring R i n g D i a g r a mN e r a l P r e O p e r a t i o n I n s t r u c t i o n s To p S i d e C o n t r o l I n s t r u c t i o n s Diagnostic Messages Preset Filter CyclesFreeze Protection Preset Filter Cycles Auxiliary Panel optional System auxiliary panel optional Blower optional Standard and Economy ModeCirculation Pump optional LightFlow StandardEconomy IceMini Diverter Valve Single Filter Lt e r L o c a t i o nDual Filter Cleaning and Replacing Filter Cartridge Lt e r M a i n t e n a n c eCleaning Your Spa Water Filling Spa With WaterWater Testing BalanceAn Overview Monthly For Equipment Protection As NeededSkin Conditioning An Overview As NeededAlgae Control A i n i n g Yo u r S p a Winterize Your SPA N t e r i z i n g Yo u r S p aAsk Your Dealer About Using a Cover Caddy N t e r i z i n g S p a C o v e r sJets wont come on Spa Lights wont come onPump will not prime No heat or heat too lowMotor does not run Low water flowSpa is leaking Motor runs hotO s s a r y o f T e r m s Air Blower Air Loop Air Venturi CabinetO s s a r y o f T e r m s c o n t SkimmerA M o d e l s D e t a i l R e f e r e n c e C h a r t