Dimension One Spas Bay Collection manual Procedure for Winterizing

Page 59

2004 Bay Collection

Owner’s Manual

Procedure for Winterizing

1.Shut the power off to the system and make sure that it cannot be accidentally turned back on.

2.Remove filter elements from filter assembly.

3.Drain water from the system using the drain fitting and garden hose or you may use a submersible pump for faster water evacuation.

4.Open the equipment compartment and locate pumps and heater.

5.Remove all of the drain plugs from each pump.

6.Loosen unions on both sides of each pump, and the heater if applicable.

7.Remove the access panel below the Dynamic Jet Sequencer seat(s) and loosen all unions on each of the sequencer valves. Some models have more than one Dynamic Jet Sequencer seat, so you may have to remove more than one access panel. Remember, there are 6 sequencer valves per seat, which means that you will have to loosen 12 unions per seat.

8.Tip the system onto one side. (The system will have some water remaining, which will add to the weight). Be sure to have enough people available to safely lift the weight of your system. Do not tip system onto equipment bay side.

9.Close all jets, by turning jet faces counter clockwise.

10.Put on your protective goggles in order to protect eyes from air, water, antifreeze or debris exiting the jets or drains.

11.Insert the hose of a high-pressure air blower into the filter element fitting. Some models may have 2 filters. Begin with the left-hand filter fitting, which will help evacuate water from the circulation pump system. Then proceed to the right-hand filter fitting. When using air blower on single-filter systems or the right-hand fitting on dual filter systems, rotate each of the jet faces clockwise to open and counter-clockwise to close again. Do this to each jet face, one jet at a time. Be careful, as water will be coming out of each jet fitting as you perform this maneuver. Perform this operation, until no more water is coming from the jets.

12.Remove jet faces and insert the hose of a high-pressure air blower into each jet fitting. Continue this process, until no more water comes out of any jet fitting or drain fitting and you no longer hear water gurgling within the plumbing. Place all jet faces in a plastic bag and set aside until you are ready to use your system again.

13.Remove both bleeder valves from the top of the filter canister area. Place hose of a high-pressure air blower into the rear-most bleeder fitting first. Confirm that water mist is blowing from one or both of the circulation system return jets in the footwell of the system. You may also get some water mist blowing from the filter canister. Repeat this process with the front-most bleeder fitting. Confirm that water mist is blowing from the drain fittings of the jet pumps.

14.Place the hose of a commercial grade, wet-vacuum over each jet fitting, bleeder valve fitting, and drain fitting to draw out as much remaining standing water as possible.

15.Remove drain hose bib assembly from the outside bottom of the system.

16.Use the wet-vacuum to remove standing water from the pumps and any other fittings within the equipment compartment.

17.Once you are sure that all water is evacuated from the plumbing and equipment of the system, put the system back down in its normal position and repeat Step 10 and Step 11

18.Read all Directions and Safety Precautions on the Swimming Pool or Recreational Vehicle antifreeze bottle before opening and using. Ensure that it is non-toxic and safe for this use. Beware of and follow all safety precautions.

53

Image 59
Contents Page Dealer Information Date InstalledSpa Information My SpaSAFETY FIRST IMPORTANT SAFETY INSTRUCTIONS CSA SAFETY INFORMATIONDYNAMIC LED UNDERWATER LIGHTING Table of ContentsOPTIONAL HYDROSPORT AQUATIC FITNESS GEAR - SARENA BAY ONLY D1 REMOTE CONTROL OPTIONAL2004 Bay Collection Owner’s ManualADJUSTING WATER FLOW ADJUSTING THE FOUNTAIN - SARENA BAY ONLYADJUSTING THE FOUNTAIN - LOTUS BAY ONLY SPECIAL COLD WEATHER INSTRUCTIONSELECTRICAL SYSTEM TROUBLESHOOTING GUIDE2004 Bay Collection HEATING SYSTEMREAD AND FOLLOW ALL INSTRUCTIONS CAREFULLY Safety FirstIMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CSA SAFETY INFORMATIONAVERTISSEMENT NE PAS PLACER D’APPAREIL ÉLECTRIQUE LUMINAIRE, TÉLÉPHONE, RADIO, TÉLÉVISEUR, ETC. À MOINS DE 1.5 M DE CETTE CUVE DE RELAXATION DON’T block or sit on the filter recess area HyperthermiaDo’s and Don’ts Don’tDimension One Spas 2611 Business Park Drive Vista, CA Warning SignsFountain Bay Collection FeaturesUnderwater Switches Dynamic LED Underwater LightingSarena Bay Innovative Seating - For Revolutionary Design Features“No-float” angles Upright position Multiple Lounges Accommodate BioForm ReclinersBio-Wall / Bench Seat Pivot featurePivot Seat Bench Seatthe front part of the upper and lower Frontal Therapy SeatSport Zone Seat jetsLotus Bay Innovative Seating - For Accommodates BioForm Seat“No-float” angles Upright positionDesigned around specific muscle groups Jump SeatFeatures 9 adjustable and interchangeable the water, providing longerenjoyment without overheating Max Therapy + SeatContour Seat Additional Design Features - Sarena Bay Additional Design Features - Lotus Bay Synchronous Spa Lights - All Models Feature DescriptionsTop Side Control - All Models Dynamic Massage Sequencer - All ModelsAdjustable / Interchangeable fountain patterns Landscape focal point Underwater Switches - All ModelsFountain - Lotus Bay Weir Basket / Skimmer - All ModelsSarena Bay only Tactile TherapyPatent Pending - All ModelsHydroSport / OptiMounts - Sarena Bay Only Soft Tile Pillow - All ModelsIWatch - All Models NeckFlex Jet Pillow - All ModelsJet System Selector Valve - All Models Vision - All Models Infrared Sensor - All ModelsRemotely Control Spa Functions UltraPure Water Management System - All ModelsSonic Immersion System SIS Optional D1 Remote Control OptionalOptional HydroSport Aquatic Fitness Gear - Sarena Bay Only Scrolling Message Center Using The Top Side ControlsOperation JETS 1&2 Button Jet Pump 3 Button Water Feature Button Up / Down Buttons Light / Enter Button PROGRAM Button Heat Status Light Dimension One Spas ICON Logo→ Infrared Sensor Scrolling Message Center Messages Rinse Filters Clean Filters Change Water Change Vision CartridgeErroneous Temperature on the Display Spa Check UpOverheat Flashing Display and/or “Check Water Level” MODE” Ice CoolingSummer Mode Filter Cycle Start Time Setting the TimeProgramming the Scrolling Message Center Standby ModeTemperature Unit Selection Filter Cycle DurationNumber of Filter Cycles Pump Run TimeProgramming Lock Digital Display Window InvertControl Panel Lock Control Panel UnlockLIGHT Button Control Panel ResetDynamic Massage Sequencer Control Panel DescriptionSEQUENCE Button JETS ButtonSPEED Button BEGIN/PAUSE ButtonZone C Massage Zone DescriptionZone A Zone BOperating the Dynamic Massage Sequencer Adjusting the Fountain - Lotus Bay Only Adjusting the Fountain - Sarena Bay OnlyJet Selector Valves - Sarena Bay→ Adjusting Water Flowand can be used to suit Jet Selector Valves - Lotus BayStandard VCR Jets→ - Rotator Adjustable and Interchangeable JetsStandard VCR Jets→ - Directional Euro Jets - Directional Mini VCR Jets→ - RotatorMini VCR Jets→ - Directional a Mini VCR Jets→- RotatorTyphoon Jet - Directional Lotus Bay Only Green Status Light iWatch Perimeter LightingWater Drop Button Photo SensorInfrared Pocket-Tek Sensor Infrared D1 Remote Control SensorUsing iWatch Adjusting the Perimeter LightingDaylight Lighting Effect Power Saver ModeDaylight Operations Pocket-Tek Optional Remote Control OptionalIntegrated “Add-On’s” iWatch Auxiliary Module OptionalDraining Your Equipment Routine Equipment MaintenanceFilter Cleaning Cleaning the Skimmer CanisterCleaning the E-Z Lock Filter Screen and the Inner Filter Screen Cleaning the UltraPure CanisterSurface Care - Ultralife and Colored Shells Light Bulb ReplacementSurface Care Items Required for Winterizing Dimension One “ Envirotect” Skirts and Vinyl CoversSpecial Cold Weather Instructions Procedure for Winterizing Spring Time Startup Initial Startup Weir Skimmer/Filter 2004 Bay Collection Owner’s Manual Page Warranty Service Information Definition Glossary of TermsTerm Vision Cartridge Water Return Fittings Weir Skimmer Pump Selector Valve Serial Number Slice Valves Shutoff ValvesSmart Heat Temperature Sensor Top Side Control Panel Unions Venturi Heating System Troubleshooting GuideSymptom Problem2004 Bay Collection Electrical SystemWater System 2004 Bay Collection Owner’s Manual 2004 Bay Collection Owner’s Manual