Desa Ga3750a installation instructions Installing Blower Accessory in 36 or 42 Firebox

Page 4

4

INSTALLING BLOWER ACCESSORY IN 36" OR 42" FIREBOX

INSTALLING BLOWER ACCESSORY IN 36" OR 42"

FIREBOX

Continued

4.Attach green ground wire from power cord to blower housing using screw provided (see Figure 9). Tighten screws securely.

5.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 9). Using 2 screws provided, mount blower and tighten screws securely.

6.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

7.Locate the plastic hole plug installed in the 3/8" diameter open- ing in the lower right side of the firebox front panel (see Fig- ure 10). Remove the plastic plug and discard.

Exhaust Port

Top Mounting

Tab

Lower Rear Wall of

Firebox Wrapper

Screw

Screws

Blower

Figure 9 - Mounting Blower to Firebox

8.Place speed control against inner wall of front panel, pushing the plastic control shaft forward through the opening.

9.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise un- til it is tight against front panel. Place control knob provided on shaft (see Figure 11).

10.Turn on power to duplex outlet if previously turned off per the warning in column 2, page 3.

11.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plas- tic bushing provided into the 1 1/2" hole in the floor support on the exit side. Install the second plastic bushing provided into the 1 1/2" hole in the outer casing through which the power cord will exit (see Figures 10 and 12). Route power cord through both plastic bushings and plug the power cord into a wall receptacle near the firebox.

Speed Control

Control Shaft

Control Knob

Locknut

Figure 11 - Attaching Speed Control to Firebox

Plastic

Bushing

1 1/2" Hole

Plastic

Hole Plug

Floor

Supports

Wiring Diagram Decal 12" in Front of Blower

1 1/2" Hole

Figure 10 - Installing Plastic Bushing for Power Cord

Figure 12 - Location of Wiring Diagram Decal

For morevisit www..com

108319-01B

Image 4
Contents Installation Instructions Installing Blower Accessory in a 32 Firebox Mounting Blower to FireboxInstalling Blower Accessory in 36 or Firebox Operating the BlowerInstalling Blower Accessory in 36 or 42 Firebox Speed you desire Installing Blower Accessory Fireplace Systems Attaching Blower to Mounting BracketInstalling Blower Accessory in 32 Fireplace Systems Installing the Blower Installing Optional Blower Accessory Panel Wiring Diagram Decal Plastic Bushing Not a UPC

Ga3750a specifications

Desa GA3750A is a state-of-the-art technological solution designed for enhanced gas management in various applications. Built with user-friendly features and advanced mechanics, the GA3750A stands out in the market for its efficiency and reliability.

One of the main features of the Desa GA3750A is its efficient gas control mechanism. It is equipped with a high-precision pressure regulator that ensures stable and consistent gas flow. This mechanism is essential for applications requiring precise gas consumption, such as industrial processes and commercial kitchens. It minimizes wastage while maximizing performance efficiency.

The GA3750A utilizes cutting-edge materials, ensuring durability and longevity. Its corrosion-resistant construction not only prolongs the lifespan of the device but also makes it suitable for use in harsh environments. Whether in high-humidity areas or exposed to corrosive substances, the GA3750A maintains its integrity, delivering reliable service over time.

In terms of technology, the GA3750A incorporates smart monitoring systems that provide real-time data on gas usage. This feature allows users to track consumption patterns, offering insights that can lead to optimized operations and cost savings. The integration of IoT connectivity means that this device can be easily connected to advanced monitoring systems, enabling remote access and control.

Moreover, safety is prioritized in the design of the GA3750A. Equipped with multi-layer safety features, it includes automatic shut-off valves and leak detection sensors. In the event of a malfunction or detected leak, these safety measures activate to prevent potential hazards, ensuring that users can operate with peace of mind.

The GA3750A is also designed for ease of installation and maintenance. Its modular construction facilitates simple setup, and the components can be easily accessed for routine checks or repairs. This consideration for user convenience significantly reduces downtime and maintenance costs.

Overall, the Desa GA3750A embodies a blend of advanced technology and practical features, making it an essential tool for gas management in industrial and commercial settings. With its focus on efficiency, durability, and safety, the GA3750A is a market leader that meets the demands of modern applications effectively.