Desa Ga3750a Installing Blower Accessory in 36 or Firebox, Operating the Blower

Page 3

INSTALLING BLOWER ACCESSORY IN A 32" FIREBOX INSTALLING BLOWER ACCESSORY IN 36" OR 42" FIREBOX

3

INSTALLING BLOWER ACCESSORY IN A 32" FIREBOX

Continued

10.Turn on power to duplex outlet if previously turned off per the warning in step 1, page 2.

11.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation.

12.Peel off the backing paper and stick the supplied wiring dia- gram decal on the firebox bottom approximately 12" in front of the blower.

13.Replace bottom of firebox. Note: Make sure the back of the firebox bottom slides under the rear of the firebrick (lift the firebrick up if necessary.)

14.Reattach firebox bottom using 4 screws removed in step 1, page 2. Note: Discard the remaining hardware items.

15.Install the log set heater according to the installation instruc- tions supplied with the heater.

OPERATING THE BLOWER

Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire.

Note: Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions.

INSTALLING BLOWER ACCESSORY IN 36" OR 42"

FIREBOX

NOTICE: If a log set is installed in the firebox, discon- nect log set from gas supply and remove from firebox. Contact a qualified service person to do this.

Note: Appearance of firebox may vary depending on model.

1.If firebrick is installed, carefully lift and remove the concrete firebrick floor from the firebox (see Figure 5). Some model fireboxes require that you remove the side and rear panels first. Follow the directions below to remove the side and rear fire- brick panels for those fireboxes.

a.Using a Phillips screwdriver, remove the screw and retainer bracket at the top of the brick liner panel on the left side. Care- fully remove the left panel from the firebox (see Figure 6).

b.Repeat the removal steps for the brick liner panel on the right side.

c.Remove the screw and retainer bracket at the top of the brick liner panel at the rear of the firebox. IMPORTANT: Do not let panel fall after bracket has bee removed. Carefully re- move the rear panel from the firebox (see Figure 7).

d. Carefully lift and remove the concrete firebrick floor from the firebox if installed (see Figure 5).

2.Remove the firebox bottom.

a.Remove the 4 screws that secure the bottom of the firebox (see Figure 8).

b.Carefully raise and remove the firebox bottom from the firebox.

WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with the blower installa- tion. Failure to do this may result in serious injury.

3.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor.

Retainer Bracket

Screw

Firebrick Floor

Left Panel

Figure 5 - Removing Firebrick

Figure 6 - Removing Left Panel

Floor from Firebox

from Firebox

Screw

Retainer Bracket

 

Back

Screws

Panel

 

Figure 7 - Removing Back

Figure 8 - Removing Firebox

Panel from Firebox

Bottom

For more information, visit www.desatech.com

108319-01B

Image 3
Contents Installation Instructions Mounting Blower to Firebox Installing Blower Accessory in a 32 FireboxOperating the Blower Installing Blower Accessory in 36 or FireboxInstalling Blower Accessory in 36 or 42 Firebox Speed you desire Attaching Blower to Mounting Bracket Installing Blower Accessory Fireplace SystemsInstalling Blower Accessory in 32 Fireplace Systems Installing the Blower Installing Optional Blower Accessory Panel Wiring Diagram Decal Plastic Bushing Not a UPC

Ga3750a specifications

Desa GA3750A is a state-of-the-art technological solution designed for enhanced gas management in various applications. Built with user-friendly features and advanced mechanics, the GA3750A stands out in the market for its efficiency and reliability.

One of the main features of the Desa GA3750A is its efficient gas control mechanism. It is equipped with a high-precision pressure regulator that ensures stable and consistent gas flow. This mechanism is essential for applications requiring precise gas consumption, such as industrial processes and commercial kitchens. It minimizes wastage while maximizing performance efficiency.

The GA3750A utilizes cutting-edge materials, ensuring durability and longevity. Its corrosion-resistant construction not only prolongs the lifespan of the device but also makes it suitable for use in harsh environments. Whether in high-humidity areas or exposed to corrosive substances, the GA3750A maintains its integrity, delivering reliable service over time.

In terms of technology, the GA3750A incorporates smart monitoring systems that provide real-time data on gas usage. This feature allows users to track consumption patterns, offering insights that can lead to optimized operations and cost savings. The integration of IoT connectivity means that this device can be easily connected to advanced monitoring systems, enabling remote access and control.

Moreover, safety is prioritized in the design of the GA3750A. Equipped with multi-layer safety features, it includes automatic shut-off valves and leak detection sensors. In the event of a malfunction or detected leak, these safety measures activate to prevent potential hazards, ensuring that users can operate with peace of mind.

The GA3750A is also designed for ease of installation and maintenance. Its modular construction facilitates simple setup, and the components can be easily accessed for routine checks or repairs. This consideration for user convenience significantly reduces downtime and maintenance costs.

Overall, the Desa GA3750A embodies a blend of advanced technology and practical features, making it an essential tool for gas management in industrial and commercial settings. With its focus on efficiency, durability, and safety, the GA3750A is a market leader that meets the demands of modern applications effectively.