Desa Ga3750a installation instructions Installing Blower Accessory in 32 Fireplace Systems

Page 7

INSTALLING BLOWER ACCESSORY IN 32" FIREPLACE SYSTEMS

7

INSTALLING BLOWER

ACCESSORY IN 32"

FIREPLACE SYSTEMS

Continued

6.Place the blower against lower rear wall of firebox outer wrap- per with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 18, page 6). Using 2 screws provided, mount blower and tighten screws securely.

7.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

8.Place control knob provided on plastic control shaft of speed control.

9.Mount the speed control on the front leg of the left floor support bracket using 2 screws provided (see Figure 19). Note: Some remote ready fireplace models have the gas control located near the left floor support bracket. For these models, mount the blower speed control onto the right floor support bracket.

10.Plug in blower power cord.

a.If your fireplace system is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1.5" hole in the floor support bracket on the exit side (see Figure 20). Install the second plas- tic bushing provided into the 1.5" hole in the outer casing through which the power cord will exit. Route power cord through both plastic bushings and plug the power cord into a properly grounded 3-prong wall receptacle near the firebox.

b.If your fireplace system installation is recessed and if an outlet is not installed in your fireplace, you must install the GA3555 Outlet kit with cover in your fireplace which will sup- ply a convenient 3-prong grounded electrical outlet for your blower. Refer to the installation manual provided with the model GA3555 accessory for instructions on wiring the duplex outlet. Note:A qualified installer must make all electrical connections.

Left Floor

Support

Bracket

Speed Control

Screws

Control

KnobControl

Shaft

Figure 19 - Attaching Speed Control to Firebox

11.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise before continuing.

CAUTION: Never touch the blower wheel while in operation.

12.Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 3" to the right of the blower speed control (Figure 21).

Right Floor

Support Bracket

Plastic

Bushing

Figure 20 - Installing Plastic Bushing for Power Cord

WARNING: Never attempt to service heater while it

 

is plugged in, operating, or hot. Burns and electrical

 

shock could result. Only a qualified service person

 

should service or repair heater.

 

If any of the original wire as supplied with the appliance must be

 

replaced, it must be replaced with 105° C wire or it’s equivalent.

 

WARNING: Label all wires prior to disconnection

 

when servicing controls. Wiring errors can cause im-

Wiring

proper and dangerous operation. Verify proper opera-

tion after servicing.

Diagram

Variable

 

Fan Switch

 

 

 

Off

Black

On

110/115

 

Black

Blower

V.A.C.

Black

 

 

Motor

 

 

 

Black

 

Green

 

 

 

 

 

White

White

120 Vac. 60 Hz. . 78 Amps

 

 

 

 

 

 

 

 

 

 

101584-05

DESA, Bowling Green, KY

Figure 21 - Location of Wiring Diagram Decal 3" from Blower

For more information, visit www.desatech.com

108319-01B

Image 7
Contents Installation Instructions Mounting Blower to Firebox Installing Blower Accessory in a 32 FireboxOperating the Blower Installing Blower Accessory in 36 or FireboxInstalling Blower Accessory in 36 or 42 Firebox Speed you desire Attaching Blower to Mounting Bracket Installing Blower Accessory Fireplace SystemsInstalling Blower Accessory in 32 Fireplace Systems Installing the Blower Installing Optional Blower Accessory Panel Wiring Diagram Decal Plastic Bushing Not a UPC

Ga3750a specifications

Desa GA3750A is a state-of-the-art technological solution designed for enhanced gas management in various applications. Built with user-friendly features and advanced mechanics, the GA3750A stands out in the market for its efficiency and reliability.

One of the main features of the Desa GA3750A is its efficient gas control mechanism. It is equipped with a high-precision pressure regulator that ensures stable and consistent gas flow. This mechanism is essential for applications requiring precise gas consumption, such as industrial processes and commercial kitchens. It minimizes wastage while maximizing performance efficiency.

The GA3750A utilizes cutting-edge materials, ensuring durability and longevity. Its corrosion-resistant construction not only prolongs the lifespan of the device but also makes it suitable for use in harsh environments. Whether in high-humidity areas or exposed to corrosive substances, the GA3750A maintains its integrity, delivering reliable service over time.

In terms of technology, the GA3750A incorporates smart monitoring systems that provide real-time data on gas usage. This feature allows users to track consumption patterns, offering insights that can lead to optimized operations and cost savings. The integration of IoT connectivity means that this device can be easily connected to advanced monitoring systems, enabling remote access and control.

Moreover, safety is prioritized in the design of the GA3750A. Equipped with multi-layer safety features, it includes automatic shut-off valves and leak detection sensors. In the event of a malfunction or detected leak, these safety measures activate to prevent potential hazards, ensuring that users can operate with peace of mind.

The GA3750A is also designed for ease of installation and maintenance. Its modular construction facilitates simple setup, and the components can be easily accessed for routine checks or repairs. This consideration for user convenience significantly reduces downtime and maintenance costs.

Overall, the Desa GA3750A embodies a blend of advanced technology and practical features, making it an essential tool for gas management in industrial and commercial settings. With its focus on efficiency, durability, and safety, the GA3750A is a market leader that meets the demands of modern applications effectively.