Chicago Electric 68316 Double Insulated Tools Tools with Two Prong Plugs, Extension Cords

Page 7

Grounding

TO PREVENT ELECTRIC SHOCK AND DEATH

FROM INCORRECT GROUNDING WIRE CONNECTION:

Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Do not use the tool if the power cord or

plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Double Insulated Tools: Tools with Two Prong Plugs

1.Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies

OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code.

2.Double insulated tools may be used in either of the 120 volt outlets shown in the preceding illustration.

(See Outlets for 2-Prong Plug.)

Outlets for 2-Prong Plug

Extension Cords

SAFETY

SETUP

1.Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. (See Table A.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)

4.When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Table A.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Table A.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in

Canada) to indicate it is acceptable for outdoor use.

7.Make sure the extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect the extension cords from sharp objects, excessive heat, and damp or wet areas.

Table A: RECOMMENDED MINIMUM WIRE

GAUGE FOR EXTENSION CORDS* (120/240 VOLT)

NAMEPLATE

EXTENSION CORD

AMPERES

 

LENGTH

 

(at full load)

25’

50’

75’

100’

7.1 – 12.0

18

14

12

10

12.1 – 16.0

14

12

10

-

16.1 – 20.0

12

10

-

-

*Based on limiting the line voltage drop to five volts at

150% of the rated amperes.

OPERATION

Symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

 

 

 

n0 xxxx/min.

No Load Revolutions

per Minute (RPM)

MAINTENANCE

SKU 68316

For technical questions, please call 1-800-444-3353.

Page 7

Image 7
Contents Save this Manual Electrical safety Table of ContentsGeneral Power Tool Safety Warnings Work area safetyPower tool use and care Personal safetySafety Circular Saw Safety Warnings ServiceSafety Setup Operation Maintenance Circular Saw Safety Warnings Vibration Safety Grounding SymbologyDouble Insulated Tools Tools with Two Prong Plugs Extension CordsSetup Before Use AssemblySafety Setup Operation SpecificationsFunctions Operating Instructions Tool Set Up Blade InstallationSetup Operation Maintenance Work Piece and Work Area Set Up Using Lubrication UnitOperation Maintenance Feed Speed General Operating InstructionsCutting Techniques 8inShaped Plate Maintenance and Servicing Cleaning, Maintenance, and LubricationProblem Possible Causes Likely Solutions TroubleshootingParts List and Diagram Parts ListAssembly Diagram Limited 90 Day Warranty