4. Appendices

Adjusting the expression pedal

(Calibration)

If you find the expression pedal difficult to use, perform this pro- cedure so that the pedal will function optimally. For example if the effect does not reach maximum when the pedal is advanced all the way, or does not reach minimum when the pedal is re- turned all the way, use the following procedure to make the ap- propriate adjustments.

When making adjustments, use your hand to move the pedal. Accurate calibration may not be possible if you use your foot to operate the pedal.

1.Turn on the power while simultaneously holding down the EXIT switch and the PEDAL switch. The Multi-display will show “PEDAL” for approximately one second, and will then indicate “MIN.”

2.Slowly return the pedal to the full back position. When it stops, release your hand and press the WRITE switch. The Multi- display will change from “MIN” to “MAX.”

If you decide to halt the adjustment procedure, press the EXIT switch. The power-on display will appear, and you will enter Program mode.

3.Slowly advance the pedal. When it stops, release your hand and press the WRITE switch.

2. press slowly

3. press slowly

The Multi-display will indicate “COMPLT” for approximately one second. Then the power-on display will appear, and you will enter Program mode.

After the adjustment procedure has been completed, verify the operation of the pedal.

Select an effect that will make it easy to verify the adjustment. For example, set the Pedal effect to the VOLUME effect, set the value to 0, and check the MIN level when the pedal is returned all the way.

If you make a mistake during the calibration procedure, the Multi- display will indicate “ERROR,” and you will return to the screen before the adjustment (the “MIN” display). If the “ERROR” dis- play appears for repeated attempts, a malfunction may have oc- curred. In this case, please contact your dealer.

Restoring the user programs to the

factory settings (Reload)

1.Turn on the power while simultaneously holding down the EXIT switch and the PROG/FX SELECT switch. The Multi- display will indicate “RELOAD?

2.Press the WRITE switch. The Multi-display will change to “RELOAD,” and the reload operation will begin. When the reload operation is completed, the display will indicate “COMPLT” for approximately one second. Then the power- on display will appear, and you will enter Program mode.

Never turn off the power during the reload operation.

When you perform the reload operation, all user programs will be rewritten. Rhythm settings will also be initialized.

Troubleshooting

If you suspect a malfunction, please check the following points first. If this does not resolve the problem, contact a nearby Korg dealer.

1. Power does not turn on

Are batteries installed? Alternatively, is the AC adapter con- nected to an AC outlet? (p.5)

Is a mono cable connected to the INPUT jack? (p.5)

2. No sound

Are your guitar, amp, and headphones connected to the cor- rect jack? (p.5)

Is your amp turned on, and is it set accordingly?

Is one of your connection cables broken?

Has the MASTER VOL (master volume) of the AX100G been turned down? (p.6)

Is the program level of the AX100G set to “0” or to a low value? (p.9, 16)

Is the Level of the Drive Amp effects set to “0” or to a low value?

Is the volume of your guitar turned down?

Is the AX100G muted?

If VOLUME is selected for the PEDAL effect, has the pedal been returned to the full back position?

3. Effects are not applied

Is the AX100G bypassed? (p.6)

Are the effects used by the program turned on? (p.6)

4. Rhythm does not function

Are you in Program mode or in Effect Select mode? The rhythm will not function in Phrase Trainer mode.

Is the rhythm output level set to “0”? (p.7)

5. Pedal does not function

Have you selected a program that uses an effect in the PEDAL effect mode? (p.6)

Is the pedal indicator lit? (p.4, 7)

Try calibrating the expression pedal. (p.11)

4. Appendices

11

Image 11
Contents G J Printing conventions in this manual PrecautionsIntroduction ContentsRear panel Front and rear panelFront panel Modes of the AX100G Installing the batteriesTurn on the power Playing the AX100GProgram mode Rhythm Effect Select modeEntering Effect Select mode Exiting Effect Select modePhrase Trainer mode Editing the Drive Amp effect example EditingEditing the effects Drive Amp effect Quick Edit functionAvailable characters Using the TAP switch to edit the delay timeEditing Editing other effects Modifying the program nameAppendices Adjusting the expression pedal CalibrationRestoring the user programs to Factory settings Reload TroubleshootingDRIVE·AMP Drive Amp effects Main specificationsCannot write Multi-display indicates Error Effect parametersIntelligent Pitch Shifter MOD Modulation effectsFeed Back Pedal Pedal effectMIX/LEVEL Tone AMB Ambience effectSample and play TimeName Rhythm Pattern ListCabi Cabinet effect Noise Reduction, Program LevelPreset Program Parameter List Korg INC