MAINTENANCE
Adjusting Bucket Level Indicator
With various tractor tire options or attachments, it may be necessary to adjust bucket level indicator tube up or down on bucket cylinder tube. Tractor must be on level surface with attachment flat on surface. Loosen tightener band and adjust level guide tube along bucket cylinder until end of guide tube is flush with end of rod. Tighten band.
Daily Maintenance
Regular maintenance of your loader and hydraulic system will insure maximum loader efficiency and long life.
1.Check fluid level of tractor hydraulic system before starting each day’s operation. If necessary, add hydraulic oil as recommended in your tractor operator’s manual.
2.Daily, unless conditions justify more frequently, lubricate all twelve grease fittings; one at each end of lift boom arms and one at rod and base ends of each lift and bucket cylinder.
3.After every ten hours of operation, check all hardware and tighten where required.
4.Replace hoses immediately if they are damaged by a cut or scrape, extruded at the fittings or leaking. Hydraulic oil leaks should be repaired promptly to avoid loss of oil and serious personal injury from escaping oil.
Escaping hydraulic fluid under pressure can penetrate skin, causing serious personal injury.
•DO NOT use your hand to check for leaks. Use a piece of wood or cardboard and wear eye protection to search for leaks.
•Stop engine and relieve pressure before connecting or disconnecting lines.
•Tighten all connections before starting engine or pressurizing lines.
NOTE: If any fluid is injected into skin, obtain medical attention immediately or gangrene may result.
1945 01/11 | Maintenance Section |
© 2011 Alamo Group Inc.