Cal Spas LTR20101000 manual Periodic Reminder Messages, Diagnostic Messages

Page 20

18

Operating SpaYour

Periodic Reminder Messages

Press the “Mode” button to reset a displayed reminder.

Message

Frequency

Action Required

rPH

Every 7 days

Test and adjust chemical levels per manufacturer’s instructions.

 

 

 

 

rSA

Every 7 days

Test and adjust chemical levels per manufacturer’s instructions.

 

 

 

 

rCL

Every 30 days

Remove, clean, and reinstall filter per manufacturer’s instructions.

 

 

 

 

rtg

Every 30 days

Test and reset GFCI per manufacturer’s instructions. Drain and refill

 

 

spa per manufacturer’s instructions.

 

 

 

 

rdr

Every 90 days

Drain and refill spa per manufacturer’s instructions.

 

 

 

 

rCO

Every 180 days

Clean and condition spa cover.

 

 

 

 

rCH

Every 365 days

Install a new filter.

 

 

 

 

Diagnostic Messages

 

 

 

 

 

 

Message

Meaning

 

Action Required

 

 

 

No message

1) Spa temperature is unknown.

1) After pump has been running for 2 minutes

on display

 

 

temperature will be displayed.

 

2) Spa is in Economy or Sleep

2) In Economy or Sleep mode, the pump may be off

 

mode.

 

for hours outside a filter cycle. If you wish to see the

 

 

 

current spa temperature, either switch to Standard

 

 

 

mode or turn Jets1 on for at least two minutes.

 

3) Power has been cut off to the

3) The control panel will be disabled until power

 

spa.

 

returns. Spa settings and time of day will be

 

 

 

preserved for 30 days with a battery back-up.

 

 

 

BUF

Internal problem detected.

Repair required. Contact your dealer or service

 

 

 

organization.

 

 

 

dr

Insufficient water detected in

Check water level in spa. Refill if necessary. Make

 

heater. Spa will be shut down for

sure pumps are been primed and filter cartridges are

 

15 minutes.

 

clean. Press any button to reset or wait 15 minutes

 

 

 

and spa will automatically reset. If message spa does

 

 

 

not reset, call your dealer or service organization.

 

 

 

dry

Insufficient water detected in

Follow directions for dr message and press any button

dY

heater. Spa is shut down.

to reset spa. Spa will not automatically reset when dry

 

(Displays on third occurrence of dr

or dY is displayed.

 

 

 

message.)

 

 

 

 

 

Ec

Indicates heater is in Economy

None.

 

Mode.

 

 

--F or --C

Temperature unknown

 

After the pump has been running for two minutes, the

 

 

 

temperature will be displayed.

 

 

 

HL

A difference in readings between

Make sure spa is filled to proper level and that

HFL

temperature sensors has been

pumps are primed and filter cartridges are clean. If

 

detected indicating a possible water

message does not reset, call your dealer or service

 

flow problem.

 

organization.

 

 

 

IC

Potential freeze condition detected.

No action required. The pumps and the blower will

ICE

 

 

automatically activate regardless of spa status.

 

 

 

 

2010 Portable Spa

www.calspas.com

LTR20101000, Rev. C

Image 20
Contents LTR20101000, Rev. C 2/28/10 Cleaning and Maintenance Using the Entertainment SystemOperating Your Spa Appendix Clear Water PlanImportant Safety Instructions This FirstRead First!This Preparing for Your New Portable Spa Planning the Best LocationForYour New Portable Spa Preparing a Good FoundationVolt Electrical Installation Testing the Gfci BreakerGfci and Wiring Requirements Spa240V Gfci and Wiring Requirements System High Power ConfigurationSpa Model Gfci Required Wires Required Your New Portable SpaApplies to 6300 systems Electrical Installation for 11 kW HeaterPreparing forYour New Portable Spa Gfci Wiring Diagram Gas Heater Hook up Your New Portable Spa Preparing forYour New Filling and Powering Up Your Portable SpaPortable Spa Second method will remove a large air lock within the pump Priming the PumpNew Portable Spa Temperature Adjustment Operating Your SpaOperating SpaYour 5100, 6200 and 6300 Electronic Control OperationSwitching Modes Setting Filtration CyclesStandard, Economy and Sleep Heating Modes JetsStandard, Economy, Sleep, and Standby Modes Electronic Control OperationTime Setting the Temperature Lock Preset Filter CyclesInvert Locking the PanelFreeze Protection Clean up CycleOzone Standard configuration Spa Models with 3-pump system Sounds Good System OperationAuxiliary Control Panels Air blower control Two button jets control 6200/6300Message Frequency Action Required Diagnostic MessagesPeriodic Reminder Messages Stby Message Meaning Action RequiredSnb Sns Electrical Power Efficiency Jets Diverter KnobsWaterfalls Air VenturisAdjustable Therapy System Wireless Spa MonitorLED Perimeter Lighting Contents of this section Clear Water PlanClear PlanWater Key to Clear WaterTesting and Adjusting Spa Water Clear Water PlanBalancing the Total Alkalinity Balancing the pHUsing Chlorine as a Sanitizer Using Bromine as a SanitizerSanitation Adding Sanitizer Tablets to the Chemical ChamberChemical Safety Shocking the WaterFilter Cleaning About the Pure XL Water SanitizerBather Load Starting the Spa with Fresh WaterMaintenance Schedule Cal Zone Quest Ozonator Cal Clarity Bromine GeneratorStart Up Day One MondayAdjusting The Proper Bromine Levels Once a WeekWater Plan Troubleshooting Water Clarity ProblemsClear Spa Cover Cleaning and MaintenanceRemoving and Reseating the Pillows Cleaning and Replacing the Filter Draining Your Portable SpaFreeze damage is not covered by your warranty Winterizing Cold Climate DrainingVacation Care Continuous water flow and drainageSpa Shell Cleaning Your SpaSpa Cover and Pillows Jet Removal and Replacement Using the Entertainment System Listening to the RadioPlaying a CD Inserting and Ejecting a DiskTheUsing SystemEntertainment Using the iPod Docking StationProgramming the Universal Remote Control Device Manufacturer Code TypeAbout the SunBriteTV Monitor Using the iSound Remote Music SystemUsing the Entertainment System Replacement Parts AppendixValves Pillows DrainsWaterfalls FiltersReplacement Cabinet Panels LightsOzone Cartridges Pure XL UV Water SanitizerDiamond Series CoversAvalon Series Fitness Series D950N / D965N 93 x D963S / D950SFamily II Series Galaxy SeriesVictory Xtreme Series VX901 72 xKeeping Fit with your Spa Ultimate Fitness Series Exercise ProgramConnecting the Exercise Equipment Troubleshooting Symptom Possible Causes Possible SolutionsSymptom Water Problems Possible Causes Possible SolutionsSymptom Possible Causes Possible Solutions Pump Problems Pump does not workCal Spas Chemicals Portable Spas WarrantyAppendix Manufacturer Warranty Warranty Registration Locating the product serial number