Cal Spas LTR20101000 manual Troubleshooting, Symptom Possible Causes Possible Solutions

Page 54

52 Appendix

Troubleshooting

Symptom

Possible Causes

 

Possible Solutions

System / Power Problems

 

 

 

System does not work

Power is turned off

 

Reset spa

 

Control pad and spa

No electrical power to spa

 

Turn on or reset the GFCI circuit breaker.

equipment do not

 

 

If this does not solve the problem, have

operate

 

 

a qualified electrician check the electrical

 

 

 

service.

 

 

 

 

 

The 20 or 30A fuse, depending on

 

Contact your dealer

 

the system, has blown

 

 

The spa does not turn

Spa is trying to heat up

 

Check the temperature setting is in

off

 

 

Standard mode

 

 

 

 

 

Spa is in filter cycle

 

Normal. No adjustment necessary

 

 

 

 

 

Spa is in Standard mode

 

Check setting

Control panel displays

An error may have has occurred

 

See Diagnostic Messages on page 18 for

a message

 

 

message code meanings

GFCI breaker trips

Improper wiring to spa or GFCI

 

Consult with a qualified electrician

repeatedly

breaker is defective

 

 

 

 

 

 

 

There is a defective component on

 

Contact your dealer

 

the spa

 

 

Heat Problems

 

 

 

Spa does not heat

Heating mode not selected

 

See control panel instructions on pages

 

 

 

12 through 16

 

 

 

 

 

Water level is too low

 

Add water to correct level

 

 

 

 

 

No electrical power to spa

 

Turn on or reset the GFCI circuit breaker.

 

 

 

If this does not solve the problem, have

 

 

 

a qualified electrician check the electrical

 

 

 

service.

 

 

 

 

 

Heater is defective

 

Contact your dealer

 

 

 

 

 

Gate valve is partially or fully closed

 

Open gate valves. Note: Never operate

 

 

 

your spa with the gate valves closed!

Spa gets warm but

Thermostat has been turned down

 

Set control panel to a higher temperature

does not get hot

 

 

 

Insufficient filtration time

 

Increase filtration time

 

 

 

 

 

 

 

Water level is too low

 

Add water to correct level

 

 

 

 

 

No electrical power to spa

 

Turn on or reset the GFCI circuit breaker.

 

 

 

If this does not solve the problem, have

 

 

 

a qualified electrician check the electrical

 

 

 

service.

 

 

 

 

 

Dirty filter cartridge

 

Clean filter cartridge

 

 

 

 

 

Gate valves closed

 

Open gate valves

 

 

 

 

 

Spa cover improperly positioned

 

Align spa cover

Spa gets too hot

Filtration time is set too long

 

Reduce filtration cycles, especially during

 

 

 

summer months

 

 

 

 

2010 Portable Spa

www.calspas.com

LTR20101000, Rev. C

Image 54
Contents LTR20101000, Rev. C 2/28/10 Operating Your Spa Cleaning and MaintenanceUsing the Entertainment System Appendix Clear Water PlanImportant Safety Instructions This FirstRead First!This ForYour New Portable Spa Preparing for Your New Portable SpaPlanning the Best Location Preparing a Good FoundationGfci and Wiring Requirements Volt Electrical InstallationTesting the Gfci Breaker SpaSpa Model Gfci Required Wires Required 240V Gfci and Wiring RequirementsSystem High Power Configuration Your New Portable SpaElectrical Installation for 11 kW Heater Preparing forYour New Portable SpaApplies to 6300 systems Gfci Wiring Diagram Gas Heater Hook up Your New Portable Spa Filling and Powering Up Your Portable Spa Portable SpaPreparing forYour New Priming the Pump New Portable SpaSecond method will remove a large air lock within the pump Operating SpaYour Temperature AdjustmentOperating Your Spa 5100, 6200 and 6300 Electronic Control OperationStandard, Economy and Sleep Heating Modes Switching ModesSetting Filtration Cycles JetsElectronic Control Operation TimeStandard, Economy, Sleep, and Standby Modes Invert Setting the Temperature LockPreset Filter Cycles Locking the PanelClean up Cycle OzoneFreeze Protection Auxiliary Control Panels Standard configuration Spa Models with 3-pump systemSounds Good System Operation Air blower control Two button jets control 6200/6300Diagnostic Messages Periodic Reminder MessagesMessage Frequency Action Required Message Meaning Action Required Snb SnsStby Electrical Power Efficiency Waterfalls JetsDiverter Knobs Air VenturisAdjustable Therapy System Wireless Spa MonitorLED Perimeter Lighting Clear PlanWater Contents of this sectionClear Water Plan Key to Clear WaterBalancing the Total Alkalinity Testing and Adjusting Spa WaterClear Water Plan Balancing the pHSanitation Using Chlorine as a SanitizerUsing Bromine as a Sanitizer Adding Sanitizer Tablets to the Chemical ChamberChemical Safety Shocking the WaterFilter Cleaning About the Pure XL Water SanitizerBather Load Starting the Spa with Fresh WaterMaintenance Schedule Start Up Cal Zone Quest OzonatorCal Clarity Bromine Generator Day One MondayAdjusting The Proper Bromine Levels Once a WeekTroubleshooting Water Clarity Problems ClearWater Plan Cleaning and Maintenance Removing and Reseating the PillowsSpa Cover Cleaning and Replacing the Filter Draining Your Portable SpaVacation Care Freeze damage is not covered by your warrantyWinterizing Cold Climate Draining Continuous water flow and drainageCleaning Your Spa Spa Cover and PillowsSpa Shell Jet Removal and Replacement Playing a CD Using the Entertainment SystemListening to the Radio Inserting and Ejecting a DiskProgramming the Universal Remote Control TheUsing SystemEntertainmentUsing the iPod Docking Station Device Manufacturer Code TypeUsing the iSound Remote Music System Using the Entertainment SystemAbout the SunBriteTV Monitor Replacement Parts AppendixValves Waterfalls PillowsDrains FiltersOzone Cartridges Replacement Cabinet PanelsLights Pure XL UV Water SanitizerCovers Avalon SeriesDiamond Series Fitness Series D950N / D965N 93 x D963S / D950SFamily II Series Galaxy SeriesVictory Xtreme Series VX901 72 xKeeping Fit with your Spa Ultimate Fitness Series Exercise ProgramConnecting the Exercise Equipment Troubleshooting Symptom Possible Causes Possible SolutionsSymptom Water Problems Possible Causes Possible SolutionsSymptom Possible Causes Possible Solutions Pump Problems Pump does not workCal Spas Chemicals Warranty AppendixPortable Spas Manufacturer Warranty Warranty Registration Locating the product serial number