Pump On/Off

This button allows the user to turn on and off the ATS™ seat pump. Press this button once to turn the pump on. Once on, the green LED light on the control panel will illuminate, indicating that the system is operational. To turn

off the pump, press the “PUMP ON/OFF” button a second time. Note: The pump must be on prior to operating any other features of this system.

Pulse Mode

This button allows the user to turn the ATS™ massage control on and off. Press the pulse button once to turn on the massage control. Once pressed, the orange LED in position number 1will light, indicating the number one pulse mode. Each press of either the up or down button will move the orange LED up or down to the next pulse mode.

Note: Allow one second between each button press. Pressing the button quickly may cause improper operation. To turn the pulse mode off and return to normal pump operation, press the “PULSE MODE” button a second time.

Up

This button allows the user to cycle up from one through seven massage modes one at a time. Each mode offers a different pulsating massage. Some modes are faster than others, so just cycle through them to find the massage you like best.

Down

This button allows the user to cycle down through all seven massage modes, one at a time.

Time Reset Mode

Pulse mode will normally run for 15 minutes then automatically shut off. For another 15-minute session, press the “PUMP ON/OFF” button and the “PULSE MODE” button. A green LED will blink and the pump will run on high-speed mode as part of a 15-minute cool down period. After that, the pump will stop automatically and the green LED light on the panel will continue to

Operating Your Spa

blink for one minute then shut off automatically. After the second 15-minute session, the system will run through a cool down cycle for up to two hours. In this cool down mode, the user will only be able to operate the pump (by again pressing the “PUMP ON/OFF” button). However, the massage mode will remain off until the cool down mode is completed.

Pulse Mode System

Pulse mode system will shut off for two hours unless reset by the following procedure. During this time the pump will run at a maximum speed.

In the off position, press the “PULSE MODE” button once.

The green power light will flash to indicate reset.

Multi-Colored Spa Light

Operation

1.Turn the spa light on by pressing the “LIGHT” button on the topside control panel.

2.To filter through the different color choices, press the button on and off. Each time you press the button, you advance to the next color.

3.To turn the spa light off when not in use, press the “LIGHT” button.

Aromatherapy

This optional accessory is very easy to use. Unscrew the cap on the aromatherapy chamber and drop in a bag of scented aromatherapy beads and replace the cap.

Waterfalls

Some spa series include optional waterfalls. When the booster pump is on, turn the knob near the waterfall, or rotate the dial on top of the waterfall. Water will immediately start flowing through it.

2008 Portable Spa Owner’s Manual

Page 19

LTR20081000, Rev. B

Image 21
Contents LTR20081000, Rev. B 28/08 Cleaning and Maintenance Water Quality MaintenanceUsing the Entertainment System Read This FirstRead This First Important Safety InstructionsBasic Spa Information Hyperthermia DangerRead This First Preparing for Your New Portable Spa Planning the Best LocationPreparing a Good Foundation Gfci and Wiring Requirements Volt Electrical InstallationTesting the Gfci Breaker Configuring the 6300 Control SystemSpa Model Gfci Required Wires Required Gfci Wiring Diagram Gas Heater Hook up Preparing for Your New Portable Spa Filling and Powering Up Your Portable Spa 5100, 6200 and 6300 Electronic Control Operation Operating Your SpaDiagnostic Messages Meaning Setting Filtration CyclesLight OptionYour dealer or service organization Initial Start-up Electronic Control OperationTime Standard, Economy, Sleep, and StandbySetting the Temperature Lock Preset Filter CyclesClean up Cycle InvertDiagnostic Messages Meaning Action Required Periodic Reminder MessagesMessage Frequency Action Required Dry Message Meaning Action RequiredOr --C StbyWireless Spa Monitor Auxiliary Panel Configuration FunctionsAuxiliary Control Operation Air Venturis Adjustable Jets Diverter KnobsMulti-Colored Spa Light Operation Adjustable Therapy SystemAromatherapy WaterfallsCal Spas Clear Water Plan Water Quality MaintenanceAlternative Sanitation Options Before You BeginBather Load Chemical SafetyChemical Overview Physical Chemical HazardsFor use with any Clear Water Plan Chemical DescriptionsFor use with the chlorine Clear Water Plan For use with the bromine Clear Water PlanFor use with the Cal Clarity Bromine Generator Start Up Traditional Chemical Start Up Bromine Clear Water PlanDay One Monday Day Two WednesdayOzonator Clear Water Plan Chlorine Clear Water PlanDay One Monday Day Two WednesdayDay Two Friday Bromine Generator Clear Water PlanMaintenance Schedule Cleaning and Maintenance Removing and Reseating the PillowsSpa Cover Freeze damage is not covered by your warranty Draining Your Portable SpaWinterizing Cold Climate Draining Cleaning the Cover, Shell and Pillows Exclusive Bio-Clean Filter Cartridge Cleaning and Replacing the FilterRaising and Lowering Using the Entertainment SystemOperating the CD Player Playing a MovieUsing the Universal Remote Control Using the iPod Docking StationProgramming the Universal Remote Control Device Device ManufacturerCode Appendix Replacement PartsMjlw Power Storm JET, Directional SXW Power Storm JET, Swirley Pillows ValvesDrains WaterfallsFilters Replacement Cabinet PanelsPumps LED LightsStandard Grey 5 to Covers Standard Rust 5 toStandard Slate 5 to Description SeriesDeluxe Grey 5 to Deluxe Rust 5 toDeluxe Slate 5 to Deluxe Teal 5 toDeluxe Navy 5 to Ultimate Fitness Series Exercise Program Keeping Fit with your SpaConnecting the Exercise Equipment Cal Spas Chemicals Warranty Warranty Specifics Warranty LimitationsWarranty Exclusions LTR20081000, Rev. B LTR20081000, Rev. B Locating the product serial number