8
Operating SpaYour
Diagnostic Messages
Message | Meaning | Action Required |
|
|
|
No message | 1) Spa temperature is unknown. | 1) After pump has been running for 2 minutes tem- |
on display |
| perature will be displayed. |
| 2) Spa is in Economy or Sleep | 2) In Economy or Sleep mode, the pump may be off |
| mode. | for hours outside a filter cycle. If you wish to see the |
|
| current spa temperature, either switch to Standard |
|
| mode or turn Jets1 on for at least two minutes. |
| 3) Power has been cut off to the | 3) The control panel will be disabled until power re- |
| spa. | turns. Spa settings and time of day will be preserved |
|
| for 30 days with a battery |
|
|
|
dr | Insufficient water detected in | Check water level in spa. Refill if necessary. Make |
| heater. Spa will be shut down for | sure pumps are been primed and filter cartridges are |
| 15 minutes. | clean. Press any button to reset or wait 15 minutes |
|
| and spa will automatically reset. If message spa does |
|
| not reset, call your dealer or service organization. |
|
|
|
drY | Insufficient water detected in | Follow directions for dr message and press any button |
| heater. Spa is shut down. | to reset spa. Spa will not automatically reset when dry |
| (Displays on third occurrence of dr | or dY is displayed. |
|
| |
| message.) |
|
|
|
|
Ec | Indicates heater is in Economy | None. |
| Mode. |
|
|
|
|
Temperature unknown | After the pump has been running for two minutes, the | |
|
| temperature will be displayed. |
|
|
|
HFL | A difference in readings between | Make sure spa is filled to proper level and that pumps |
| temperature sensors has been | are primed and filter cartridges are clean. If message |
| detected indicating a possible water | does not reset, call your dealer or service organiza- |
| flow problem. | tion. |
ICE | Potential freeze condition detected. | No action required. The pumps and the blower will |
|
| automatically activate regardless of spa status. |
LF | Persistent low flow problems. | Follow action required for HL or HFL message. Heat- |
| Heater is shut down, but other spa | ing capacity of the spa will not reset automatically. |
| functions continue to run normally. | Press any button to reset. |
| Displays on the fifth occurrence of |
|
| the HL or HFL message within 24 |
|
| hours. |
|
|
|
|
OHS | Overheat protection. The spa has | DO NOT ENTER THE WATER. Remove the spa cover |
| shut down. One of the sensors | and allow water to cool. At 107°F, the spa should |
| has detected that the spa water is | automatically reset. If spa does not reset, shut off |
| 110°F. | the power to the spa and call your dealer or service |
|
| organization. |
|
|
|
2009 Genesis Portable Spa
www.calspas.com | LTR20091058, Rev. B |