Cal Spas LTR20091058 Operating SpaYour, Diagnostic Messages, Meaning, Action Required, No message

Page 10
Operating SpaYour

8

Operating SpaYour

Diagnostic Messages

Message

Meaning

Action Required

 

 

 

No message

1) Spa temperature is unknown.

1) After pump has been running for 2 minutes tem-

on display

 

perature will be displayed.

 

2) Spa is in Economy or Sleep

2) In Economy or Sleep mode, the pump may be off

 

mode.

for hours outside a filter cycle. If you wish to see the

 

 

current spa temperature, either switch to Standard

 

 

mode or turn Jets1 on for at least two minutes.

 

3) Power has been cut off to the

3) The control panel will be disabled until power re-

 

spa.

turns. Spa settings and time of day will be preserved

 

 

for 30 days with a battery back-up.

 

 

 

dr

Insufficient water detected in

Check water level in spa. Refill if necessary. Make

 

heater. Spa will be shut down for

sure pumps are been primed and filter cartridges are

 

15 minutes.

clean. Press any button to reset or wait 15 minutes

 

 

and spa will automatically reset. If message spa does

 

 

not reset, call your dealer or service organization.

 

 

 

drY

Insufficient water detected in

Follow directions for dr message and press any button

 

heater. Spa is shut down.

to reset spa. Spa will not automatically reset when dry

 

(Displays on third occurrence of dr

or dY is displayed.

 

 

 

message.)

 

 

 

 

Ec

Indicates heater is in Economy

None.

 

Mode.

 

 

 

 

--

Temperature unknown

After the pump has been running for two minutes, the

 

 

temperature will be displayed.

 

 

 

HFL

A difference in readings between

Make sure spa is filled to proper level and that pumps

 

temperature sensors has been

are primed and filter cartridges are clean. If message

 

detected indicating a possible water

does not reset, call your dealer or service organiza-

 

flow problem.

tion.

ICE

Potential freeze condition detected.

No action required. The pumps and the blower will

 

 

automatically activate regardless of spa status.

LF

Persistent low flow problems.

Follow action required for HL or HFL message. Heat-

 

Heater is shut down, but other spa

ing capacity of the spa will not reset automatically.

 

functions continue to run normally.

Press any button to reset.

 

Displays on the fifth occurrence of

 

 

the HL or HFL message within 24

 

 

hours.

 

 

 

 

OHS

Overheat protection. The spa has

DO NOT ENTER THE WATER. Remove the spa cover

 

shut down. One of the sensors

and allow water to cool. At 107°F, the spa should

 

has detected that the spa water is

automatically reset. If spa does not reset, shut off

 

110°F.

the power to the spa and call your dealer or service

 

 

organization.

 

 

 

2009 Genesis Portable Spa

www.calspas.com

LTR20091058, Rev. B

Image 10
Contents LTR20091058, Rev. B 6/15/09 Filling and Powering Up Your Portable Spa Cleaning and MaintenanceElectrical Installation Diagnostic MessagesREAD AND FOLLOW ALL INSTRUCTIONS Important Safety InstructionsThis First DANGER --Risk of accidental drowningRead First!This SAVE THESE INSTRUCTIONSAllow for Service Access Safety FirstKeep Your Spa Clean Preparing for Your New Portable SpaNewYour SpaPortable Electrical InstallationTesting the GFCI Preparing a Good FoundationVERY IMPORTANT Filling and Powering Up Your Portable SpaYour New Portable Spa Never fill your spa with soft waterOperating Your Spa Temperature AdjustmentSwitching Modes OperatingYour SpaSetting Filtration Cycles Message Diagnostic MessagesOperating SpaYour MeaningAction Required Jets LED Light OperationThe Key to Clear Water Clear Water PlanClear Water Plan Clear PlanWater Testing and Adjusting Spa WaterTesting For Balancing the Total AlkalinityUsing Bromine as a Sanitizer Using Chlorine as a SanitizerSanitation Shocking the Water Chemical SafetyIdeal Range Cleaning the Filter Basket Cleaning the FilterBather Load Starting the Spa with Fresh Water PlanClear Water Prior to each use Maintenance ScheduleEach time you refill the spa Once a weekPossible Solutions Troubleshooting Water Clarity ProblemsProblem Probable CausesDo not run the spa with the access panel removed Cleaning and MaintenanceRemoving the Access Panel Draining Your Portable SpaWinterizing Cold Climate Draining Cleaning and MaintenanceInstalling Cover Latches Freeze damage is not covered by your war- rantyVinyl and Leather Cleaner Cleaning and Replacing the FilterCleaning the Cover Periodic MaintenancePrior to Spa Start-Upand Refilling Cleaning the ShellAll-PurposeCleaner Spa Finish Cleaning Fast Sheen Spa Finish Protecting WaxDrain Replacement PartsAppendix WaterfallWarranty Performance 2009 WarrantyManufacturer Warranty Warranty Limitations and ExclusionsDisclaimers Customer ServiceLegal Remedies Cal Spas Chemicals 26 Appendix2009 Genesis Portable Spa LTR20091058, Rev. B2009 Genesis Portable Spa LTR20091058, Rev. B2009 Genesis Portable Spa Locating the product serial number