7-11. Diagnostic LED’s On Automation Interface Module PC9
LED | Status | Diagnosis |
|
|
|
1 | On | Input signal On from robot for jog advance |
|
|
|
| Off | Input signal Off from robot for no jog advance |
|
|
|
2 | On | Input signal On from robot to energize contactor |
|
|
|
| Off | Input signal Off from robot to not energize contactor |
|
|
|
3 | On | Input signal On remote program A selected |
|
|
|
| Off | Input signal Off remote program A not selected |
|
|
|
4 | On | Input signal On remote program C selected |
|
|
|
| Off | Input signal Off remote program C not selected |
|
|
|
5 | On | Input signal On from |
|
|
|
| Off | Input signal Off from |
|
|
|
6 | On | Spare 1 not assigned |
|
|
|
| Off | Spare 1 not assigned |
|
|
|
7 | On | Input signal On |
|
|
|
| Off | Input signal Off |
|
|
|
8 | On | Input signal On |
|
|
|
| Off | Input signal Off |
|
|
|
9 | On | Input signal On Remote Jog on from peripheral plug |
|
|
|
| Off | Input signal Off Remote Jog off from peripheral plug |
|
|
|
10 | On | Input signal On Remote Purge on from peripheral plug |
|
|
|
| Off | Input signal Off Remote Purge off from peripheral plug |
|
|
|
11 | On | Input signal On from robot for jog retract |
|
|
|
| Off | Input signal Off from robot for no jog retract |
|
|
|
12 | On | Input signal On from robot for purge |
|
|
|
| Off | Input signal Off from robot for no purge |
|
|
|
13 | On | Input signal On remote program B selected |
|
|
|
| Off | Input signal Off remote program B not selected |
|
|
|
14 | On | Input signal On Touch Sensor on from robot or peripheral plug |
|
|
|
| Off | Input signal Off Touch Sensor off from robot or peripheral plug |
|
|
|
15 | On | Spare 0 not assigned |
|
|
|
| Off | Spare 0 not assigned |
|
|
|
16 | On | Spare 2 not assigned |
|
|
|
| Off | Spare 2 not assigned |
|
|
|
17 | On | Input signal On |
|
|
|
| Off | Input signal Off |
|
|
|
18 | On | Input signal On |
|
|
|
| Off | Input signal Off |
|
|
|
19 | On | Input signal On Remote Retract on from peripheral plug |
|
|
|
| Off | Input signal Off Remote Retract off from peripheral plug |
|
|
|
20 | On | Input signal On Remote Water Flow on from peripheral plug |
|
|
|
| Off | Input signal Off Remote Water Flow off from peripheral plug |
|
|
|
21 | On | Input signal On from robot for no emergency stop |
|
|
|
| Off | Input signal Off from robot for emergency stop |
|
|
|
23 | On | Input signal On from relay K3 for welding power source ready and no detected errors present |
|
|
|
| Off | Input signal Off from relay K3 for welding power source not ready, detected errors are present, or unit is |
|
| in operating mode preventing the weld ready signal from being enabled |
|
|
|