4-2. Front Panel Controls (See Section 4-3)

15

14

13

1

4

12

Program

Volts

Arc Adjust

 

3

 

Wire Speed

Amps

 

11

 

 

 

 

 

 

Process

 

 

Wirefeed

 

 

Wire Type

 

 

Gas

10

 

Gas Type

 

 

Contactor

 

5

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

8

7

Setup

Adjust

 

Arc Control

9

 

 

2

. When an LED is lit, it means the related function is active.

1 Program Display

Displays the number of the active program.

2 Adjust Knob

Turn the Adjust knob to change program number, Setup, Arc Control, and weld parameters.

3 Program Push Button LED

The LED lights when the Program Push Button is active.

4 Program Push Button

Press push button (LED lights) and turn Adjust knob to select active program.

The letter C is displayed with the program number if the program has been changed from the factory settings using the optional PDA with File Management/WaveWriter software (see File Management/WaveWriter Owner’s Manual).

.The program cannot be changed through the front panel while welding.

Press and hold button to see program name. Custom programs are named using optional

PDA with File Management/WaveWriter software. Program name is shown in upper and lower displays (items 13 and 15).

5 Setup Mode Indicators

The lit LED indicates which setup mode is active. Setup mode parameters are shown in Display Windows (see Items 13 and 15).

Process LED

When this LED is lit, turn the Adjust knob to select the desired weld process. Choices include pulse welding (displayed as PULS), Accu-pulse, MIG welding (MIG), and Accu Puls/RMD [Regulated Metal Deposition (optional)].

Wire Type LED

When this LED is lit, turn the Adjust knob to select the desired wire type, wire alloy, and size. Wire type and size choices vary according to the selected weld process. Choices may include steel (displayed as STL), stainless steel (SS), metal core (MCOR), aluminum (ALUM). See Table 4-1for all wire abbreviations.

198 993

Gas Type LED

When this LED is lit, turn the Adjust knob to select the desired weld gas. Gas type choices vary according to the selected weld process.

See Table 4-1for all gas abbreviations.

6 Setup Push Button LED

The LED lights to indicate one of the setup modes is active.

7 Setup Push Button

Press button to select Process, Wire Type, Wire Diameter, or Gas Type parameters.

.In order for selections to be retained in memory, the Setup push button must be pressed six times before any other push button is pressed: once to select Process, again to select Wire Type, again to select Wire Alloy, again to select Wire Size, again to select Gas Type, and a sixth time to store selections in memory. The displays will temporarily show “PROG LOAD” to indicate the data is being stored in memory.

OM-210 540 Page 24

Page 28
Image 28
Miller Electric Auto-Axcess 450 manual Front Panel Controls See Section, Process LED, Wire Type LED, Gas Type LED