Library Operations
Diagnostics screen
The Diagnostics screen allows you to perform the following diagnostic tests on the library (see Table 7).
Note: The library must be
Table 7: Diagnostic tests
Test | Description |
Robotics Self Test | Checks for unrestricted motion of the library robotics. |
|
|
Robotics to | Calibrates the library robotics and sets it to the bottom of the |
Home Position | library with the optical sensor facing the back. |
|
|
Calibrate | Checks the position of all panels and columns, checks that the |
Cabinet | picker is aligned with the slots. |
|
|
Sequential Slot | Performs an inventory of the library, then checks each slot in the |
Test | library, sequentially, to determine whether there is free |
| movement of the tapes in and out of the slots. |
|
|
Sequential Drive | Performs an inventory of the library, then checks drives in the |
Test | library, sequentially, to determine whether it is communicating |
| properly with the drives. |
|
|
Random Test | Performs an inventory of the library, then randomly selects and |
| runs one of the tests. |
|
|
Random Slot | Performs an inventory of the library, then checks a sampling of |
Test | slots in the library, in random order, to determine whether there |
| is free movement of the tapes in and out of the slots. |
|
|
Random Slot to | Performs an inventory of the library, then checks a sampling of |
Drive Test | drives in the library, in random order, to determine whether it is |
| communicating properly with the drives and whether there is free |
| movement of the tapes into and out of the slots. |
|
|
The Sequential Slot Test, Sequential Drive Test, Random Test, Random Slot Test, and Random Slot to Drive Test can be run from
70 | ESL |