Sense Data Values

Table 22: Sense data values (Hexadecimal) (Continued)

Sense

 

 

 

Key

ASC

ASCQ

Message Name/Description

5

25

00

LOGICAL UNIT IS NOT SUPPORTED

 

 

 

Verify the logical unit field specified in the command contains a

 

 

 

legitimate logical unit number. Check cabling to logical unit.

 

 

 

 

5

26

00

INVALID FIELD IN PARAMETER LIST

 

 

 

Verify Mode Select page fields. Verify that fields comply with

 

 

 

command format described in this guide.

 

 

 

 

5

26

02

PARAMETER VALUE INVALID

 

 

 

Verify Mode Select page fields. Verify that fields comply with

 

 

 

command format described in this guide.

 

 

 

This response is also returned for commands issued to the diagnostic

 

 

 

interface of the library if an invalid parameter is sent.

 

 

 

 

6

28

01

IMPORT OR EXPORT ELEMENT ACCESSED

 

 

 

Load port door has been closed.

 

 

 

 

6

29

00

POWER-ON, RESET OR BUS DEVICE RESET OCCURRED

 

 

 

Informational message. If power on occurs, the host user should

 

 

 

assume the inventory may have changed, and should ask the library

 

 

 

for that information again.

 

 

 

 

6

29

01

POWER-ON RESET OCCURRED.

 

 

 

Informational message. If power on occurs, the host user should

 

 

 

assume the inventory may have changed, and should ask the library

 

 

 

for that information again.

 

 

 

 

6

29

02

BUS RESET OCCURRED.

 

 

 

Informational message. If power on occurs, the host user should

 

 

 

assume the inventory may have changed, and should ask the library

 

 

 

for that information again.

 

 

 

 

6

29

03

BUS DEVICE RESET OCCURRED

 

 

 

Informational message. If power on occurs, the host user should

 

 

 

assume the inventory may have changed, and should ask the library

 

 

 

for that information again.