Sense Data Values
Table 22: Sense data values (Hexadecimal) (Continued)
Sense |
|
|
|
Key | ASC | ASCQ | Message Name/Description |
5 | 25 | 00 | LOGICAL UNIT IS NOT SUPPORTED |
|
|
| Verify the logical unit field specified in the command contains a |
|
|
| legitimate logical unit number. Check cabling to logical unit. |
|
|
|
|
5 | 26 | 00 | INVALID FIELD IN PARAMETER LIST |
|
|
| Verify Mode Select page fields. Verify that fields comply with |
|
|
| command format described in this guide. |
|
|
|
|
5 | 26 | 02 | PARAMETER VALUE INVALID |
|
|
| Verify Mode Select page fields. Verify that fields comply with |
|
|
| command format described in this guide. |
|
|
| This response is also returned for commands issued to the diagnostic |
|
|
| interface of the library if an invalid parameter is sent. |
|
|
|
|
6 | 28 | 01 | IMPORT OR EXPORT ELEMENT ACCESSED |
|
|
| Load port door has been closed. |
|
|
|
|
6 | 29 | 00 |
|
|
|
| Informational message. If power on occurs, the host user should |
|
|
| assume the inventory may have changed, and should ask the library |
|
|
| for that information again. |
|
|
|
|
6 | 29 | 01 |
|
|
|
| Informational message. If power on occurs, the host user should |
|
|
| assume the inventory may have changed, and should ask the library |
|
|
| for that information again. |
|
|
|
|
6 | 29 | 02 | BUS RESET OCCURRED. |
|
|
| Informational message. If power on occurs, the host user should |
|
|
| assume the inventory may have changed, and should ask the library |
|
|
| for that information again. |
|
|
|
|
6 | 29 | 03 | BUS DEVICE RESET OCCURRED |
|
|
| Informational message. If power on occurs, the host user should |
|
|
| assume the inventory may have changed, and should ask the library |
|
|
| for that information again. |
|
|
|
|
ESL | 131 |