Sense Data Values
Table 22: Sense data values (Hexadecimal) (Continued)
Sense |
|
|
|
Key | ASC | ASCQ | Message Name/Description |
5 | 87 | F0 | DEPTH INVALID COMMAND |
|
|
| Depth hardware commanded to position out of system mechanical |
|
|
| limits. Issue a Rezero Unit command. If the problem persists, calibrate |
|
|
| the library. |
|
|
|
|
4 | 88 | 00 | WARNING SAFE TEMPERATURE EXCEEDED |
|
|
| This is only a warning that the temperature in the library exceeds the |
|
|
| normal operational temperature (96.8oF). |
4 | 88 | 01 | MAXIMUM TEMPERATURE EXCEEDED |
|
|
| The robot in the cabinet that has overheated turns off and remains off |
|
|
| until the temperature returns to an acceptable level |
4 | 89 | VISION HARDWARE FAILURE | |
|
|
| Vision internal failure. Call Technical Support. |
|
|
|
|
5 | 8A | 02 | UNCALIBRATED POSITION |
|
|
| System requires calibration. |
|
|
|
|
6 | 8A | 02 | CALIBRATION FAILURE |
|
|
| Check slots, cartridges, all internal elements. |
|
|
|
|
4 | 8B | See | CLM HARDWARE FAILURE |
|
| Table 23 | CLM failure. Call Technical Support. |
|
|
| |
|
|
|
|
5 | 8B | E0 | CLM INVALID START CONDITION |
|
|
| CLM hardware condition is unknown. Issue a Rezero Unit command. |
|
|
|
|
5 | 8B | F0 | CLM INVALID COMMAND |
|
|
| CLM hardware commanded to position out of system mechanical |
|
|
| limits. Issue a Rezero Unit command. If the problem persists, calibrate |
|
|
| the library. |
|
|
|
|
B | 8B | C0 | TRANSPORT FULL |
|
|
| The CLM contains a cartridge. Issue a command to retrieve the |
|
|
| cartridge from the CLM and place it in either a bin or a tape drive. |
|
|
|
|
138 | ESL |