Sense Data Values

Table 22: Sense data values (Hexadecimal)

Sense

 

 

 

Key

ASC

ASCQ

Message Name/Description

0

00

00

NO ADDITIONAL SENSE INFORMATION

 

 

 

No recovery necessary.

 

 

 

 

2

04

00

LU IS NOT READY, CAUSE NOT REPORTABLE

 

 

 

Internal error. Retry command.

 

 

 

 

2

04

01

LOGICAL UNIT IN PROCESS OF BECOMING READY

 

 

 

Wait for library unit to complete initialization.

 

 

 

 

2

04

02

LOGICAL UNIT INIT REQUIRED

 

 

 

Element status or calibration unknown. Perform “Initialize Element

 

 

 

Status” command (SCSI) or “Initialize Inventory” command (DIAG).

 

 

 

 

2

04

03

LU IS NOT READY, MANUAL INTERVENTION REQ’D

 

 

 

Initialization failed. Determine failure type by checking any previous

 

 

 

error code returned to host. Reinitialize element status through

 

 

 

backup package or command line interface.

 

 

 

 

5

04

07

DRIVE FW UPDATE IN PROGRESS

 

 

 

The drive can not perform indicated request because it is in the

 

 

 

process of updating it’s firmware.

 

 

 

 

B

08

00

LOGICAL UNIT COMMUNICATION FAILURE

 

 

 

Check cables. Ensure library unit is powered on. Retry command.

 

 

 

 

B

08

01

LIBRARY COMMUNICATION TIME-OUT

 

 

 

Internal communications not responding. Retry command.

 

 

 

 

5

1A

00

PARAMETER LIST LENGTH ERROR

 

 

 

Invalid parameter list length field specified by command.

 

 

 

 

5

20

00

INVALID COMMAND OPERATION CODE

 

 

 

Verify the host command format.

 

 

 

 

5

21

01

INVALID ELEMENT ADDRESS

 

 

 

Check Mode Sense data for correct element addresses.

 

 

 

 

5

24

00

INVALID FIELD IN COMMAND DATA BLOCK

 

 

 

Ensure all reserve fields are set to zero.