Library Characteristics

Environmental specifications

Table 21 provides various library environmental specifications.

Table 21: Environmental specifications

 

Power Environment

Electrical inputs

Voltage

200 VAC to 240 VAC

 

Rated Frequency

50/60 Hz

 

Rated Current

8A

 

Power consumption

VA max 1600W

 

Electrical connection to

IEC 320 C19 male connector

 

power

inside back door

 

 

 

 

Climatic Environment

Temperature

Dry Bulb

15oC to 32oC (59oF to 90oF)

(operating)

Wet bulb

25oC (77oF) maximum

 

Thermal transition

11oC per hour

Temperature

Dry bulb

-40oC to 66oC (-40oF to 151oF)

(shipping and

Wet bulb

46oC (115oF) maximum

storage)

Thermal transition

30oC (54oF) per hour

 

Relative humidity

Operating

20% to 80%, non-condensing

 

Shipping and storage

5% to 95%, non-condensing

 

 

 

Altitude

Operating

Sea Level to 10,000 ft.

 

 

(3,048 m)

 

Shipping and storage

Sea Level to 12,000 ft.

 

 

(3,657 m)

 

 

 

Heat dissipation

Operating

5500 BTU/hr (1400 KCal/hr or

 

 

1600 watts)

Direct ESD

Contact discharge

@ 2.0, 4.0, 6.0, 8.0 kV to all

 

 

external metal panels and doors

 

Air discharge

@ 2.0, 4.0, 6.0, 8.0, 10.0,

 

 

12.0, 15.0 kV to the front GUI

 

 

display

 

 

 

Indirect ESD

Contact discharge

@ 2.0, 4.0, 6.0, 8.0 kV to the

 

 

VCP