Maintenance and Troubleshooting
Start-up problems
Table 8 describes corrective actions for problems which occur during
Table 8:
Problem | Corrective Action |
The library does not power on. | Verify that: |
| ■ The power cord is connected to a |
| grounded electrical outlet. |
| ■ The power distribution unit’s two |
| breaker switches are on (left rear |
| corner of cabinet). |
| ■ The power supply switches are on. |
| ■ The power switch behind the service |
| tray is on. |
|
|
The library or tape drives are not | ■ Verify cable connections and |
detected by the Interface Manager or | termination. |
Command View ESL software. | ■ Verify the cabling. |
| ■ Verify that the drives and library are |
| powered on and ready. |
| ■ Ensure that the interface controllers |
| are powered on and ready. |
|
|
During initialization, the library reports | ■ Determine the failure type by |
“not ready.” | checking any previous error codes |
| returned to the host computer, or by |
| getting a library support ticket. |
| ■ Correct the cause of the error. |
|
|
One or more tape drives fail to spin up | ■ Verify cable connections and |
during | termination. |
| ■ Make sure the OCP does not show |
| the drive power as off. |
| ■ Check that the power supplies are |
| switched on for that level (clusters |
| 0 - 5). |
| ■ Check that the cluster controller is |
| properly cabled and ready. |
|
|
76 | ESL |