Sense Data Values
Table 22: Sense data values (Hexadecimal) (Continued)
Sense |
|
|
|
Key | ASC | ASCQ | Message Name/Description |
5 | 80 | 22 | ELEMENT CONTENTS UNKNOWN |
|
|
| The contents of an element address are unknown. Issue a Read |
|
|
| Element Status for the element address. If contents are still unknown |
|
|
| issue an Initialize Element Status command. |
|
|
|
|
4 | 80 | 23 | BAR CODE SCANNER FAILURE |
|
|
| Bar code scanner has failed. Reinitialize element status. |
|
|
|
|
4 | 81 | See | PICKER HARDWARE FAILURE |
|
| Table 23 | Picker hardware failure. Call Technical Support. |
|
|
| |
|
|
|
|
5 | 81 | C0 | TRANSPORT FULL |
|
|
| The picker contains a cartridge. Issue a command to retrieve the |
|
|
| cartridge from the picker and place it in either a bin or a tape drive. |
|
|
|
|
5 | 81 | E0 | PICKER INVALID START CONDITION |
|
|
| Picker hardware condition is unknown. Issue a Rezero Unit |
|
|
| command. |
|
|
|
|
5 | 81 | F0 | PICKER INVALID COMMAND |
|
|
| Picker hardware commanded to position out of system mechanical |
|
|
| limits. Issue a Rezero Unit command. |
|
|
|
|
4 | 82 | See | ROTARY HARDWARE FAILURE |
|
| Table 23 | Rotary hardware failure. Call Technical Support. |
|
|
| |
|
|
|
|
5 | 82 | E0 | ROTARY INVALID START CONDITION |
|
|
| Rotary hardware condition is unknown. Issue a Rezero Unit |
|
|
| command. |
|
|
|
|
5 | 82 | F0 | ROTARY INVALID COMMAND |
|
|
| Rotary axis was commanded to a position out of its legal range. This |
|
|
| is an internal code failure. |
|
|
|
|
4 | 83 | See | EXTENSION HARDWARE FAILURE |
|
| Table 23 | Extension hardware failure. Call Technical Support. |
|
|
| |
|
|
|
|
136 | ESL |