Maintenance and Troubleshooting

Operating problems

Table 11 describes the corrective action for problems that occur during library operation.

Table 11: Problems during library operation

Problem

 

Corrective Action

The host computer

Verify that the host computer has been added to the

cannot communicate

 

secure manager via the Command View ESL

with the library.

 

software, and has been given access to library

 

components.

 

 

 

Verify cable connections and termination.

 

Verify that the FC port link LEDs show good status.

 

Restart the host and the library.

 

If the host and library still are not communicating,

 

 

verify that there is not a zoning issue.

 

 

 

A tape cartridge

This indicates that the picker could not sense a tape

(medium) is reported

 

cartridge in a particular storage bin, even though the

not present.

 

inventory reports that it is present.

 

Verify that the designated cartridge is present and

 

 

 

properly seated. (For a tape drive, make sure the

 

 

cartridge is completely unloaded.) Then, retry the

 

 

command.

 

Perform an inventory.

 

If the error persists, contact a field service engineer.