Maintenance and Troubleshooting
Operating problems
Table 11 describes the corrective action for problems that occur during library operation.
Table 11: Problems during library operation
Problem |
| Corrective Action |
The host computer | ■ | Verify that the host computer has been added to the |
cannot communicate |
| secure manager via the Command View ESL |
with the library. |
| software, and has been given access to library |
| components. | |
|
| |
| ■ Verify cable connections and termination. | |
| ■ Verify that the FC port link LEDs show good status. | |
| ■ Restart the host and the library. | |
| ■ If the host and library still are not communicating, | |
|
| verify that there is not a zoning issue. |
|
|
|
A tape cartridge | ■ | This indicates that the picker could not sense a tape |
(medium) is reported |
| cartridge in a particular storage bin, even though the |
not present. |
| inventory reports that it is present. |
| Verify that the designated cartridge is present and | |
| ■ | |
|
| properly seated. (For a tape drive, make sure the |
|
| cartridge is completely unloaded.) Then, retry the |
|
| command. |
| ■ | Perform an inventory. |
| ■ If the error persists, contact a field service engineer. | |
|
|
|
80 | ESL |