Sense Data Values

Table 23: Hardware failure ASCQ values (Continued)

ASCQ

Description

90-9FFORCE ERROR

While pushing a cartridge into a bin or drive, the extension axis never made contact with any object.

A0-AFSENSOR FAILURE

A sensor transition did not occur as expected or an extra transition occurred during calibration, inventory or pick/place. Retry the command. If the failure recurs, contact Technical Support.

B0-BFELECTRONICS NOT PRESENT

Electronics necessary for hardware to function is not present. Install necessary hardware.