Sense Data Values
Table 22: Sense data values (Hexadecimal) (Continued)
Sense |
|
|
|
Key | ASC | ASCQ | Message Name/Description |
6 | 80 | 07 | SYSTEM STOP BUTTON WAS PRESSED |
|
|
| The STOP button on the control panel was pressed. Press the STOP |
|
|
| button. Retry command. |
|
|
|
|
6 | 80 | 08 | LOGICAL UNIT TURNED |
|
|
| Through the menu options, bring the library |
|
|
|
|
2 | 80 | 09 | LOGICAL UNIT IS TURNED |
|
|
| Through the menu options, bring the library |
|
|
|
|
6 | 80 | 09 | LOGICAL UNIT TAKEN OFFLINE |
|
|
| Library was taken |
|
|
| GUI. |
|
|
|
|
B | 80 | 10 | LOAD RETRY FAILED |
|
|
| Library was unable to successfully load and thread the drive, even |
|
|
| after retries. Check drive alignment. If the problem continues, drive |
|
|
| may need servicing. |
|
|
|
|
4 | 80 | 0A | CONFIGURATION SETTINGS CORRUPTED |
|
|
| Reconfigure the library. If problem persists, call Technical Support. |
|
|
|
|
B | 80 | 0B | COMMAND ABORTED BY USER |
|
|
| Informational message. No action is necessary. |
|
|
|
|
B | 80 | 0D | CARTRIDGE PARTIALLY GRIPPED |
|
|
| Issue a Move Medium command using your application software to |
|
|
| move the cartridge from the transfer element to an empty storage |
|
|
| element. |
|
|
|
|
6 | 80 | 0E | DATA TRANSFER CHANGED |
|
|
| A drive has been inserted/removed into the system. Use “Read |
|
|
| Element Status” to determine status of drives. |
|
|
|
|
4 | 80 | 0F | LOW POWER ERROR |
|
|
| Check power connections. |
|
|
|
|
4 | 80 | 11 | MOTOR POWER FAILURE |
|
|
| Indicates motor powered off for a reason not otherwise reported. |
|
|
|
|
ESL | 135 |