Sense Data Values

Table 22: Sense data values (Hexadecimal) (Continued)

Sense

 

 

 

Key

ASC

ASCQ

Message Name/Description

6

80

07

SYSTEM STOP BUTTON WAS PRESSED

 

 

 

The STOP button on the control panel was pressed. Press the STOP

 

 

 

button. Retry command.

 

 

 

 

6

80

08

LOGICAL UNIT TURNED ON-LINE

 

 

 

Through the menu options, bring the library on-line.

 

 

 

 

2

80

09

LOGICAL UNIT IS TURNED OFF-LINE

 

 

 

Through the menu options, bring the library on-line.

 

 

 

 

6

80

09

LOGICAL UNIT TAKEN OFFLINE

 

 

 

Library was taken off-line through the remote web management or

 

 

 

GUI.

 

 

 

 

B

80

10

LOAD RETRY FAILED

 

 

 

Library was unable to successfully load and thread the drive, even

 

 

 

after retries. Check drive alignment. If the problem continues, drive

 

 

 

may need servicing.

 

 

 

 

4

80

0A

CONFIGURATION SETTINGS CORRUPTED

 

 

 

Reconfigure the library. If problem persists, call Technical Support.

 

 

 

 

B

80

0B

COMMAND ABORTED BY USER

 

 

 

Informational message. No action is necessary.

 

 

 

 

B

80

0D

CARTRIDGE PARTIALLY GRIPPED

 

 

 

Issue a Move Medium command using your application software to

 

 

 

move the cartridge from the transfer element to an empty storage

 

 

 

element.

 

 

 

 

6

80

0E

DATA TRANSFER CHANGED

 

 

 

A drive has been inserted/removed into the system. Use “Read

 

 

 

Element Status” to determine status of drives.

 

 

 

 

4

80

0F

LOW POWER ERROR

 

 

 

Check power connections.

 

 

 

 

4

80

11

MOTOR POWER FAILURE

 

 

 

Indicates motor powered off for a reason not otherwise reported.