OPERATION
Moving Machine By Hand
Bypass Valves
Bypass valves are used to release the system so the machine may be moved by hand when not running.
IMPORTANT INFORMATION Tighten the valve moderately.
Do not overtighten the valve when closing. That can damage the valve seat.
Hydro Pumps
Pump release valves are located at the front and rear of the pump. Tilt the seat forward and remove the fan cover to gain access to the pump.
Use a 5/8" wrench or socket and ratchet. Turn the pump release valve ½ turn. Reverse the procedure to reset the pump.
Remove fan cover to access release valves
WARNING!
No adjustments or maintenance should be carried out unless:
•the engine stopped
•the ignition key removed
•the parking brake activated
37