JBL Professional VT4881ADP-AN, VT4887ADP Setting up a Simple Isolated Ethernet Network Using Dhcp

Page 27

QUICK-START -- CONNECTING PC TO A JBL HiQNet DEVICE FOR THE FIRST TIME:

If this your first experience connecting a control computer running System Architect to a HiQnet-compliant JBL product, then this initial test configuration will be useful. It will greatly help to resolve simple networking issues before you connect to multiple devices or connect to a larger network:

Step 1) Connect one networked loudspeaker to an unmanaged 100BaseT network switch with a standard CAT5 cable. Don’t apply AC power to the loudspeaker just yet.

Step 2) Connect the control computer to the Ethernet switch with a standard CAT5 cable.

Setting up a Simple Isolated Ethernet Network Using DHCP

In this configuration DHCP will automatically assign an IP address to the device on the network and your computer.

Step 1) Open Network Connections on your computer and confirm that DHCP is Enabled. To do this click Start, point to Settings, click Control Panel, and then double-click Network Connections. When your Network Connections Window opens, double click on the Local Area Network icon. A Local Area Connections Status window will open. Click on the Properties button and the Local Area Connection Properties window open. Next scroll through the items window, select the Internet Protocol (TCP/IP) item and click on the Properties button. The Internet Protocol (TCP/IP) Properties window will open. Select the “Obtain an IP address automatically” option. Click OK through all your open network windows to close them.

Step 2) Apply power to your JBL DrivePack and wait for it to boot up. With DHCP enabled, the DrivePack and your computer should both automatically negotiate an IP Address.

Step 3) Launch System Architect. The DrivePack system should appear in the Venue View within a few minutes.

Step 4) If nothing comes up, you should first check that your System Architect™ application has the ‘Network Active when the application starts’ and ‘Auto Populate venue view with detected devices’ boxes checked; these are found in the Tools menu under Options/General Network Information.

Step 5) If Auto Populate is checked and the network is active (look at the network status icon located at the bottom left corner of the Venue View window) and the devices are still not showing in the Venue View, select the Network Wizard in the Tools menu and change the IP address of the devices so they can be on the same network as your computer.

Set up with a Static IP address

Step 1) Go back through Step 1 above, except select “Use the following IP Address:’ option.

Step 2) Change the TCP/IP address of the control computer to 169.254.1.y and change the subnet mask set to 255.255.0.0.

Note: The placeholder “y” in the last segment of the IP address represents a number anywhere in the range of 1 to 254. The only requirement in your number selection is that no two devices on the same network can share the same IP address. Depending upon PC operating system configuration a reboot may be needed now.

Step 3) Avoid connecting the switch to any other Ethernet equipment other than the PC and the loudspeaker just yet.You’re creating a network with only two devices -- the PC and the loudspeaker.This is useful for a first test as it avoids any additional networking configuration issues.

JBL Professional 27

Image 27
Contents Product User’s Guide Vertec User’s Guide Table of Contents Safety Instructions CSA Compliance Notice JBL Drivepack Declaration of Conformity Safety and EMC Compliance SpecificationsBefore YOU Begin 1x18 subwoofer system Vertec DP Series Compact Powered SystemsVertec DP SERIES, Compact Powered Systems Specifications 2408H High Frequency Compression Driver Vertec DP Series TransducersPainting JBL Vertec DP Series System Products Enclosure Care and MaintenanceRigging and Suspension Safety PrecautionsAttachment to Structures Rigging Hardware Inspection & MaintenanceAre You New to Rigging? General Hardware InformationSafe Rigging Industry ResourcesDrivePack Signal-Processing & Amplification Unit JBL Drivepack TechnologyIntroduction to JBL DrivePack Integrated Audio System Power Connector Coding User-Fabricated AC Cable and Connector InformationDP1 AC Power Ratings DP2 AC Power RatingsInput Module Controls, Indicators and Connectors AC Power ModuleDpip Standard Input Module Ready Enable ALT Preset buttonIndicators Enable ALT Preset Thermal ProtectionMAC Address Window Network 100MB LinkAudio Audio OUT12a & 12b Network 100MB Link 11a & 11b CobraNet10a & 10b CobraNet Primary and Secondary Network Connectors Protective Jacket Installation Protective Jackets for Input and AC Power ModulesJBL Professional AS-SHIPPED Ethernet Configuration System Architect SoftwareIntroduction Setting up a Simple Isolated Ethernet Network Using Dhcp Working with a Network of Multiple JBL Devices Network Setup with DhcpDisable DHCP/AUTO Hiqnet Address in System Architect Vertec User’s Guide Glossary of Terms Appendix a Configuring Cobranet Repeater Networks Switched NetworksPriority Primary and Secondary Network Ports DualinkAppendix B Setting Windows to the Standard Font Size JBL Professional Vertec User’s Guide Exclusion of Certain Damages JBL Limited WarrantyWEB Links JBL Contact InformationJBL Professional VTDP-C Prod Guide