JBL Professional VT4881ADP, VT4887ADP-CN, VT4887ADP-AN System Architect Software, Introduction

Page 26

SECTION 8 : SYSTEM ARCHITECT SOFTWARE

The VERTEC DP Series has optional advanced network control capabilities with the DPAN or DPCN input modules. VERTEC DP Series loudspeaker systems so equipped utilize Harman Professional’s HiQnet™ protocol to enable a complete configuration, control, and monitoring solution. HiQnet protocol provides remote access to loudspeaker preset files in the JBL DrivePack® input modules making system setup easy yet powerful, via the DrivePack Software Device Control Panel with its intuitive, user-friendly graphical interface. HiQnet System Architect™ provides complete software control of not only your JBL DrivePack- equipped loudspeakers, but also other HiQnet-compatible audio components within the total system.

It is recommended to visit www.harman.com for the most up to date version of HiQnet System Architect.

QUICK-START CONFIGURATION GUIDE

For JBL DrivePack-equipped loudspeaker Systems using System Architect software

INTRODUCTION:

This guide applies to all JBL loudspeaker models powered by DrivePack DP1, DP2 or DP3 amplifier assemblies which incorporate DPAN or DPCN input modules.

Each loudspeaker must be connected to a 100BaseT Ethernet switch using a standard CAT-5 cable.The control computer which will run System Architect must also be connected by a 100BaseT connection to a switch on the same physical network.

If managed Ethernet switches are a part of the network, additional knowledge of TCP/IP protocols and Ethernet-switch manufacturer-specific configurations may be required.This is beyond the scope of this document. It is assumed that unmanaged switches are used in the networking examples discussed below.

Special requirements exist for CobraNet™ - compliant products using the DPCN input module.This is addressed in Appendix A.

A Glossary of networking terminology used is provided at the end of this document.

AS-SHIPPED ETHERNET CONFIGURATION:

Each loudspeaker product is shipped from the JBL factory with the following configuration:

-DHCP is enabled. (See glossary for details)

-Auto IP address negotiation is enabled (See glossary for details)

-Auto HiQnet device setting is enabled. (See glossary for details)

-The default IP address for all products shipped is 169.254.127.1 with subnet mask 255.255.0.0

QUICK-START: CONFIGURING YOUR PC WITH SYSTEM ARCHITECT™ SOFTWARE:

1)Install System Architect software on the Microsoft Windows 2000 or XP-equipped computer that will control/monitor the HiQnet™ - compliant products.

2)Note that System Architect will only display graphics correctly when the Windows PC display is set to standard, small font size. If Windows is set to “large” fonts, then the displays within System Architect may become unreadable.To correct this problem change Windows to the standard font size. (See Appendix B for details)

3)Note that System Architect will only display graphics correctly when the Windows PC. Regional and Language settings are set to standard US English language. If Windows is set to any language other than

US English, objects in custom control panels will not display or function properly. To correct this problem change Windows to the standard font size. (See Appendix C for details)

4)If you are using a CobraNet™ - compatible product see Appendix A for special instructions now before proceeding further.

26 VERTEC User’s Guide

Image 26
Contents Product User’s Guide Vertec User’s Guide Table of Contents Safety Instructions CSA Compliance Notice Safety and EMC Compliance Specifications JBL Drivepack Declaration of ConformityBefore YOU Begin Vertec DP Series Compact Powered Systems 1x18 subwoofer systemVertec DP SERIES, Compact Powered Systems Specifications Vertec DP Series Transducers 2408H High Frequency Compression DriverEnclosure Care and Maintenance Painting JBL Vertec DP Series System ProductsSafety Precautions Rigging and SuspensionGeneral Hardware Information Rigging Hardware Inspection & MaintenanceAre You New to Rigging? Attachment to StructuresIndustry Resources Safe RiggingIntroduction to JBL DrivePack Integrated Audio System DrivePack Signal-Processing & Amplification UnitJBL Drivepack Technology User-Fabricated AC Cable and Connector Information Power Connector CodingDP2 AC Power Ratings DP1 AC Power RatingsAC Power Module Input Module Controls, Indicators and ConnectorsDpip Standard Input Module Thermal Protection Enable ALT Preset buttonIndicators Enable ALT Preset ReadyAudio OUT Network 100MB LinkAudio MAC Address Window11a & 11b CobraNet 12a & 12b Network 100MB Link10a & 10b CobraNet Primary and Secondary Network Connectors Protective Jackets for Input and AC Power Modules Protective Jacket InstallationJBL Professional Introduction AS-SHIPPED Ethernet ConfigurationSystem Architect Software Setting up a Simple Isolated Ethernet Network Using Dhcp Network Setup with Dhcp Working with a Network of Multiple JBL DevicesDisable DHCP/AUTO Hiqnet Address in System Architect Vertec User’s Guide Glossary of Terms Appendix a Configuring Cobranet Primary and Secondary Network Ports Dualink Switched NetworksPriority Repeater NetworksAppendix B Setting Windows to the Standard Font Size JBL Professional Vertec User’s Guide JBL Limited Warranty Exclusion of Certain DamagesJBL Contact Information WEB LinksJBL Professional VTDP-C Prod Guide