1. Manuals
  2. Brands
  3. Home Audio
  4. Soundbar/SoundTower
  5. Samsung
  6. Home Audio
  7. Soundbar/SoundTower

Samsung SSA-M1000 SSA-M1000/EXP system management, 80_ system management

1 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 216
Download on canonical page 216 pages, 28.71 Mb

system management

Function Name

Descriptions

 

 

Anti-passback

Antipassback limits door access only when entering and exiting matches if a door is installed with two separate

readers both for entering and exiting respectively. In general, this function is used for preventing entering a door by

 

following the previous authorization.

 

 

Door Open Alarm Time

You can set the delay time until the product triggers the door open alarm if the door stays open after the Door Relay

time. This function requires Door Contact Sensors installed.

 

 

 

Voice mode

You can set to play recorded voice guide.

 

 

Voice Mode Time

You can set time schedule for voice mode, which will play recorded voice guide only within the specified time table.

Schedule

 

Duress Mode

Duress mode requires the Duress Mode Password for enabling this function. Duress mode is a special feature that

outputs a special tacit alarm signal when it is forced to open the restricted area, by entering 2-digit code before

 

authorizing. The door opens as normally but the program generates duress event which will trigger the alert.

 

 

Duress Mode Password

The 2-digit password to trigger the Duress mode.

 

 

Arm/Disarm

Alarm controllers of other manufacturers can be connected through the access controller’s output if required. At the

moment, if armed with the ARM code and ARM card, it can be configured to make all access controllers of doors to

 

deny any access requests.

Arm/Disarm Input

If you intend to use the Arm function, you can set the Arm function via a specific input point instead of using the card.

Enable

 

Arm Code

This is a two-digit code required to set the arm function.

 

 

Disarm Code

This is a two-digit code required to release the arm function.

 

 

Two Men Mode Enable

Enable this when two men operation mode (for administrator and visitor) is required. With the two men operation

mode activated, the door will be opened if both administrator and visitor card issued in card holder management are

 

entered in a row.

 

 

JDuress mode and Arm/Disarm will require keypad readers (SSA-R2000, SSA-R2001, etc.) if used with the SSA- P102 and 400 series products.

14.Move to the [Controller Option] tab.

80_ system management
MENU

Models

Contents