BEA LO-21P manuals
Power Tools > Work Light
When we buy new device such as BEA LO-21P we often through away most of the documentation but the warranty.
Very often issues with BEA LO-21P begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Work Light BEA LO-21P is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Work Light on our side using links below.
BEA LO-21P Technical Specifications
13 pages 919.01 Kb
USERS GUIDE LO-21P LOCK OUT RELAY 2 STANDARD WIRING BODYGUARD1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 Contacts to open at desired point of inhibiting Stall SuperScan (Swing Side) OPERATOR LO-21PNOTE: Bodyguard MUST be programmed to a Relay Output value of 2. Default is 1. 3 LO-21PBODYGUARD1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 OPERATORContacts to open at desired point of inhibiting Stall SuperScan (Swing Side) NOTE: Bodyguard MUST be programmed to a Relay Output value of 2. Default is 1. 4 LO-21PBODYGUARD NOTE: Bodyguard MUST be programmed to a Relay Output value of 2. Default is 1. BODYGUARDSIZE: BLACK / WHITE VIOLET (See Note #2)(See Note #2)Wire nut DISCONNECT CABLE SUPERSCAN QUICK EAGLELEFT APPROACH SIDE LEFT SAFETY SIDE RIGHT SAFETY SIDE RIGHT APPROACH SIDEBLUE GRAY WHITE RED/WHITE 115 VAC24 V POWER 2 COM 3 N.O. 4 N.C. 5 DATA - 6 DATA + 7 DK-1275.5079.08 20061129 Page 8 of 13 5 N/C 4 N/O 3 COM 2 PWR 1 PWR SHEET:SCALE: 11 SAFETY 12 COMMON 13 ACTIVATION 16 STALL INPUT 15 STALL INPUT 18 STALL INPUT 17 STALL INPUT6 JUNE 2003 ON APPROACH SIDE PARALLAX II SYSTEM Q-DISCONNECT TITLE: BESAM 300/400 (ETIK2) WITH LO-21PNTSCAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: B.E.A., Inc.PH: (412) 249-4100 FAX: (412) 249-4101 8 A 100 Enterprise Drive Pittsburgh, PA 15275 DATE: www.beasensors.com 1 OF 1 CONTROL BESAM ETIK LO-21PHS LS HD 10 COMMONMotor Voltage (See Note #6) NOTE: 1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE APPROACH SIDE SUPERSCAN'S 2 WHITE WIRES. INSTALL THE BLUE WIRE INTO PIN 6. 2.) ON SAFETY SIDE SUPERSCANS MOVE BROWN WIRE FROM PIN 5 TO PIN 4. 3.) B-SWITCH SHOULD CLOSE AT APPROX. 65-70 DEGREES. 4.) INSTALL A JUMPER BETWEEN PINS 17&18 5.) THE BODYGUARD RELAY OUTPUT FUNCTION MUST BE CHANGED TO #2. 6.) RH MOTOR SHOWN, REVERSE LO-21P RED AND BLACK WIRES FOR LH MOTOR.DISCONNECT CABLE BROWN ORANGE (See Note #1) (See Note #1) (See Note #5)(See Note #4) (See Note #3) GREEN YELLOW BODYGUARDSIZE: YELLOW BLACK / WHITE (See Note #1)(See Note #2)(See Note #2)(See Note #1) (See Note #5)DISCONNECT CABLE SUPERSCAN QUICK EAGLELEFT APPROACH SIDE LEFT SAFETY SIDE RIGHT SAFETY SIDE RIGHT APPROACH SIDEBLUE WHITE RED/WHITE 115 VAC24 V POWER 2 COM 3 N.O. 4 N.C. 5 DATA - 6 DATA + 7 DK-1275.5079.08 20061129 Page 9 of 13 5 N/C 4 N/O 3 COM 2 PWR 1 PWR SHEET:SCALE: 11 SAFETY 12 COMMON 13 ACTIVATION 16 STALL INPUT 15 STALL INPUT 18 STALL INPUT 17 STALL INPUT80.0186 6 JUNE 2003 ON SAFETY SIDE PARALLAX II SYSTEM Q-DISCONNECT TITLE: BESAM 300/400 (ETIK2) WITH LO-21PNTSCAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: B.E.A., Inc.PH: (412) 249-4100 FAX: (412) 249-4101 9 A 100 Enterprise Drive Pittsburgh, PA 15275 DATE: www.beasensors.com 1 OF 1 Tech Support GDM B LO-21PBESAM ETIK CONTROLHS LS HD 10 COMMONMotor Voltage (See Note #6)RED + BLACK -- BROWN ORANGE NOTE: 1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE APPROACH SIDE SUPERSCAN'S WHITE WIRE. INSTALL THE YELLOW WIRE INTO PIN 6. 2.) ON SAFETY SIDE SUPERSCAN MOVE GREEN WIRE FROM PIN 5 TO PIN 4. 3.) B-SWITCH SHOULD CLOSE AT APPROX. 65-75 DEGREES. 4.) INSTALL A JUMPER BETWEEN PINS 17&18 5.) THE BODYGUARD RELAY OUTPUT FUNCTION MUST BE CHANGED TO #2. 6.) RH MOTOR SHOWN, REVERSE LO-21P RED AND BLACK WIRES FOR LH MOTOR.(See Note #4) (See Note #3) YELLOW VIOLET GRAY GREEN BODYGUARDSIZE: (See Note #1) (See Note #3) EAGLEDISCONNECT CABLE SUPERSCAN QUICK LEFT APPROACH SIDE LEFT SAFETY SIDE RIGHT SAFETY SIDE RIGHT APPROACH SIDE LO-21PPOWER 1 115 VAC24 V POWER 2 COM 3 N.O. 4 N.C. 5 DATA - 6 DATA + 7 DK-1275.5079.08 20061129 Page 10 of 13 5 N/C 4 N/O 3 COM 2 PWR 1 PWR SHEET:SCALE: SUPERSCAN QUICK CONTROL STANLEY MP8 COMMON 7 SAFETY/STALL 6 AUX INPUT 5 12 VAC 4 12 VAC 3 SENSOR OP 2 OPERATE 1 COMMON80.0187 6 JUNE 2003 ON APPROACH SIDE PARALLAX II SYSTEM Q-DISCONNECT TITLE: STANLEY MP CONTROL WITH LO-21PCAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: DATE: B.E.A., Inc.PH: (412) 249-4100 FAX: (412) 249-4101 10 A 100 Enterprise Drive Pittsburgh, PA 15275 www.beasensors.com 1 OF 1NTS GDM B STALLTORQUESWITCH (See Note #2)WHITE BLACK Motor Voltage (See Note #4) Tech Support NOTE: 1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE APPROACH SIDE SUPERSCAN'S 2 WHITE WIRES. INSTALL THE BLUE WIRE INTO PIN 6. 2.) MAGIC FORCE AUX. SWITCH #4 SHOULD OPEN AT APPROX. 65-70 DEGREES. FOR MAGIC SWING REFER TO INHIBIT SWITCH BEA PT# 10 SSINHL OR 10SSINHR. 3.) THE BODYGUARD RELAY OUTPUT FUNCTION MUST BE CHANGED TO #2. 4.) SHOWN LH,RH MAGIC SWING AND RH MAGIC FORCE FOR LH MAGIC FORCE REVERSE RED AND BLACK WIRES. 5.) DOOR CONTROL SW2 SWITCH BANK SET DIPSWITCH #1 TO THE OFF (TIMER) POSITION. (See Note #5) (See Note #1)RED/WHITE BROWN ORANGE GREEN YELLOW BODYGUARDSIZE: LEFT APPROACH SIDE LEFT SAFETY SIDE RIGHT SAFETY SIDE RIGHT APPROACH SIDEBLACK -- RED + DISCONNECT CABLE SUPERSCAN QUICK BLUE WHITE 115 VAC24 V POWER 2 COM 3 N.O. 4 N.C. 5 DATA - 6 DATA + 7 DK-1275.5079.08 20061129 Page 11 of 13 5 N/C 4 N/O 3 COM 2 PWR 1 PWR SHEET:SCALE: SUPERSCAN QUICK PARALLAX II SYSTEM Q-DISCONNECT TITLE: STANLEY MP CONTROL WITH LO-21P CONTROL STANLEY MP8 COMMON 7 SAFETY/STALL 6 AUX INPUT 5 12 VAC 4 12 VAC 3 SENSOR OP 2 OPERATE 1 COMMON80.0188 NTS 6 JUNE 2003CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: B.E.A., Inc.PH: (412) 249-4100 FAX: (412) 249-4101 11 A 100 Enterprise Drive Pittsburgh, PA 15275 DATE: www.beasensors.com 1 OF 1 GDM B LO-21PBROWN ORANGE RED/WHITE STALLTORQUESWITCH (See Note #2)WHITE BLACK Motor Voltage (See Note #4) ON SAFETY SIDEDISCONNECT CABLE Tech Support EAGLENOTE: 1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE APPROACH SIDE SUPERSCAN'S WHITE WIRE. INSTALL THE YELLOW WIRE INTO PIN 6. 2.) MAGIC FORCE AUX. SWITCH #4 SHOULD OPEN AT APPROX. 65-70 DEGREES. FOR MAGIC SWING REFER TO INHIBIT SWITCH BEA PT# 10 SSINHL OR 10SSINHR. 3.) THE BODYGUARD RELAY OUTPUT FUNCTION MUST BE CHANGED TO #2. 4.) SHOWN LH,RH MAGIC SWING AND RH MAGIC FORCE FOR LH MAGIC FORCE REVERSE RED AND BLACK WIRES. 5.) DOOR CONTROL SW2 SWITCH BANK SET DIPSWITCH #1 TO THE OFF (TIMER) POSITION. (See Note #5) (See Note #1) (See Note #1) (See Note #3)GREEN YELLOW 75.5079.08 20061129 Page 12 of 13 BLACK / WHITEDISCONNECT CABLE SUPERSCAN QUICK CONTROL BOX . 3.) DO NOT POWER ALL THE SENSORS FROM ONE MUST BE CHANGED TO #2. 2.) THE BODYGUARD RELAY OUTPUT FUNCTION 1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE NOTE: 80.0193 NTS 6 JUNE 2003CAGE CODE:DWG NO:FILE OF:DRAWN BY:REV: DATE: 12 A SCALE: EAGLELEFT APPROACH SIDELEFT SAFETY SIDERIGHT SAFETY SIDESIZE:POWER 1 POWER 2 COM 3 N.O. 4 N.C. 5 DATA - 6 DATA + 7 BODYGUARDDK-125 N/C 4 N/O 3 COM 2 PWR 1 PWR SHEET: WITH LO-21P PARALLAX II SYSTEM TITLE: BESAM CUP VER. 6.3,6.4 CONTROL 4 COM 5 P DET MAT 9 OFF 8 SYNC 10 0 VDC 11 SYNC 12 13 SWITCH 1 19 +18 VDC 17 +24 VDC 18 -24 VDC 14 SWITCH 2 CUP B.E.A., Inc.PH: (412) 249-4100 FAX: (412) 249-4101 100 Enterprise Drive Pittsburgh, PA 15275 www.beasensors.com 1 OF 1 3 I IMP 4 COM 5 P DET 9 MAT 8 OFF 10 SYNC 11 0 VDC 12 SYNC 13 SWITCH 1 14 SWITCH 2 19 +18 VDC 17 +24 VDC 18 -24 VDC LO-21P CUP SLAVE MASTER3 I IMP APPROACH SIDE SUPERSCAN'S 2 WHITE WIRES. INSTALL THE BLUE WIRE INTO PIN 6. DEGREES, 11= 5 DEGREES LESS THAN F10 SYNC CABLE DISCONNECT CABLE Q-DISCONNECT ON APPROACH SIDE+ BROWN - ORANGE WHITE RED/WHITE (See Note #1) (See Note #1) (See Note #2) RIGHT APPROACH SIDE BODYGUARDSIZE: + BROWN - ORANGE GREEN (See Note #1) (See Note #1) (See Note #2)DISCONNECT CABLE SUPERSCAN QUICK RED/WHITE RED + BLACK -- EAGLELEFT APPROACH SIDE LEFT SAFETY SIDE RIGHT SAFETY SIDE RIGHT APPROACH SIDEVIOLET GRAY WHITEPOWER 1 POWER 2 COM 3 N.O. 4 N.C. 5 DATA - 6 DATA + 7 DK-1275.5079.08 20061129 Page 13 of 13 5 N/C 4 N/O 3 COM 2 PWR 1 PWR SHEET:SCALE: 4 COM 5 P DET 9 MAT LOGIC OFF 8 SYNC 10 0 VDC 11 SYNC 12 13 SWITCH 1 19 +18 VDC 17 +24 VDC 18 -24 VDC 14 SWITCH 2 Q-DISCONNECT ON SAFETY SIDE WITH LO-21P PARALLAX II SYSTEM TITLE: BESAM CUP VER. 6.3,6.4 CONTROL CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: DATE: B.E.A., Inc.PH: (412) 249-4100 FAX: (412) 249-4101 13 A 100 Enterprise Drive Pittsburgh, PA 15275 www.beasensors.com 1 OF 1NTS 3 I IMP 4 COM 5 P DET 9 MAT 8 OFF 10 SYNC 11 0 VDC 12 SYNC 13 SWITCH 1 14 SWITCH 2 19 +18 VDC 17 +24 VDC 18 -24 VDC LO-21PBLACK / WHITE Tech Support CUP SLAVE CUP MASTER3 I IMPNOTE: 1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE APPROACH SIDE SUPERSCAN'S WHITE WIRE. INSTALL THE YELLOW WIRE INTO PIN 6. 2.) THE BODYGUARD RELAY OUTPUT FUNCTION MUST BE CHANGED TO #2. 3.) DO NOT POWER ALL THE SENSORS FROM ONE CONTROL BOX . 4.) ON BOTH CONTROLS SET PMD FUNCTIONS 20=b, 19=b, 18=00, 17=00, 14=a, 13=a, 12=65 DEGREES, 11= 5 DEGREES LESS THAN F10 5.) INHIBITING THE SAFETY SIDE SUPERSCAN (F12) SHOULD OCCUR AT APPROX. 65-75 DEGREES.SYNC CABLE DISCONNECT CABLE BLUE YELLOW
Also you can find more BEA manuals or manuals for other Power Tools.