75.5079.08 20061129 Page 9 of 13

BODYGUARD

DK-12
DATA + 7
DATA - 6
N.C. 5
N.O. 4
COM 3
POWER 2
POWER 1
5 N/C
4 N/O
3 COM
2 PWR
1 PWR
24 V
TRANSFORMER
115 VAC
HOLD
OPEN
OFF
SIZE:
SHEET:SCALE:

A

PH: (412) 249-4100 FAX: (412) 249-4101

B.E.A., Inc.

100 Enterprise Drive Pittsburgh, PA 15275
DATE:
www.beasensors.com
CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV:
1 OF 1
NTS
Tech Support
TITLE: BESAM 300/400 (ETIK2) WITH LO-21P
PARALLAX II SYSTEM Q-DISCONNECT
ON SAFETY SIDE
6 JUNE 2003
GDM B
AUTO
80.0186
BLACK
BROWN
WHITE
BLACK
RED
GREEN
BLACK
RED
BROWN
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
BLACK
WHITE
GREEN
RED

LO-21P

RED/WHITE
WHITE
BLUE

BESAM ETIK

CONTROL

HS LS HD
BLACK
WHITE
17 STALL INPUT
18 STALL INPUT
15 STALL INPUT
16 STALL INPUT
13 ACTIVATION
12 COMMON
11 SAFETY
10 COMMON
Common
N/O
N/C
Motor Voltage (See Note #6)
LEFT APPROACH SIDE LEFT SAFETY SIDE RIGHT SAFETY SIDE RIGHT APPROACH SIDE
EAGLE
RED +
BLACK --
YELLOW
YELLOW
RED
NOT USED NOT USED
NOT USED
NOT USED
SUPERSCAN QUICK
DISCONNECT CABLE
SUPERSCAN QUICK
DISCONNECT CABLE
Wire nut
BROWN
ORANGE
NOTE:
1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE
APPROACH SIDE SUPERSCAN'S WHITE WIRE.
INSTALL THE YELLOW WIRE INTO PIN 6.
2.) ON SAFETY SIDE SUPERSCAN MOVE GREEN WIRE
FROM PIN 5 TO PIN 4.
3.) B-SWITCH SHOULD CLOSE AT APPROX.
65-75 DEGREES.
4.) INSTALL A JUMPER BETWEEN PINS 17&18
5.) THE BODYGUARD RELAY OUTPUT FUNCTION
MUST BE CHANGED TO #2.
6.) RH MOTOR SHOWN, REVERSE LO-21P RED
AND BLACK WIRES FOR LH MOTOR.
(See Note #5)
(See Note #1)(See Note #2)(See Note #2)(See Note #1)
(See Note #4)
B-SWITCH
(See Note #3)
YELLOW
VIOLET
GRAY
BLACK / WHITE
YELLOW
GREEN