75.5079.08 20061129 Page 9 of 13
BODYGUARD
DK-12
DATA + 7
DATA - 6
N.C. 5
N.O. 4
COM 3
POWER 2
POWER 1
5 N/C
4 N/O
3 COM
2 PWR
1 PWR
24 V
TRANSFORMER
115 VAC
HOLD
OPEN
OFF
SIZE:
SHEET:SCALE:
A
PH: (412) 249-4100 FAX: (412) 249-4101
B.E.A., Inc.
100 Enterprise Drive Pittsburgh, PA 15275
DATE:
www.beasensors.com
CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV:
1 OF 1
NTS
Tech Support
TITLE: BESAM 300/400 (ETIK2) WITH LO-21P
PARALLAX II SYSTEM Q-DISCONNECT
ON SAFETY SIDE
6 JUNE 2003
GDM B
AUTO
80.0186
BLACK
BROWN
WHITE
BLACK
RED
GREEN
BLACK
RED
BROWN
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
BLACK
WHITE
GREEN
RED
LO-21P
RED/WHITE
WHITE
BLUE
BESAM ETIK
CONTROL
HS LS HD
BLACK
WHITE
17 STALL INPUT
18 STALL INPUT
15 STALL INPUT
16 STALL INPUT
13 ACTIVATION
12 COMMON
11 SAFETY
10 COMMON
Common
N/O
N/C
Motor Voltage (See Note #6)
LEFT APPROACH SIDE LEFT SAFETY SIDE RIGHT SAFETY SIDE RIGHT APPROACH SIDE
EAGLE
RED +
BLACK --
YELLOW
YELLOW
RED
NOT USED NOT USED
NOT USED
NOT USED