75.5079.08 20061129 Page 8 of 13

BODYGUARD

DK-12
DATA + 7
DATA - 6
N.C. 5
N.O. 4
COM 3
POWER 2
POWER 1
5 N/C
4 N/O
3 COM
2 PWR
1 PWR
24 V
TRANSFORMER
115 VAC
SIZE:
SHEET:SCALE:

A

PH: (412) 249-4100 FAX: (412) 249-4101

B.E.A., Inc.

100 Enterprise Drive Pittsburgh, PA 15275
DATE:
www.beasensors.com
CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV:
1 OF 1
NTS
Tech Support
TITLE: BESAM 300/400 (ETIK2) WITH LO-21P
PARALLAX II SYSTEM Q-DISCONNECT
ON APPROACH SIDE
6 JUNE 2003
GDM B
80.0185
WHITE
BLACK
RED
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
BLACK
RED

LO-21P

RED/WHITE
WHITE
GRAY
BLUE

BESAM ETIK

CONTROL

HS LS HD
BLACK
WHITE
17 STALL INPUT
18 STALL INPUT
15 STALL INPUT
16 STALL INPUT
13 ACTIVATION
12 COMMON
11 SAFETY
10 COMMON
Common
N/O
N/C
Motor Voltage (See Note #6)
LEFT APPROACH SIDE LEFT SAFETY SIDE RIGHT SAFETY SIDE RIGHT APPROACH SIDE
BROWN
WHITE
BROWN
RED
GREEN
BLACK
RED +
BLACK --
BLUE
RED
BLACK
GREEN
BLUE
EAGLE
NOT USED
NOT USEDNOT USED
NOT USED
NOTE:
1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE
APPROACH SIDE SUPERSCAN'S 2 WHITE WIRES.
INSTALL THE BLUE WIRE INTO PIN 6.
2.) ON SAFETY SIDE SUPERSCANS MOVE BROWN WIRE
FROM PIN 5 TO PIN 4.
3.) B-SWITCH SHOULD CLOSE AT APPROX.
65-70 DEGREES.
4.) INSTALL A JUMPER BETWEEN PINS 17&18
5.) THE BODYGUARD RELAY OUTPUT FUNCTION
MUST BE CHANGED TO #2.
6.) RH MOTOR SHOWN, REVERSE LO-21P RED
AND BLACK WIRES FOR LH MOTOR.
OFF
AUTO
HOLD
OPEN
SUPERSCAN QUICK
DISCONNECT CABLE
SUPERSCAN QUICK
DISCONNECT CABLE
BROWN
ORANGE
Wire nut
(See Note #1)
(See Note #1)
(See Note #5)
(See Note #2)(See Note #2)
(See Note #4)
B-SWITCH
(See Note #3)
VIOLET
BLACK / WHITE
GREEN
YELLOW