ELECTRICAL INSTALLATION – OPTION 1 –

STANDARD WIRING

WIRE CONNECTIONS

Black

Motor Input -

Red

Motor Input +

Purple

Bodyguard COM. Pin 3

White

Bodyguard Data (-) Pin 6

Black / White

Activation Sensor COM.

Orange

Power input / 12-24 VAC/VDC ( - )

Gray

Bodyguard N.O. Pin 4

Red / White

Bodyguard Data (+) Pin 7 & Activation Sensor N.O.

Brown

Power input / 12-24 VAC/VDC (+)

Green

Door Control Common

Blue

Door Control Activation

Yellow

Door Control safety

LO-21P WIRING DIAGRAMS:

STANDARD WIRING

The wiring shown below may be used on most models of operators. See wiring diagrams at back of this manual for specific diagrams.

BODYGUARD

NOTE: Bodyguard MUST be programmed to a Relay Output value of 2. Default is 1.

DATA + 7

DATA - 6

N.C. 5

N.O. 4

COM 3

POWER 2

POWER 1

24 V

115 VAC TRANSFORMER

brown

 

orange

 

purple

 

gray

 

white

 

red/white

Blk/white

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

LO-21P

 

 

 

 

 

 

 

 

 

 

 

 

LO-21P DIPSWITCH SETTINGS:

#1 THROUGH #5 - SET FOR

 

 

REQUIRED LOCKOUT TIME

 

 

#6 ON, #7 OFF, #8 ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5

AUTO

 

 

OFF

 

 

HOLD

 

 

 

MOTOR

OPERATOR

 

 

 

+

 

red

-

 

black

 

Door Control

yellow

 

SAFETY

 

green

 

COMMON

 

blue

 

ACTIVATION

 

STALL

 

 

 

Contacts to open

 

 

at desired point of

 

 

inhibiting

1 2 3 4 5 6 7 8

8 7 6 5 4 3 2 1

Approach SuperScan

Stall SuperScan

 

(Swing Side)

EAGLE

NOTES:

For pairs of doors, wire the additional SuperScans the same as shown above.

For the inhibit function, operator mounted auxiliary switches may be used – dry contacts only.

Bodyguard must be programmed to a relay value of 2.

75.5079.08 20061129

Page 2 of 13

Page 2
Image 2
BEA technical specifications LO-21P Wiring Diagrams, Operator