75.5079.08 20061129 Page 12 of 13

BODYGUARD

DK-12

DATA + 7
DATA - 6
N.C. 5
N.O. 4
COM 3
POWER 2
POWER 1
5 N/C
4 N/O
3 COM
2 PWR
1 PWR
SIZE:
SHEET:
SCALE:

A

PH: (412) 249-4100 FAX: (412) 249-4101

B.E.A., Inc.

100 Enterprise Drive Pittsburgh, PA 15275
DATE:
www.beasensors.com
CAGE CODE:DWG NO:FILE OF:DRAWN BY:REV:
1 OF 1
NTS 6 JUNE 2003
GDM A
80.0193
RED
BLACK
WHITE
BLACK
RED
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
8 POWER
7 POWER
6 COM
5 N.O.
4 N.C.
3 INHIBIT +
2 INHIBIT GND
1 BLANK
BLACK
RED

LO-21P

GRAY
LEFT APPROACH SIDELEFT SAFETY SIDERIGHT SAFETY SIDE
WHITE
RED
GREEN
BLACK
BROWN
BROWN
BLUE
BLUE
GREEN

EAGLE

HOLD OPEN
OFF
AUTO
Tech Support
NOT USED
NOT USEDNOT USEDNOT USED
BLACK --
RED +
18 -24 VDC
17 +24 VDC
19 +18 VDC
14 SWITCH 2
13 SWITCH 1
12 SYNC
11 0 VDC
10 SYNC
8 OFF
9 MAT
5 P DET
4 COM
3 I IMP

CUP

SLAVE

CUP

MASTER

14 SWITCH 2
18 -24 VDC
17 +24 VDC
19 +18 VDC
13 SWITCH 1
SYNC 12
0 VDC 11
SYNC 10
OFF 8
MAT 9
5 P DET
4 COM
3 I IMP
NOTE:
1.) REMOVE FROM PIN 6 AND PLACE A WIRE NUT ON THE
APPROACH SIDE SUPERSCAN'S 2 WHITE WIRES.
INSTALL THE BLUE WIRE INTO PIN 6.
2.) THE BODYGUARD RELAY OUTPUT FUNCTION
MUST BE CHANGED TO #2.
3.) DO NOT POWER ALL THE SENSORS FROM ONE
CONTROL BOX .
4.) ON BOTH CONTROLS SET PMD FUNCTIONS
20=b, 19=b, 18=00, 17=00, 14=a, 13= a, 12=65
DEGREES, 11= 5 DEGREES LESS THAN F10
5.) INHIBITING THE SAFETY SIDE SUPERSCAN (F12)
SHOULD OCCUR AT APPROX. 65-75 DEGREES.
SYNC CABLE
SUPERSCAN QUICK
DISCONNECT CABLE
SUPERSCAN QUICK
DISCONNECT CABLE
TITLE: BESAM CUP VER. 6.3,6.4 CONTROL
WITH LO-21P PARALLAX II SYSTEM
Q-DISCONNECT ON APPROACH SIDE
+ BROWN
- ORANGE
WHITE
RED/WHITE
(See Note #1)
(See Note #1)
(See Note #2)
RIGHT APPROACH SIDE
BLUE
VIOLET
BLACK / WHITE
GREEN
YELLOW