SETUP INSTRUCTION Cont.

7.Adjustment is necessary to configure the dipswitches to obtain the correct lock out time delay. To set the dipswitches( 1 through 5) for lock out time, perform the following:

‰Activate the door to the open position.

‰Time the overall door closing cycle

‰Configure the dip switches according to the chart on Page 4 for the lockout time that is required

‰Activate the door again to the open position

‰Stand outside of the Bodyguard detection pattern, and while the door is closing, observe the red LED on the Bodyguard

‰The red LED on the Bodyguard should NOT illuminate during the closing cycle. If it does, it is probably seeing the door at the very last degree or two of door closing, which would indicate that the lock out time needs to be slightly increased.

‰Reconfigure the dipswitches to add 1 second of lock out time.

‰When the lock out time is correct. The red LED will not illuminate during the entire closing cycle of the door.

8.The last test is to insure that the Bodyguard detects an object as soon as the door has stopped closing. Simply allow the doors to begin closing, and step in behind the doors, into the Bodyguards field of detection. The red LED shall illuminate and remain on at the Bodyguard, and at the LO-21P, as soon as the door reaches the fully closed position, provided that an object remains in the Bodyguard’s detection field.

9.Set the dipswitches according to the chart below to achieve the desired lockout time. The total lockout time is the sum total of the dipswitches that are in the ON position. For easy reference, use the timetables below. Default time is 7 seconds (times are approximate).

Dipswitch # Time Delay (seconds)

11

22

34

48

516

DIPSWITCH 6, 7 and 8

OPERATION

Time

dip 1

dip 2

dip 3

dip 4

dip 5

Delay

1 sec

2 sec

4 sec

8 sec

16 sec

(sec)

 

 

 

 

 

1

on

off

off

off

off

2

off

on

off

off

off

3

on

on

off

off

off

 

 

 

 

 

 

4

off

off

on

off

off

5

on

off

on

off

off

6

off

on

on

off

off

 

 

 

 

 

 

7

on

on

on

off

off

8

off

off

off

on

off

9

on

off

off

on

off

 

 

 

 

 

 

10

off

on

off

on

off

11

on

on

off

on

off

12

off

off

on

on

off

 

 

 

 

 

 

13

on

off

on

on

off

14

off

on

on

on

off

15

on

on

on

on

off

 

 

 

 

 

 

16

off

off

off

off

on

Time

dip 1

dip 2

dip 3

dip 4

dip 5

Delay

1 sec

2 sec

4 sec

8 sec

16 sec

(sec)

 

 

 

 

 

17

on

off

off

off

on

18

off

on

off

off

on

19

on

on

off

off

on

 

 

 

 

 

 

20

off

off

on

off

on

21

on

off

on

off

on

22

off

on

on

off

on

 

 

 

 

 

 

23

on

on

on

off

on

24

off

off

off

on

on

25

on

off

off

on

on

 

 

 

 

 

 

26

off

on

off

on

on

27

on

on

off

on

on

28

off

off

on

on

on

 

 

 

 

 

 

29

on

off

on

on

on

30

off

on

on

on

on

31

on

on

on

on

on

 

 

 

 

 

 

Dipswitch 6 Position

ON (Default)

OFF

Dipswitch 7 and 8

Position

7 OFF / 8 ON (Default)

7 ON / 8 OFF

Description of Performance

The LO21P expects to see voltage coming in at the red and black wire while the door is in the Open position. Typical for DC motors.

The LO21P expects to see voltage coming in at the red and black wire while the door is in the Closed position.

Description of Performance

The LO21P CLOSES the Safety circuit (yellow wire) upon a Bodyguard Detection during the door closed position

The LO21P OPENS the Safety circuit (yellow wire) upon a Bodyguard Detection during the door closed position

75.5079.08 20061129

Page 6 of 13

Page 6
Image 6
BEA LO-21P technical specifications Setup Instruction, Dipswitch # Time Delay seconds Dipswitch 6, 7, Operation